Phone +420 774 723 123 Cart · 0 · empty

Signalling beacons

Selection of assembly, light and acoustic signals, power and control.

Subcategories

Filters
Found 529 products
OUR TIP

IT070G240Z, EMAS, optical LED horn, VEGETABLE, Ø 70mm, 48- 240V AC / DC, 130dB

Cat. no.: IT070G240Z

IT070G240Z EMAS - LED signalling beacon with acoustic signalling, green, 48-240 V AC / DC, 70 mm, IP65. Technical specifications, use, installation and selection of the correct variant.

On request
46,26 €
excl. VAT · 55,98 € incl. VAT
OUR TIP

IK71F220XM03E-RF, EMAS, red LED signal tower / beacon 70 mm, flashing, 220 V AC, IP65

Cat. no.: IK71F220XM03E-RF

IK71F220XM03E-RF EMAS - red LED signal tower / beacon 70 mm; red; 220 V AC; IP65. Precise technical specifications, use and selection of variants.

On request
46,57 €
excl. VAT · 56,35 € incl. VAT
OUR TIP

IK71F220XM03E-GF, EMAS, green LED signal tower / beacon 70 mm, flashing, 220 V AC, IP65

Cat. no.: IK71F220XM03E-GF

IK71F220XM03E-GF EMAS - green LED signal tower / beacon 70 mm; color green; 220 V AC; IP65. Precision technical specifications, use and selection of variants.

On request
46,57 €
excl. VAT · 56,35 € incl. VAT
OUR TIP

IK71F220XM03E-YF, EMAS, yellow LED signal tower / beacon 70 mm, flashing, 220 V AC, IP65

Cat. no.: IK71F220XM03E-YF

IK71F220XM03E-YF EMAS - yellow LED signal tower / beacon 70 mm; colour yellow; 220 V AC; IP65. Precise technical specifications, use and selection of variants.

On request
46,57 €
excl. VAT · 56,35 € incl. VAT
OUR TIP

IK71F220XM03E-WF, EMAS, white LED signal tower / beacon 70 mm, flashing, 220 V AC, IP65

Cat. no.: IK71F220XM03E-WF

IK71F220XM03E-WF EMAS - white LED signal tower / beacon 70 mm; white; 220 V AC; IP65. Precise technical specifications, use and selection of variants.

On request
46,57 €
excl. VAT · 56,35 € incl. VAT
OUR TIP

IK71F220XM03E-BLF, EMAS, blue LED signal tower / beacon 70 mm, flashing, 220 V AC, IP65

Cat. no.: IK71F220XM03E-BLF

IK71F220XM03E-BLF EMAS - blue LED signal tower / Beacon 70 mm; colours blue; 220 V AC; IP65. Precise technical specifications, use and selection of variants.

On request
46,57 €
excl. VAT · 56,35 € incl. VAT
OUR TIP

IF6P024WM05, EMAS, five- colour five-colour LED signalling beacon 65 mm, colours red + green + yellow + blue + white, permanent lighting, 24 V DC, IP65, PLC, with horn automatically 90-105 dB

Cat. no.: IF6P024WM05

IF6P024WM05 EMAS - five- colour five- colour LED signalling beacon 65 mm; colors red + green + yellow + blue + white; 24 V DC; IP65; horn automatically 90-105 dB; PLC. Precision technical…

On request
46,71 €
excl. VAT · 56,52 € incl. VAT
OUR TIP

TE-IK52L220ZM03-RG, EMAS, two-colour LED signal tower / beacon 50 mm, color red + green, permanent light, 220 V AC, IP40, with horn 90 dB, with mounting foot TECHNOLINE

Cat. no.: TE-IK52L220ZM03-RG

TE- IK52L220ZM03-RG EMAS - two-colour LED signal tower / beacon 50 mm; red + green colors; 220 V AC; IP40; horn 90 dB; TECHNOLINE mounting foot.

