Phone +420 774 723 123 Cart · 0 · empty

Signal lamps and LED strips

Signalling elements

Subcategories

Filters
Found 62 products
OUR TIP IN STOCK

CP0B0XB, EMAS, LED indicator white

Cat. no.: CP0B0XB

CP0B0XB EMAS - LED indicator light, white, 100-230V AC, 22 mm. Technical specifications, use and selection of variants.

In stock 5 or more pcs
6,72 €
excl. VAT · 8,13 € incl. VAT
OUR TIP IN STOCK

MBZX220S, EMAS, panel horn with interrupted tone, 230VAC

Cat. no.: MBZX220S

MBZX220S EMAS - panel acoustic / light signalling, black, 230VAC, 22 mm. Technical specifications, use and selection of variants.

In stock 5 or more pcs
7,12 €
excl. VAT · 8,61 € incl. VAT
−3 % OUR TIP IN STOCK

MBZS220S, EMAS, panel horn with interrupted tone and light, 230VAC

Cat. no.: MBZS220S

MBZS220S EMAS - panel acoustic / light signalling, red, 230VAC, 22 mm. Technical specifications, use and selection of variants.

In stock 5 or more pcs
7,34 € 7,57 €
excl. VAT · 8,88 € incl. VAT
OUR TIP IN STOCK

LED strip RGBW-24, TECHNOLINE, four-colour LED strip RGBW, 24VDC

Cat. no.: LED strip RGBW-24

LED strip RGBW-24 TECHNOLINE: four-colour 24VDC LED strip - red, green, blue and white 4000K. Common cathode, 60 LED / m, SMD5050, IP20.

In stock 5 or more pcs
9,93 €
excl. VAT · 12,01 € incl. VAT
−3 % OUR TIP

D090YXY, EMAS, LED indicator green

Cat. no.: D090YXY

D090YXY EMAS - LED indicator light, green, 12-24V AC / DC, 16 mm. Technical specifications, use and selection of variants.

On request
3,55 € 3,66 €
excl. VAT · 4,30 € incl. VAT
OUR TIP

D050YXB, EMAS, LED indicator white

Cat. no.: D050YXB

D050YXB EMAS - LED indicator light, white, 12- 24V AC / DC, 16 mm. Technical specifications, use and selection of variants.

On request
3,66 €
excl. VAT · 4,43 € incl. VAT
OUR TIP

D070YXM, EMAS, LED indicator blue

Cat. no.: D070YXM

D070YXM EMAS - LED indicator, blue, 12- 24V AC / DC, 16 mm. Technical specifications, use and selection of variants.

On request
3,66 €
excl. VAT · 4,43 € incl. VAT
OUR TIP

D050KXB, EMAS, LED indicator white

Cat. no.: D050KXB

D050KXB EMAS - LED indicator light, white, 12- 24V AC / DC, 16 mm. Technical specifications, use and selection of variants.

On request
3,70 €
excl. VAT · 4,48 € incl. VAT
OUR TIP

H090XY, EMAS, LED indicator green, 30 mm, 12-30 V AC / DC, IP50

Cat. no.: H090XY

H090XY EMAS - LED indicator light, green, 12-30V AC / DC, 30 mm. Technical specifications, use and selection of variants.

On request
4,29 €
excl. VAT · 5,19 € incl. VAT
OUR TIP

MBZX024S, EMAS, panel horn

Cat. no.: MBZX024S

MBZX024S EMAS - panel acoustic / light signalling, black, 24V AC / DC, 22 mm. Technical specifications, use and selection of variants.

On request
6,84 €
excl. VAT · 8,28 € incl. VAT
OUR TIP

MBZS024S, EMAS, panel horn

Cat. no.: MBZS024S

MBZS024S EMAS - panel acoustic / light signalling, red, 24V AC / DC, 22 mm. Technical specifications, use and selection of variants.

On request
7,34 €
excl. VAT · 8,88 € incl. VAT
−3 % OUR TIP

AD16-22W/G23, APT, Signal Cross, Red + Green

Cat. no.: AD16-22W/G23

AD16-22W/G23 APT - industrial automation component, red, 24 V AC / DC, 22 mm. Technical specifications, use and selection of variants.

On request
7,88 € 8,12 €
excl. VAT · 9,53 € incl. VAT

Prices include the recycling fee.

Signal lamps and LED strips

The indicator light informs the operator about the condition of the device; the LED strip creates a continuous light line. When selecting, start with the purpose: do you need to distinguish the state of individual circuits on a panel, display the status of a workshop, or illuminate a specific space? The same light colour does not necessarily mean the same electrical connection or suitability for a given application.

This guide explains selecting signals for the distribution board and control panel, and basic dimensioning of LED strip power. The specific voltage, dimensions, cover, and installation conditions are always determined by the documentation of the selected order variant.

Quick orientation in the menu

How to select panel indicator light

1. Determine the exact power supply and execution of the light element

Describe the voltage and AC, DC, or AC/DC designation from the project and the control documentation. The information '24 V' without specifying the type of voltage is not a complete specification. A variant intended only for DC cannot be automatically replaced with AC/DC; for single-phase operation, verify the specified polarity. A control with an integrated power supply, a separate light module, and a flat LED diode are different components.

