IKML024B, EMAS, LED light bulb white
IKML024B EMAS - LED light source for signalling beacon, white, 24 V AC / DC. Technical specifications, use, installation and selection of the correct variant.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Replacement LED power supplies, voltage, color and permanent or interrupted light.
IKML024B EMAS - LED light source for signalling beacon, white, 24 V AC / DC. Technical specifications, use, installation and selection of the correct variant.
IKML024K EMAS - LED light source for signalling beacon, red, 24 V AC / DC. Technical specifications, use, installation and selection of the correct variant.
IKML024M EMAS - LED light source for signalling beacon, blue, 24 V AC / DC. Technical specifications, use, installation and selection of the correct variant.
IKML024S EMAS - LED light source for signalling beacon, yellow, 24 V AC / DC. Technical specifications, use, installation and selection of the correct variant.
IKML024Y EMAS - LED light source for signalling beacon, green, 24 V AC / DC. Technical specifications, use, installation and selection of the correct variant.
IKML220B EMAS - LED light source for signalling beacon, white, 220 V AC. Technical specifications, use, installation and selection of the correct variant.
IKML220K EMAS - LED light source for signalling beacon, red, 220 V AC. Technical specifications, use, assembly and selection of the correct variant.
IKML220M EMAS - LED light source for signalling beacon, blue, 220 V AC. Technical specifications, use, installation and selection of the correct variant.
IKMF024B EMAS - LED light source for signalling beacon, white, 24 V AC / DC. Technical specifications, use, installation and selection of the correct variant.
IKMF024K EMAS - LED light source for signalling beacon, red, 24 V AC / DC. Technical specifications, use, installation and selection of the correct variant.
IKMF024M EMAS - LED light source for signalling beacon, blue, 24 V AC / DC. Technical specifications, use, installation and selection of the correct variant.
IKMF024S EMAS - LED light source for signalling beacon, yellow, 24 V AC / DC. Technical specifications, use, installation and selection of the correct variant.
IKMF024Y EMAS - LED light source for signalling beacon, green, 24 V AC / DC. Technical specifications, use, assembly and selection of the correct variant.
IKMF220B EMAS - LED light source for signalling beacon, white, 220 V AC. Technical specifications, use, assembly and selection of the correct variant.
IKMF220K EMAS - LED light source for signalling beacon, red, 220 V AC. Technical specifications, use, assembly and selection of the correct variant.
IKMF220M EMAS - LED light source for signalling beacon, blue, 220 V AC. Technical specifications, use, installation and selection of the correct variant.
IKMF220S EMAS - LED light source for signalling beacon, yellow, 220 V AC. Technical specifications, use, installation and selection of the correct variant.
IKMF220Y EMAS - LED light source for signalling beacon, green, 220 V AC. Technical specifications, use, installation and selection of the correct variant.
IKML220S EMAS - LED light source for signalling beacon, yellow, 220 V AC. Technical specifications, use, installation and selection of the correct variant.
IKML220Y EMAS - LED light source for signalling beacon, green, 220 V AC. Technical specifications, use, installation and selection of the correct variant.
Prices include the recycling fee.
Replacing the light source allows servicing a compatible light without replacing the entire signalling assembly. The catalog LED bulb designation here means LED light sources for the specific implementation of the light, not classic filament bulbs. The 50 mm and 70 mm dimensions in the category name describe the size of the lights; they do not guarantee the suitability of the source for each product of this size.
In the list, for example, the families IKML and IKMFThe replacement source is not a complete optical segment with cover or finished beacon. The difference between the components explains the guide Signalling beacons.
The LED source contains electronics. Therefore, when replacing a different construction, verify not only the normal consumption, but also the state during the output off and power on. Weak flashing does not necessarily mean a faulty source: during diagnostics, check the residual output current or test pulses of the control module. Their acceptability must match the specific circuit.
Do not use two blinking sources automatically at the same time. If an internally blinking plug is cycling simultaneously with a PLC, the resulting rhythm may be unreadable. For a replacement plug, do not expect a change in the mechanical cover of the entire assembly. This depends on proper closure, tightening, and cable input of the light.
Let's assume a light that has been continuously glowing on its fault level when the PLC output is active. The technician inserts a voltage-appropriate, but internally blinking source. Electrical switching works, but the meaning of the signal has changed. The correct procedure is to compare the original order code and the desired behavior, then verify all states during the operational test, including shutdown. This is a model situation, not a description of a specific complaint.
After replacement, compare readability both with the closed coloured cover and from the normal operator's position. Identical colour in the name or lower power consumption does not prove the same visibility. The mounting position can be resolved via Beacons accessories, always with verification of the compatibility of the entire assembly.
It is determined by the allowed range of the specific source. Do not determine compatibility only by the filter or numerical part of the order code. Before connection, compare the label and the corresponding technical sheet.
The new source restores the indication; it does not create a safety function. The extinguishing of light cannot be interpreted as confirmation of a safe state without further context.
No, without documented electrical and mechanical compatibility. The related area is explained by Signal lamps and LED strips; constructions intended for other holders or connectors are not an automatic replacement.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.