Indicator lightss, mounting 30 mm

LED signals of EMAS series H for mounting hole 30 mm.

Filters
Found 5 products
OUR TIP IN STOCK

H060XK, EMAS, LED indicator red 30 mm, 12-30 V AC / DC, IP50

Cat. no.: H060XK

H060XK EMAS - LED indicator light, red, 12-30V AC / DC, 30 mm. Technical specifications, use and selection of variants.

In stock 5 or more pcs
4,29 €
excl. VAT · 5,19 € incl. VAT
OUR TIP IN STOCK

H050XB, EMAS, LED indicator white 30 mm, 12-30 V AC / DC, IP50

Cat. no.: H050XB

H050XB EMAS - LED indicator light, white, 12-30V AC / DC, 30 mm. Technical specifications, use and selection of variants.

In stock 5 or more pcs
4,29 €
excl. VAT · 5,19 € incl. VAT
OUR TIP IN STOCK

H070XM, EMAS, LED indicator blue, 30 mm, 12-30 V AC / DC, IP50

Cat. no.: H070XM

H070XM EMAS - LED indicator light, blue, 12-30V AC / DC, 30 mm. Technical specifications, use and selection of variants.

In stock 5 or more pcs
4,29 €
excl. VAT · 5,19 € incl. VAT
OUR TIP IN STOCK

H080XS, EMAS, LED indicator yellow, 30 mm, 12-30 V AC / DC, IP50

Cat. no.: H080XS

H080XS EMAS - LED indicator light, yellow, 12-30V AC / DC, 30 mm. Technical specifications, use and selection of variants.

In stock 5 or more pcs
4,29 €
excl. VAT · 5,19 € incl. VAT
OUR TIP

H090XY, EMAS, LED indicator green, 30 mm, 12-30 V AC / DC, IP50

Cat. no.: H090XY

H090XY EMAS - LED indicator light, green, 12-30V AC / DC, 30 mm. Technical specifications, use and selection of variants.

On request
4,29 €
excl. VAT · 5,19 € incl. VAT

Prices include the recycling fee.

Indicator lightss, mounting 30 mm

For mounting hole 30 mm, select according to the whole assembly: front part, mounting, light block and electrical connection. The larger mounting dimension itself does not guarantee higher cover, different voltage resistance or better visibility in each application.

LED indicator light EMAS H series

In this category, the variants H050XB, H060XK, H070XM, H080XS, and H090XY are available in white, red, blue, yellow, and green. When choosing, keep the entire code; the initial series designation H at the beginning is not a complete electrical specification.

For model H050XB manufacturer presents white LED, diameter 30 mm, power supply 12-30 V AC / DC and IP50. technical page EMAS for H050XBThese data do not mean that any H-series product has the same voltage or light block.

Installation dimension, front dimension and real visibility

The 30 mm designation indicates the mounting group. For preparing the panel, use the specific product drawing including the required hole, tolerance, mounting, and allowable material thickness. Also check the outer dimensions of the housing to avoid crossing with labels or neighboring controllers.

Do not assess visibility only by the size of the hole. Verify the operator's position, viewing angle, and ambient lighting. If multiple locations require an alert, a separate signalling beacon; panel signal and spatial signal solves different means of monitoring.

Replacement of the original indicator light in the existing panel

  1. Identify the original lineup: record the whole code and light block marking. The photo of the forehead is not enough.
  2. Compare mechanics: hole, panel thickness, mounting method, front contour and depth behind panel.
  3. Compare the electric part: power range, AC / DC, connection and collection according to documentation.
  4. Verify function and environment: colour, meaning of condition, conditions of coverage and temperature.
  5. Confirm delivery range: the complete indicator light and separate spare part are not the same.

Exchange 30mm execution for 22mm indicator is not an automatic replacement. A smaller element may not properly cover the hole, mount itself, or maintain the required panel properties. Any reduction or construction modification must be considered as part of the assembly; it cannot be assumed without documentation.

What is the supply range AC / DC in practice

The range, for example 12–30 V AC/DC for the above H050XB, specifies the allowed voltage under the manufacturer's conditions. It does not mean use on 230 V or unlimited tolerance for overvoltage. If the signal light is controlled by PLC, it is necessary to also verify the type and load capacity of the output.

Named insulation voltage and operating voltage have different meanings. A higher insulation parameter value does not indicate connecting to a higher operating voltage. Always use the voltage data relevant to the specific light element in operation.

How to write the applicable entry

Instead of specifying 'white large switch', for example: the required mounting dimension 30 mm, color, actual voltage, AC/DC type in the circuit, panel thickness, available depth, and environmental conditions. Only then can you evaluate the specific order code and its suitability.

Frequently asked questions

Does 30 mm automatically mean a more durable design than 22 mm?

No. Size, cover, material and electrical parameters are separate properties. Compare technical sheets.

Can the off signal confirm safe disconnection of the device?

No. The indicator light can be defective or without the input. Verification of a safe condition must not be based only on a light indication.

General principles can be found in signs guidesFor. selection of the refund Prepare precise marking and dimensional supporting documents. The installation must be performed by a competent person according to the documentation of the equipment and product.