PUC6x4-15BL, TECHNOLINE, coiled polyurethane pneumatic tube, 6×4mm, working length 15m, blue
PUC6x4-15BL, TECHNOLINE, coiled PU tube 6×4mm, blue, working length 15m and free ends. Working pressure 10bar, temperature −20 to +60°C.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Selecting the material, diameter and route of the tube
PUC6x4-15BL, TECHNOLINE, coiled PU tube 6×4mm, blue, working length 15m and free ends. Working pressure 10bar, temperature −20 to +60°C.
PUC8x5.5-10BL, TECHNOLINE, coiled PU tube 8×5.5mm, blue, working length 10m and free ends. Working pressure 10bar, temperature −20 to +60°C.
PUC 8x5.5 6M CL, TECHNOLINE, coiled PU tube 8×5.5mm, clear, working length 6m and free ends. Working pressure 10bar, temperature −20 to +60°C.
PUC8x5.5-15BL, TECHNOLINE, coiled PU tube 8×5.5mm, blue, working length 15m and free ends. Working pressure 10bar, temperature −20 to +60°C.
TC-02, TECHNOLINE, pneumatic tube pliers up to Ø16mm. A square cut makes it easier to seal the tube in a push-in fitting.
PUC10x6.5-10BL, TECHNOLINE, coiled PU tube 10×6.5mm, blue, working length 10m and free ends. Working pressure 10bar, temperature −20 to +60°C.
PUC8x5.5-20BL, TECHNOLINE, coiled PU tube 8×5.5mm, blue, working length 20m and free ends. Working pressure 10bar, temperature −20 to +60°C.
PUC 10x6.5 15M BL, TECHNOLINE, coiled PU tube 10×6.5mm, blue, working length 15m and free ends. Working pressure 10bar, temperature −20 to +60°C.
PUC12x8-10BL, TECHNOLINE, coiled PU tube 12×8mm, blue, working length 10m and free ends. Working pressure 10bar, temperature −20 to +60°C.
PUC12x8-15BL, TECHNOLINE, coiled PU tube 12×8mm, blue, working length 15m and free ends. Working pressure 10bar, temperature −20 to +60°C.
PUC12x8-20BL, TECHNOLINE, coiled PU tube 12×8mm, blue, working length 20m and free ends. Working pressure 10bar, temperature −20 to +60°C.
PUC10x6.5-20BL, TECHNOLINE, coiled PU tube 10×6.5mm, blue, working length 20m and free ends. Working pressure 10bar, temperature −20 to +60°C.
TPA4X2B, TECHNOLINE, polyamide tube 4×2mm, black. For Ø4mm push-in fittings; material PA.
TPU6X4BL, TECHNOLINE, polyurethane pneumatic tube 6×4mm, blue. Working pressure 10bar, burst pressure 30bar, −20 to +60°C.
PTFE 4x2.5, TECHNOLINE, smooth PTFE Teflon tube Ø4×2.5mm without braid, working pressure 18.7bar, temperature range −73 to +260°C.
PUC8x5.5-4BL, TECHNOLINE, coiled PU tube 8×5.5mm, blue, working length 4m and free ends. Working pressure 10bar, temperature −20 to +60°C.
PUC6x4-10BL, TECHNOLINE, coiled PU tube 6×4mm, blue, working length 10m and free ends. Working pressure 10bar, temperature −20 to +60°C.
PUC6x4-20BL, TECHNOLINE, coiled PU tube 6×4mm, blue, working length 20m and free ends. Working pressure 10bar, temperature −20 to +60°C.
TU0425B-20 – SMC polyurethane tube, diameter 4.0/2.5mm, length 20m, colour black. Intended for pneumatic compressed air distribution. Max. operating pressure 0.8 MPa, temperature –20 to +60 °C.
