P1BOS, EMAS, control box / box
P1BOS EMAS - control box / box. Technical specifications, use, assembly and selection of the correct variant.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Empty and mounted boxes, consoles, contacts and assembly space.
P1BOS EMAS - control box / box. Technical specifications, use, assembly and selection of the correct variant.
P1EBOS EMAS - control box / box, yellow. Technical specifications, use, assembly and selection of the correct variant.
P2BOS EMAS - control box / box. Technical specifications, use, installation and selection of the correct variant.
P3BOS EMAS - control box / box. Technical specifications, use, assembly and selection of the correct variant.
P3ECBOS EMAS - control box / box, yellow. Technical specifications, use, assembly and selection of the correct variant.
P1C300DY EMAS - control box / box, green, 1 NO. Technical specifications, use, assembly and selection of the correct variant.
P4BOS EMAS - control box / box. Technical specifications, use, assembly and selection of the correct variant.
P6BOS EMAS - control box / box. Technical specifications, use, assembly and selection of the correct variant.
P1C300M-72H EMAS - control box / box, black, 1 NO. Technical specifications, use, assembly and selection of the correct variant.
PA3E40K20P1 EMAS - control box / box, red, 1 NO + 1 NC. Technical specifications, use, installation and selection of the correct variant.
KONZOLE-AL-5D TECHNOLINE - aluminum control console. Technical specifications, use, installation and selection of the correct variant.
KONZOLE-AL-7D TECHNOLINE - aluminium control console. Technical specifications, use, installation and selection of the correct variant.
KONZOLE-AL-9D TECHNOLINE - aluminium control console. Technical specifications, use, installation and selection of the correct variant.
Prices include the recycling fee.
The button box forms a local control station: it holds elements in an accessible position, provides space for their rear part, and allows the wiring to be organized. The number of openings is not the only decisive factor. Before selecting, determine the functions of the controls, the required contacts, the method of fixing, and the place where the wires will be connected.
The offer includes boxes of series P... BOS, mounted P1C300DY and P1C300M-72H, set PA3E40K20P1 and console KONZOLE-AL-5D, KONZOLE-AL-7D and KONZOLE-AL-9D.
P1BOS according to the manufacturer is an empty box with one hole for control Ø 22 mm.
For mounted P1C300DY EMAS technical certificate Specifies BDDY + C3BK assembly with one switch contact.
PA3E40K20P1 combines a stop actuator, another button element and socket. KONZOLE-AL-7D is listed as an unequipped seven-door console.
The empty case is selected together with individual devices. For an assembled assembly, first compare the supplied functions with the project; the presence of a button does not mean that all wires, screws, or lighting elements needed for your connection are ready.
The front part accepts a press or turn and transfers the mechanical movement to the contact block. The NO push button is disconnected in the defined idle state, while the NC push button is engaged. When building, describe the idle state of each function and its change during operation. The latched button remains in the position, while the returnable one returns to it upon release.
The lighting part is a separate electrical function. Its voltage does not have to match the voltage of the engaged contact. The green button also automatically does not confirm the machine's operation: the check can be connected to the command, to the auxiliary contact of the connector, or to another feedback. Choose the meaning that the operator actually needs to know.
For their own installation they follow Button switches and Control device accessoriesCheck the diameter and shape of the hole, the thickness of the panel, the mounting adapter, the rear depth and the width of the contact blocks.
Include space for bringing wires to the screws without a sharp bend. The cable harness must not interfere with the space of the contact block and the open opening must not pull on the connections. Multiple contacts on one button may require greater depth, although no additional opening will be added on the front side.
Consider a purely model box with a usable internal depth of 65 mm. The back part of the selected button takes up 40 mm, the space for wire bending is 20 mm, and the mounting reserve is 10 mm. The total requirement is 40 + 20 + 10 = 70 mm, which is 5 mm more than is available. The box does not meet the requirements, even though it has the correct number of openings. These values are hypothetical; evaluate the actual assembly according to the drawings, not the external depth of the box.
Draw the wiring diagram separately for each contact and lighting circuit. Assign numbers to the screws and label the wires. Verify that the screw accepts the selected twisted pair wire with a screw or without one and allows any connection of multiple wires. Manipulating the opening must be possible without disturbing the contacts; the service loop must not interfere with the tightening.
The required protection against the environment must be provided by the complete assembled assembly: the cabinet, buttons, covers, tightening, and cable inputs. Choose the wiring according to the actual cable diameter and mounting screw. For a metal console, also consider protective connections according to the installation execution. An unsuitable additional opening can invalidate the correctly selected lid.
When selecting a larger control point, it can be connected to KONZOLE-AL-7DArrange the elements so that the descriptions are readable and gloves do not accidentally press an adjacent button. When installing the switch, check the mechanical securing, the function of each contact, and the conformity of the labeling with the diagram.
Verify the scope of supply according to the specific variant. Installing the device is not the same as complete internal wiring and connecting cables. Pre-determine which work should be part of the station assembly.
Only if the electrical parameters of the contact and the load characteristic match. In a normal control circuit, the button often only passes the command to the next push button. The current load cannot be derived from the size of the box.
The shape itself or the yellow color of the box is not enough. The properties of the button, contacts, and the entire safety circuit depend on it. Propose and verify the function of emergency stop as part of the machine's safety solution.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.