S100K, EMAS, red signal indicator
S100K EMAS - indicator light, red, 230V AC. Technical specifications, use and selection of variants.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Signalling elements
S100K EMAS - indicator light, red, 230V AC. Technical specifications, use and selection of variants.
S100Y EMAS - signalling indicator light, green, 230V AC. Technical specifications, use and selection of variants.
S100M EMAS - signalling indicator light, blue, 230V AC. Technical specifications, use and selection of variants.
S100B EMAS - signalling indicator light, white, 230V AC. Technical specifications, use and selection of variants.
S100S EMAS - signalling indicator light, yellow, 230V AC. Technical specifications, use and selection of variants.
S100LK -50 EMAS - indicator light, red, 230V AC, 0,5 m. Technical specifications, use and selection of variants.
S100LM-50 EMAS - signalling indicator light, blue, 230V AC, 0,5 m. Technical specifications, use and selection of variants.
S100LS-50 EMAS - signalling indicator light, yellow, 230V AC. Technical specifications, use and selection of variants.
S100LY50 EMAS - signalling indicator light, green, 230V AC, 0,5 m. Technical specifications, use and selection of variants.
S140M2 EMAS - signalling indicator light, blue, 24V AC / DC. Technical specifications, use and selection of variants.
S140B2 EMAS - indicator light, white, 24V AC / DC. Technical specifications, use and selection of variants.
S140K2 EMAS - indicator light, red, 24V AC / DC. Technical specifications, use and selection of variants.
S140Y2 EMAS - signalling indicator light, green, 24V AC / DC. Technical specifications, use and selection of variants.
S140S2 EMAS - indicator light, yellow, 24V AC / DC. Technical specifications, use and selection of variants.
AD16-22W / N31 APT - signalling element, red, 230V AC. Technical specifications, use and selection of variants.
AD16-22WF / D31 APT - component of industrial automation, red, 230V AC, 22 mm. Technical specifications, use and selection of variants.
D060DXK EMAS - LED indicator light, red, 12-24V AC / DC, 16 mm. Technical specifications, use and selection of variants.
D080DXS EMAS - LED indicator light, yellow, 12- 24V AC / DC, 16 mm. Technical specifications, use and selection of variants.
D060YXK EMAS - LED indicator light, red, 12-24V AC / DC, 16 mm. Technical specifications, use and selection of variants.
D080YXS EMAS - LED indicator light, yellow, 12- 24V AC / DC, 16 mm. Technical specifications, use and selection of variants.
D060KXK EMAS - LED indicator light, red, 12-24V AC / DC, 16 mm. Technical specifications, use and selection of variants.
D090KXY EMAS - LED indicator light, green, 12- 24V AC / DC, 16 mm. Technical specifications, use and selection of variants.
D070KXM EMAS - LED indicator, blue, 12-24V AC / DC, 16 mm. Technical specifications, use and selection of variants.
D080KXS EMAS - LED indicator light, yellow, 12- 24V AC / DC, 16 mm. Technical specifications, use and selection of variants.
D050DXB EMAS - LED indicator light, white, 12- 24V AC / DC, 16 mm. Technical specifications, use and selection of variants.
Prices include the recycling fee.
The indicator light informs the operator about the condition of the device; the LED strip creates a continuous light line. When selecting, start with the purpose: do you need to distinguish the state of individual circuits on a panel, display the status of a workshop, or illuminate a specific space? The same light colour does not necessarily mean the same electrical connection or suitability for a given application.
This guide explains selecting signals for the distribution board and control panel, and basic dimensioning of LED strip power. The specific voltage, dimensions, cover, and installation conditions are always determined by the documentation of the selected order variant.
Describe the voltage and AC, DC, or AC/DC designation from the project and the control documentation. The information '24 V' without specifying the type of voltage is not a complete specification. A variant intended only for DC cannot be automatically replaced with AC/DC; for single-phase operation, verify the specified polarity. A control with an integrated power supply, a separate light module, and a flat LED diode are different components.