On request
47,06 €
excl. VAT · 56,95 € incl. VAT
OUR TIP

TE- IK52F024ZM03-RG, EMAS, two-colour LED signal tower / beacon 50 mm, color red + green, flashing, 24 V AC / DC, IP40, with horn 90 dB, with mounting foot TECHNOLINE

Cat. no.: TE-IK52F024ZM03-RG

TE- IK52F024ZM03-RG EMAS - two-colour LED signal tower / beacon 50 mm; red + green; 24 V AC / DC; IP40; horn 90 dB; installation foot TECHNOLINE. Precision technical specifications, use and selection…

On request
47,06 €
excl. VAT · 56,95 € incl. VAT
OUR TIP

TE-IF06P024WM05, EMAS, five-colour LED signal lamp 65 mm, colours red + green + yellow + blue + white, long-lasting, 24 V DC; IP65, PLC, with automatic hooter 90–105 dB, with TECHNOLINE mounting pin

Cat. no.: TE-IF06P024WM05

TE-IF06P024WM05 EMAS – five-colour LED signal lamp 65 mm; colours red + green + yellow + blue + white; 24 V DC; IP65; automatic hooter 90–105 dB; PLC; TECHNOLINE mounting pin. Precise technical…

On request
47,44 €
excl. VAT · 57,40 € incl. VAT
OUR TIP

TE- IK72L220XM03-RG, EMAS, two-colour LED signal tower / beacon 70 mm, color red + green, permanent light, 220 V AC, IP40, with mounting foot TECHNOLINE

Cat. no.: TE-IK72L220XM03-RG

TE- IK72L220XM03-RG EMAS - two-colour LED signal tower / beacon 70 mm; colours red + green; 220 V AC; IP40; mounting foot TECHNOLINE. Precision technical specifications, use and selection of variants.

On request
47,84 €
excl. VAT · 57,89 € incl. VAT
OUR TIP

TE- IK52F220ZM03-RG, EMAS, two-colour LED signal tower / beacon 50 mm, color red + green, flashing, 220 V AC, IP40, with horn 90 dB, with mounting foot TECHNOLINE

Cat. no.: TE-IK52F220ZM03-RG

TE- IK52F220ZM03-RG EMAS - two-colour LED signal tower / beacon 50 mm; colours red + green; 220 V AC; IP40; horn 90 dB; installation foot TECHNOLINE.

On request
48,58 €
excl. VAT · 58,78 € incl. VAT
OUR TIP

IK52L024ZM03-RG, EMAS, two-colour LED signal tower / beacon 50 mm, color red + green, permanent light, 24 V AC / DC, IP40, with horn 90 dB

Cat. no.: IK52L024ZM03-RG

IK52L024ZM03-RG EMAS - two-colour LED signal tower / beacon 50 mm; colors red + green; 24 V AC / DC; IP40; horn 90 dB.

On request
49,23 €
excl. VAT · 59,57 € incl. VAT
OUR TIP

IK52L220ZM03-RG, EMAS, two-colour LED signal tower / beacon 50 mm, color red + green, permanent light, 220 V AC, IP40, with horn 90 dB

Cat. no.: IK52L220ZM03-RG

IK52L220ZM03-RG EMAS - two- colour LED signal tower / beacon 50 mm; colours red + green; 220 V AC; IP40; horn 90 dB.

On request
50,38 €
excl. VAT · 60,96 € incl. VAT
OUR TIP

IK52F024ZM03-RGF, EMAS, two-colour LED signal tower / beacon 50 mm, color red + green, flashing, 24 V AC / DC, IP40, with horn 90 dB

Cat. no.: IK52F024ZM03-RGF

IK52F024ZM03-RGF EMAS - two-colour LED signal tower / beacon 50 mm; colors red + green; 24 V AC / DC; IP40; horn 90 dB.

On request
50,38 €
excl. VAT · 60,96 € incl. VAT
OUR TIP

TE-IK53L024XM03-RGY, EMAS, three-colour LED signal tower / beacon 50 mm, color red + green + yellow, permanent light, 24 V AC / DC, IP40, with mounting foot TECHNOLINE

Cat. no.: TE-IK53L024XM03-RGY

TE- IK53L024XM03-RGY EMAS - three-colour LED signal tower / beacon 50 mm; colours red + green + yellow; 24 V AC / DC; IP40; mounting foot TECHNOLINE. Precision technical specifications, use and…

On request
50,99 €
excl. VAT · 61,70 € incl. VAT
OUR TIP

IK72L220XM03-RG, EMAS, two-colour LED signal tower / beacon 70 mm, color red + green, permanent light, 220 V AC, IP40

Cat. no.: IK72L220XM03-RG

IK72L220XM03-RG EMAS - two-colour LED signal tower / beacon 70 mm; colours red + green; 220 V AC; IP40. Precision technical specifications, use and selection of variants.

