Phone +420 774 723 123 Cart · 0 · empty

Teflon tubes

PTFE tubes: medium, dimensions and connection

Filters
Found 5 products
IN STOCK

PTFE 6x4, TECHNOLINE, smooth PTFE Teflon tube without braid, Ø6×4mm, wall 1mm

Cat. no.: PTFE 6x4

PTFE 6x4, TECHNOLINE, smooth PTFE Teflon tube Ø6×4mm without braid, working pressure 16bar, temperature range −73 to +260°C.

In stock 5 or more pcs
2,97 €
excl. VAT · 3,60 € incl. VAT
IN STOCK

PTFE 8x6, TECHNOLINE, smooth PTFE Teflon tube without braid, Ø8×6mm, wall 1mm

Cat. no.: PTFE 8x6

PTFE 8x6, TECHNOLINE, smooth PTFE Teflon tube Ø8×6mm without braid, working pressure 11bar, temperature range −73 to +260°C.

In stock 5 or more pcs
3,33 €
excl. VAT · 4,03 € incl. VAT
IN STOCK

PTFE 12x8, TECHNOLINE, smooth PTFE Teflon tube without braid, Ø12×8mm, wall 2mm

Cat. no.: PTFE 12x8

PTFE 12x8, TECHNOLINE, smooth PTFE Teflon tube Ø12×8mm without braid, working pressure 15.4bar, temperature range −73 to +260°C.

In stock 5 or more pcs
5,67 €
excl. VAT · 6,87 € incl. VAT

Prices include the recycling fee.

Teflon tubes

This category contains white Pneuflex tubes marked PTFE. When selecting, the exact material designation and dimension are essential, because the general category name alone is not a technical specification. Start with what is to flow through the line, under what conditions and into what connection the tube is to be inserted.

Pneuflex describes PTFE as a material with pronounced chemical and thermal resistance and low friction. That is a reason to include it among the options considered. However, the specific working pressure, permitted medium and suitability of the whole assembly require documentation for the selected size and operation.

What the media specification must contain

In the technical specification, write the name of the substance, concentration, normal and maximum temperature and contact time. Distinguish continuous operation, short dosing and cleaning. If the medium changes during the process, describe the whole sequence including flushing. Submit exactly this record to the supplier for assessment, instead of a request for a universally resistant tube.

Mark the process cleanliness requirement separately. Write down which documents must accompany the delivery and whether you require batch traceability. If you use the line in the food industry, decide which documents the specific application requires; a general list of industrial uses is not such a document.

Assess dimension and connection together

Manufacturing detail PTFE 6x4 distinguishes the outer diameter of 6 mm from the inner 4 mm. State both in the order. Do not consider the same outer diameter with a different wall thickness as an identical replacement without verification; compare the requirements of the specific connection and the documented operating limits.

When designing the route, prepare a list of all wetted components, not just the tube. Have the material and conditions of use confirmed for each. Also determine where the joint should be accessible for inspection and how the line will be replaced. If you are comparing fluoropolymers, continue to the category Fluoropolymer FEP tubes; make the selection according to the specific datasheets.

Model calculation of route volume

Let us consider our own tutorial model: a straight tube 2.8 m long with an inner diameter of 4 mm. The geometric volume V = π × d² × L / 4 is approximately 35.2 ml. Three such volumes represent about 105.6 ml. The dimensions are an input of the model, not a declaration of the parameters of a specific product.

The calculation is only for orientation in the amount of liquid contained in the tube. Three volumes are not an instruction for effective flushing or a confirmation of removal of the previous substance. For an actual process, add other internal spaces and establish a separate validated cleaning procedure. The model thus helps prepare the specification but does not replace its validation.

Mounting and operating record

Prepare the mounting from the route drawing and the instructions for the specific connection. Write down the required length, permissible bends and the procedure for securing the ends. For cutting, compare Cutting pliers, knives with the material and diameter of the tube; verify the suitability of the tool in its documentation.

As our own check procedure, we recommend recording the appearance of the line, the position of the joints and the result of the prescribed test at handover. If behaviour changes later, add the medium used, temperature, length of operation and last cleaning. This set of data allows the supplier to assess the cause without random switching of materials.

FAQ

Does PTFE mean resistance to every chemical?

Do not derive such a universal guarantee from the designation. Request a statement on the specific substance, conditions and the whole assembly.

Can I take over the pressure from another tube of the same diameter?

Not without documentation of the given variant. To compare material options, use the overview Pneumatic tubes and then the sheet of the exact product.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.