IKAM02, TECHNOLINE, mounting foot for IK5/IK7, 20 mm
IKAM02 TECHNOLINE - mounting foot; compatibility / determination: IK5, IK7, length 20 mm. Installation accessories for industrial signalling.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Holders, feet and adapters according to the beacon series and method of assembly.
IKAM02 TECHNOLINE - mounting foot; compatibility / determination: IK5, IK7, length 20 mm. Installation accessories for industrial signalling.
IKAMI03 TECHNOLINE - installation foot for indicators; compatibility / determination: IF03, length 92 mm. Installation accessories for industrial signalling.
IKAD50 TECHNOLINE - adjustable holder; compatibility / determination: IK5, IK7. Assembly accessories for industrial signalling.
TEIKAM10 TECHNOLINE - mounting foot; compatibility / determination: IF5T, IF05, length 75 mm. Installation accessories for industrial signalling.
IKAM03 TECHNOLINE - mounting foot; Compatibility / determination: IK5, length 100 mm. Installation accessories for industrial signalling.
IKAD51 TECHNOLINE - adjustable holder; compatibility / determination: IK5, IK7. Installation accessories for industrial signalling.
TL-CZ-1 TECHNOLINE - wall bracket; compatibility / determination: APT, EMAS. Assembly accessories for industrial signalling.
IKAM04 TECHNOLINE - mounting foot; compatibility / determination: IK5, IK7, length 200 mm. Installation accessories for industrial signalling.
IKAD20 EMAS - adjustable holder; compatibility / determination: IK5, IK7. Assembly accessories for industrial signalling.
IKAD40 TECHNOLINE - mounting brackets; compatibility / determination: IK5, IK7. Assembly accessories for industrial signalling.
IKAM05 TECHNOLINE - mounting foot; compatibility / determination: IK5, IK7, length 500 mm. Installation accessories for industrial signalling.
KON-IT120 TECHNOLINE - wall console; compatibility / determination: IT120. Assembly accessories for industrial signalling.
UD-IF03 TECHNOLINE - angle bracket; compatibility / destination: IF03. Installation accessories for industrial signalling.
IKAD41 TECHNOLINE - mounting brackets; compatibility / determination: IK5, IK7. Assembly accessories for industrial signalling.
IKAM01 TECHNOLINE - mounting foot; compatibility / determination: APT, IK7, length 85 mm. Installation accessories for industrial signalling.
Prices include the recycling fee.
The holder or mounting pin determines where the light will see, where the cable will lead, and how the assembly will mechanically support it. The selection of components starts with a specific light and its mounting drawing. The same diameter of the light part or similar part code does not guarantee mutual compatibility.
The catalog includes parts TECHNOLINE and EMAS for various constructions. A single pin, console, or adapter does not represent a complete electrically functional light. An overview of the required parts is provided by the guide. Signalling beacons.
Examine the assembly from the machine to the light part: mounting surface, base or console, optional pipe, adapter, and light. For each connection, compare the pitch, bend, diameter, length of insertion, and securing. If any connection is not marked in the drawing, it cannot be confirmed by the photo.
For example, EMAS indicates: IKAD20 as a settable wall holder without a pipe. This example shows why it is necessary to read the range of delivery: the holder itself does not have to contain all elements of the assembly shown in the illustration. For the same or similar marking in the offer, always verify with the manufacturer.
The mechanical adapter does not change the supply voltage or control principle of the lamp. After installation, it must still comply with the supply, polarity, common wire, and load capacity of the outputs. A prepared cable passage does not automatically mean the presence of electrical contacts or a connector.
Verify the diameter of the passage, the space for bending, and the relief of the pull. The cable must not be bent by the edge or tightened by the holder. The covering of the resulting assembly depends on the passage, closure, and tightening; a declaration of one part cannot be transferred to the whole without justification. For compact heads, compare the construction in the category Multi-function indicators.
Assume an educational lateral force of 2 N acting on the top of the fixed assembly. At an arm length of 0.10 m, it creates a moment of 0.20 N·m, at an arm length of 0.50 m, 1.00 N·m. Doubling the height thus doubles the moment. This is not a statement about the allowable load of any supplied holder; vibrations and dynamic effects are not addressed by this simple model.
The practical procedure is first to determine the required view, then compare possible mounting points, and finally verify the load-bearing capacity of the chosen combination. For an optical-acoustic assembly, also check that the holder or surrounding cover does not obstruct the light part or audio output.
Only if the combination is confirmed by dimensions and by the manufacturer's designation. Especially compare the interface of compact heads and modular columns, for example in the category Beacons more colorful and multifunctional EMAS.
It can remove the cover, but also expose the beacon of impact or increase trembling. Verify the correct position from where the condition is to be recognized and during normal operation of the operator.
The accessories themselves do not create such a function. The fixing ensures mechanical installation; the safety characteristics of the whole installation shall be based on its documented design.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.