On request
51,20 €
excl. VAT · 61,95 € incl. VAT
OUR TIP

TE-IK53L220XM03-RGY, EMAS, three-colour LED signal tower / beacon 50 mm, color red + green + yellow, permanent light, 220 V AC, IP40, with mounting foot TECHNOLINE

Cat. no.: TE-IK53L220XM03-RGY

TE- IK53L220XM03-RGY EMAS - three-colour LED signal tower / beacon 50 mm; colours red + green + yellow; 220 V AC; IP40; mounting foot TECHNOLINE. Precision technical specifications, use and selection…

On request
52,06 €
excl. VAT · 62,99 € incl. VAT
OUR TIP

TE-IK53F024XM03-RGY, EMAS, three-colour LED signal tower / beacon 50 mm, colours red + green + yellow, flashing, 24 V AC / DC, IP40, with installation foot TECHNOLINE

Cat. no.: TE-IK53F024XM03-RGY

TE- IK53F024XM03-RGY EMAS - three-colour LED signal tower / beacon 50 mm; colours red + green + yellow; 24 V AC / DC; IP40; mounting foot TECHNOLINE. Precision technical specifications, use and…

On request
52,06 €
excl. VAT · 62,99 € incl. VAT
OUR TIP

IF3N024OS30-1, EMAS, five- colour LED signalling beacon 50 mm, color red + green + yellow + blue + white, permanent light, 24 V DC, IP67, NPN PLC, cable 1 m

Cat. no.: IF3N024OS30-1

IF3N024OS30-1 EMAS - five- colour LED signalling beacon 50 mm; colors red + green + yellow + blue + white; 24 V DC; IP67; NPN PLC. Precise technical specifications, use and selection of variants.

On request
52,75 €
excl. VAT · 63,83 € incl. VAT
OUR TIP

TE- IK72L220ZM03-RG, EMAS, two-colour LED signal tower / beacon 70 mm, color red + green, permanent light, 220 V AC, IP40, with horn 90 dB, with mounting foot TECHNOLINE

Cat. no.: TE-IK72L220ZM03-RG

TE- IK72L220ZM03-RG EMAS - two-colour LED signal tower / beacon 70 mm; colours red + green; 220 V AC; IP40; horn 90 dB; mounting foot TECHNOLINE. Precision technical specifications, use and selection…

On request
53,29 €
excl. VAT · 64,48 € incl. VAT
OUR TIP

TE-IF03N024OS30-1, EMAS, five- colour LED signalling beacon 50 mm, colors red + green + yellow + blue + white, permanent light, 24 V DC, IP67, NPN PLC, cable 1 m, with mounting foot TECHNOLINE

Cat. no.: TE-IF03N024OS30-1

TE-IF03N024OS30-1 EMAS – five-colour LED signal lamp 50 mm; colours red + green + yellow + blue + white; 24 V DC; IP67; NPN PLC; TECHNOLINE mounting pin. Precise technical parameters, usage and…

On request
53,42 €
excl. VAT · 64,64 € incl. VAT
OUR TIP

TE- IK53F220XM03-RGY, EMAS, three-colour LED signal tower / beacon 50 mm, red + green + yellow, flashing, 220 V AC, IP40, with TECHNOLINE mounting foot

Cat. no.: TE-IK53F220XM03-RGY

TE- IK53F220XM03-RGY EMAS - three-colour LED signal tower / beacon 50 mm; colours red + green + yellow; 220 V AC; IP40; installation foot TECHNOLINE. Precision technical specifications, use and…

On request
53,53 €
excl. VAT · 64,77 € incl. VAT

Prices include the recycling fee.

Signalling beacons

The signal light converts the state of the device into information that the operator recognizes without reading the display. When selecting, start with the question of what a person should do after the light comes on or the signal sounds. Another request may have local warnings for material replenishment and other signal lights visible from the access street. The color, light mode, location, and any sound should form a clear whole.

The category includes various constructions and parts of assemblies. It is not possible to deduce common voltage, protection, dimensions or method of control from its name. Panel indication and LED strips are detailed in the guide Signal lamps and LED strips; here the main topic is the choice and integration of beacon into the machine.

Complete beacon, segment or replacement light source?

A complete version includes the manufacturer's specified assembly. A standalone segment represents only its part. In a modular system, distinguish between the base, light levels, light sources, ends and possible acoustic module. EMAS Catalogue The series of IK distinguishes clearly between individual parts and complete assemblies. However, always check the delivery scope according to the specific item.

Before ordering, assemble a parts list: what is already on the machine, what is changing and what will be needed to add. A coloured transparent segment does not necessarily contain an LED source; the mounting tube does not necessarily contain a pin or connection part. Products of the same external diameter may have different locks, contacts or seals. When replacing, therefore, compare the manufacturer, series and full code of the original part.