The difference can be hidden in the short order code suffix. For example, manufacturer EMAS in the S series distinguishes between voltage and lighting implementations; therefore, parameters from one variant cannot be transferred to the entire series. When replacing an old signal, compare the entire code, not just the similarity of the terminal connector. See overview of S series variants from manufacturer EMAS.

2. Check mounting hole and space behind panel

The mounting diameter is not the same as the outer diameter of the terminal frame. The drawing must match the opening in the panel, the thickness of the material, the method of fixing, and the available depth. Also consider space for connecting cables and servicing. Two signal lights with the same mounting diameter may not be mechanically interchangeable without further control.

For industrial installation, verify if you are ordering a complete assembly, just the head, holder, or light block. The specification includes the type of connection: for example, screws, connector, or pulled cables according to the specific product.

3. Design the unambiguous importance of signalling

Determine the colour, permanent lighting, and any blinking based on the device function and machine documentation. On one panel, maintain a consistent meaning of statuses and provide a clear description. A good design test sounds like: does the new operator understand that the control means power presence, start command, actual operation, or fault? This information cannot be replaced.

Consider readability from the actual operating location, surrounding lighting, and viewing angle. A signalisation control does not confirm the safe state of the machine and does not replace the safety function designed for the given risk.

4. Check environment and electrical continuity

In the technical data sheet, look for operating temperature, declared cover, and conditions under which it applies. Distinguish requirements for the panel face and space for the enclosure. Outdoor operation, washing, oiling, or chemical environments cannot be resolved by just looking at the control appearance.

When controlling from PLC, compare the control voltage and supply with the output module parameters and its wiring diagram. It is not enough that both elements show 24 V. Also verify the output type, common potential, and behaviour in the off state. Wiring must follow the documentation of both devices.

Power supply LED strip: what CV and CC mean

CV (constant voltage) means a constant voltage source; CC (constant current) means a constant current source. A standard strip with its own current limit, for example for 24 V DC, requires corresponding voltage supply. The LED circuit itself without such a limit may require a current driver. The construction and documentation determine the load, not the general 'LED power source' designation.

For the current driver, check the specified current and output voltage range in which it operates. For the voltage source, check the output voltage and available current or power. At the same time, respect temperature conditions and any reduction of the source's permissible power at higher temperatures. Technical background explains LED wizard from MEAN WELL.

Calculation of power: illustrative example, not product parameter

Assume the band prescribed for 24 V DC, length 3 m and power input 9,6 W / m. This is a model input to explain the calculation, not a specification of all bands in this category.

  • Tape power: P = 3 × 9,6 = 28,8 W.
  • Current at the specified voltage: I = P / U = 28,8 / 24 = 1,2 A.
  • If the same source supplies additional loads, include their current consumption and any control electronics.

The calculated 28,8 W is the power of the specified strip, not an automatic final demand for the rated power of the source. The choice of a specific source must consider the tolerance of the supply, cooling conditions, and operating reserve according to the documentation. One universal reserve percentage does not solve all installations.

Lead length, voltage loss and dimming

For the base estimate: ΔU = I × R, where R is the total resistance of the current path. For example, with a current of 1,2 A and a total resistance of the forward and return paths 0,5 Ω, a voltage drop of 0,6 V occurs, i.e., 2,5 % of 24 V. This simplified calculation does not include the distribution of the supply along the strip. However, it shows why it is necessary to consider not just the source power, but also the wiring, connections, and maximum length of the segment specified by the manufacturer.

For mounting, the strip must be compatible, the power section of the regulator, and its control. PWM on the power output is not the same as the source input control. MEAN WELL for commonly limited strips describes the advantages of a suitable PWM output over simply changing the current amplitude; at the same time, it depends on the combination of load and driver. Details are provided application article on dimming LED stripsTherefore, select the method of regulation according to specific technical papers, not just the word "dimmable."

Common problems and what to check

  • The indicator light shall not be lit: verify the correct voltage variant, the type of power supply and the conformity of the connection with the documentation.
  • The indicator after the command to turn off the light is weak: One option is inconsistency between sensitive load and output behaviour in the off state. Assessment belongs to the documentation of the specific combination; do not add a randomly chosen resistor as a universal solution.
  • The end of the tape is different from the beginning: Check the length of section, line and connection points according to installation instructions. The cause may not be in LED itself.
  • The light flashes or turns off in a jump when dimming: check the permitted load, type of regulation and compatibility of individual parts.

What to send for selection or replacement

For the control, prepare the full order code or readable label, AC/DC voltage, required colour, opening dimensions, panel thickness, connection, and environmental conditions. For LED strips, add length, voltage, power per metre, regulation method, and lighting or signalisation requirement. With these data, you can solve selection of components without estimating unknown parameters.

Frequently asked questions

Is every LED signal a indicator light?

No. The signal marking describes the function, not the lamp technology. Verify the specific version in the technical sheet.

Does 22 mm mean that any 22 mm indicator light can be used?

No. The mounting dimension is only one condition. Compare fastening, depth, panel thickness, electrical parameters and delivery range.

Is it enough for LED strip to select the source by watts?

No. First, the mode of power supply and voltage or current must be agreed. Only then is power, temperature, regulation and installation conditions assessed.

The guide is for selecting components and does not replace the project or specific product manual. Installation and electrical verification must be carried out by a professionally skilled person with the device safely secured. Parameters of one variant cannot be generalised to the entire category.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.