The difference can be hidden in the short order code suffix. For example, manufacturer EMAS in the S series distinguishes between voltage and lighting implementations; therefore, parameters from one variant cannot be transferred to the entire series. When replacing an old signal, compare the entire code, not just the similarity of the terminal connector. See overview of S series variants from manufacturer EMAS.
The mounting diameter is not the same as the outer diameter of the terminal frame. The drawing must match the opening in the panel, the thickness of the material, the method of fixing, and the available depth. Also consider space for connecting cables and servicing. Two signal lights with the same mounting diameter may not be mechanically interchangeable without further control.
For industrial installation, verify if you are ordering a complete assembly, just the head, holder, or light block. The specification includes the type of connection: for example, screws, connector, or pulled cables according to the specific product.
Determine the colour, permanent lighting, and any blinking based on the device function and machine documentation. On one panel, maintain a consistent meaning of statuses and provide a clear description. A good design test sounds like: does the new operator understand that the control means power presence, start command, actual operation, or fault? This information cannot be replaced.
Consider readability from the actual operating location, surrounding lighting, and viewing angle. A signalisation control does not confirm the safe state of the machine and does not replace the safety function designed for the given risk.
In the technical data sheet, look for operating temperature, declared cover, and conditions under which it applies. Distinguish requirements for the panel face and space for the enclosure. Outdoor operation, washing, oiling, or chemical environments cannot be resolved by just looking at the control appearance.
When controlling from PLC, compare the control voltage and supply with the output module parameters and its wiring diagram. It is not enough that both elements show 24 V. Also verify the output type, common potential, and behaviour in the off state. Wiring must follow the documentation of both devices.
CV (constant voltage) means a constant voltage source; CC (constant current) means a constant current source. A standard strip with its own current limit, for example for 24 V DC, requires corresponding voltage supply. The LED circuit itself without such a limit may require a current driver. The construction and documentation determine the load, not the general 'LED power source' designation.
For the current driver, check the specified current and output voltage range in which it operates. For the voltage source, check the output voltage and available current or power. At the same time, respect temperature conditions and any reduction of the source's permissible power at higher temperatures. Technical background explains LED wizard from MEAN WELL.
Assume the band prescribed for 24 V DC, length 3 m and power input 9,6 W / m. This is a model input to explain the calculation, not a specification of all bands in this category.
The calculated 28,8 W is the power of the specified strip, not an automatic final demand for the rated power of the source. The choice of a specific source must consider the tolerance of the supply, cooling conditions, and operating reserve according to the documentation. One universal reserve percentage does not solve all installations.
For the base estimate: ΔU = I × R, where R is the total resistance of the current path. For example, with a current of 1,2 A and a total resistance of the forward and return paths 0,5 Ω, a voltage drop of 0,6 V occurs, i.e., 2,5 % of 24 V. This simplified calculation does not include the distribution of the supply along the strip. However, it shows why it is necessary to consider not just the source power, but also the wiring, connections, and maximum length of the segment specified by the manufacturer.
For mounting, the strip must be compatible, the power section of the regulator, and its control. PWM on the power output is not the same as the source input control. MEAN WELL for commonly limited strips describes the advantages of a suitable PWM output over simply changing the current amplitude; at the same time, it depends on the combination of load and driver. Details are provided application article on dimming LED stripsTherefore, select the method of regulation according to specific technical papers, not just the word "dimmable."
For the control, prepare the full order code or readable label, AC/DC voltage, required colour, opening dimensions, panel thickness, connection, and environmental conditions. For LED strips, add length, voltage, power per metre, regulation method, and lighting or signalisation requirement. With these data, you can solve selection of components without estimating unknown parameters.
No. The signal marking describes the function, not the lamp technology. Verify the specific version in the technical sheet.
No. The mounting dimension is only one condition. Compare fastening, depth, panel thickness, electrical parameters and delivery range.
No. First, the mode of power supply and voltage or current must be agreed. Only then is power, temperature, regulation and installation conditions assessed.
The guide is for selecting components and does not replace the project or specific product manual. Installation and electrical verification must be carried out by a professionally skilled person with the device safely secured. Parameters of one variant cannot be generalised to the entire category.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.