TU0425BU-20, SMC, polyurethane tube, OD 4 mm / ID 2.5 mm, roll 20 m, blue. The tube carries compressed air or another permitted medium between elements of the pneumatic system. The design must…
TU0425G-20, SMC, polyurethane tube, OD 4 mm / ID 2.5 mm, roll 20 m, green. The tube carries compressed air or another permitted medium between elements of the pneumatic system. The design must…
TU0425W-20, SMC, polyurethane tube, OD 4 mm / ID 2.5 mm, roll 20 m, white. The tube carries compressed air or another permitted medium between elements of the pneumatic system. The design must…
TU0425Y-20, SMC, polyurethane tube, OD 4 mm / ID 2.5 mm, roll 20 m, yellow. The tube carries compressed air or another permitted medium between elements of the pneumatic system. The design must…
TU0425R-20, SMC, polyurethane tube, OD 4 mm / ID 2.5 mm, roll 20 m, red. The tube carries compressed air or another permitted medium between elements of the pneumatic system. The design must respect…
TU0425C-20, SMC, polyurethane tube, OD 4 mm / ID 2.5 mm, roll 20 m, clear. The tube carries compressed air or another permitted medium between elements of the pneumatic system. The design must…
Prices include the recycling fee.
Choose the tube as part of the whole route between the air source and the point of consumption. The medium, temperature, pressure, length, space and connection method are decisive. When replacing an old line, first copy the designation and measure both diameters. Neither colour nor similar appearance is a sufficient basis for an order.
The listing includes Pneuflex and SMC tubes, straight and coiled versions and cutting tools. The material branches include PU, PTFE and FEP; polyamide is also represented. Selection therefore starts with the operating specification, not the assumption that all items have the same properties.
For a flexible line, assess Polyurethane PU tubes. Pneuflex for ester-based PU emphasises flexibility and abrasion resistance; for polyamide describes options for higher pressures and temperatures than PU. This is a characteristic of these families, not common limit values for all offered sizes.
If the specification includes a chemical medium or elevated temperature, compare Teflon tubes a Fluoropolymer FEP tubes. In the enquiry, state the specific substance, concentration, temperature and contact time. State separately whether the substance flows inside or is used for external cleaning. Only with these data can documentation of the suitability of the whole assembly be requested.
Compare the outer diameter with the requirements of the fitting, the inner diameter with the need for media flow. SMC TU/TIUB table states both dimensions separately and distinguishes metric and inch versions. In addition to the dimension, verify the prescribed material and tolerance; similar numbers in the catalogue do not by themselves prove interchangeability.
For the design, draw the route and mark every fitting, sheet-metal pass-through and change of direction. For each point, decide whether it must remain accessible for service. The drawing allows two routing variants to be compared before purchase and reveals unnecessary loops. For a moving workplace, consider separately Coiled polyurethane PU tubes according to the working reach actually needed.
Let us consider, purely for tutorial purposes, two four-metre tubes with an inner diameter of 4 and 6 mm. The volume of the cylindrical space V = π × d² × L / 4 is approximately 50.3 and 113.1 ml. The second variant has 2.25 times larger internal volume. The calculation uses chosen dimensions, not the parameters of a specific product.
The result shows how much space the route itself contains. It does not determine the flow rate, pressure loss or response time. To assess them, add the actual working pressure, consumption and all local resistances. When changing the length, also recalculate the volume; do not compare a new line only by diameter.
According to the SMC mounting instructions disconnect the supply and release the residual pressure. Check for an undamaged square cut, insertion into the specified fitting and routing without tension or twisting. For preparing the ends, use Cutting pliers, knives.
In case of problems, record whether they occur permanently, during consumption, after warming up, or only in a certain position of the machine. Always check one branch at a time and record the changes made. This separates observation from assumption and avoids repeated tube replacement without finding the cause.
Use colour for your own clear marking. Determine the replacement by the full code, dimensions and documented conditions of use.
The dimensions alone determine the geometric volume. Consumption also requires a description of the working cycle and pressure states; the stated model does not calculate it.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.