A separate category is used for replacing the source LED bulbs up to 50mm and 70mm beacons Emas. Continue with the holders and adapters through Beacons accessories. Add space for wiring and for later disassembly, not only the height of the light part.

What signal should the operator recognize?

  • Continuous light allows long-term display of the state. Its meaning is determined in the control description of the machine.
  • The Flashing alternates between the light being on and off. It may indicate the change, but it must be clear whether it is produced by a beacon or by a control system.
  • Flash mode uses short pulses; it is not automatically identical to normal flickering. It is determined by the actual course and supported settings.
  • Rotational effect may occur through sequential illumination of LEDs. The designation itself does not confirm the presence of a motor or mechanically rotating optics.
  • An acoustic signal draws attention when the operator is not looking towards the equipment. The method of confirmation and silencing must correspond to the process.

Multiple colours in one body are not the same as several separate lighting modules. Determine whether a single selected colour, multiple separated areas, or a combination intended by the electronics is displayed. This is addressed by the category Beacons more colorful and multifunctional EMAS. The number of colours alone does not indicate the number of independent inputs.

Power supply and control should be addressed separately

The power supply rating indicates the electrical energy the product requires. The control interface indicates how you select the colour, lighting mode or sound. Some devices are activated by supplying power, others have additional control wires. The designation 24 V DC does not indicate whether you need a PNP output, NPN output or a no-voltage contact. The AC/DC power supply rating also does not mean any voltage on all terminals.

  1. Check the rated voltage and allowable range of each connected part. Do not confuse the output voltage of the source with the voltage of the control input.
  2. According to the diagram, determine the common conductor, polarity and function of individual wires. Do not transfer wire colours between different manufacturers.
  3. Sum the currents of functions that may be activated simultaneously. Also verify the maximum load of each output and the entire group of PLC outputs.
  4. Assess the switching current and voltage drop on the wiring. If an isolating unit is required, select it according to the actual load and frequency of switching.
  5. Verify the behaviour during PLC start-up, power loss and signal overlap. Unintended signal combinations must have a pre-defined solution.

When servicing, first disconnect the power supply and verify the circuit status. A trial operation of an unknown component on a randomly selected voltage does not replace its identification. If the documentation is insufficient, supplement with a diagram or label information before connecting.

Visibility of light and audibility of sound

The size of the light-emitting area is just one part of the selection. Check the operator's view during normal operation, shielding by the housing, backlighting and distance. Optical data in candelas apply to the direction of radiation; lumens describe the total luminous flux. The power consumption alone or the number of LEDs does not prove the readability of a specific status.

When comparing sound, compare the sound pressure level at the same distance and with the same frequency weighting. A dB rating without these conditions is insufficient. Selection belongs to the category Horns. The acoustic rating does not in any way express the visibility of the light part.

A practical takeover may take the form of a short test run: operator stations, material replenishment location and access corridors. At each location, activate individual states and record whether the person correctly recognises them. Repeat the test with closed covers, normal lighting and during real operation of adjacent equipment.

Model example: three states and confirmation of warning

The model workstation should display readiness, material request and operational fault. The designer first creates a table of states and their priorities. When a material request and a fault occur simultaneously, the fault takes precedence; after its removal, the other conditions are re-evaluated. Specific colours and rhythm are determined according to the rules of the machine.

Let's assume three independent light branches of 0.04 A each and an audio branch of 0.10 A. For a permissible current flow of all branches, it is 3 × 0.04 + 0.10 = 0.22 A, which is approximately 5.28 W. This is just a calculation based on hypothetical input values, not the parameters of the supplied light. The switching current, reserve power, and cable load must be considered separately.

If the selected device allows separate control of sound, the operator's confirmation may silence the acoustic branch and leave the display of the cause. The confirmation must not by mistake erase the fault state itself. Verify this procedure also during repetition of the event.

Common questions and errors in selection

Does a green light mean that it is allowed to enter the machine?

The light itself does not indicate a safe state. A common status signal does not automatically represent a safety function and does not replace protective equipment or risk assessment. A LED failure, cable, or control can change the display.

Just pick the same cover as the original beacon?

Check also the mounting conditions, sealing and cable entry. Housing alone does not provide information about resistance to chemicals, long-term sunlight or vibrations. Parameters of one assembly cannot be transferred to all products in the category.

Can I assign a different effect to each warning?

Only within the scope of functions of a specific product and with a clear signalisation concept. Start with a small number of unambiguous states. Before handing over the machine, verify their recognition and store the meanings and wiring in the documentation.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.