Phone +420 774 723 123 Cart · 0 · empty

Fluoropolymer FEP tubes

FEP tubes: pressure, temperature and fixed installation

Filters
Found 1 products
OUR TIP

TH0604B-20, SMC, FEP fluoropolymer tube 6/4 mm, black, roll 20 m

Cat. no.: TH0604B-20

TH0604B-20 SMC – FEP fluoropolymer tube 6/4 mm, black, roll 20 m. The variant is intended for pneumatic distribution according to the stated dimensions and material.

On request
192,38 €
excl. VAT · 232,79 € incl. VAT

Prices include the recycling fee.

Fluoropolymer FEP tubes

FEP is the designation of a fluoropolymer material. In the current listing, this category is represented by TH0604B-20 from SMC. Therefore, base the selection on the TH series documentation and the full order code. The name of the material group alone does not determine the permitted operation or the form of connection.

What a specific series proves

SMC TH table on page 726 assigns model TH0604 an outer diameter of 6 mm and an inner diameter of 4 mm. The letter B designates the black opaque version, the suffix 20 a roll length of 20 m. The manufacturer states fixed use for the series and does not permit it in places where the tube moves.

Draw the parts of the equipment that change position during operation. Easy manual bending does not prove suitability for repeated movement; such a mode must be explicitly permitted by the documentation of the selected version.

Assess the pressure at the operating temperature

For TH0604 the manufacturer states maximum 1.5 MPa at 20 °C or less and 0.55 MPa at 100 °C. The usable limit of the assembly is determined by the lower permitted value of the tube or connection. The media table lists air, water and inert gas; do not assess another medium solely by the name FEP.

For your own specification, create an overview of operating states: cold start, normal operation, maximum temperature and cleaning. Assign pressure and medium to each. Assessing the whole table prevents a state that lasts briefly but is part of the regular working cycle from being overlooked during selection. Also state the measuring point and how the values were obtained, so that the specification can later be compared with reality.

If the machine documentation generally states a fluoropolymer, add the exact material designation. The compared Teflon tubes assess according to its own manufacturing sheet. Do not consider the same size or a similar colour as a basis for approving a replacement.

Model calculation of arc length

For our own tutorial model, let us choose a route with two straight sections of 120 mm each and one right-angle arc whose radius measured to the line axis is 50 mm. The arc length is π × 50 / 2 = approximately 78.5 mm. The whole geometric route therefore measures 120 + 78.5 + 120 = 318.5 mm.

This is design geometry with arbitrarily chosen inputs, not a prescribed radius or finished cutting length of a product. The calculation does not include insertion into fittings. Before cutting, compare the chosen bend with the documentation of the exact tube and add mounting lengths according to the connection drawing. When the supply position changes, recalculate the whole route.

Mounting and diagnostics of a rigid line

Add support points, access to joints and the prescribed test procedure to the mounting plan. Select a tool for preparing the ends in the category Cutting pliers, knives only after verifying its suitability for the given material. Document the handover with a photo of the actual route.

As our own diagnostic procedure, in case of problems we recommend comparing actual operation with the specified table of states. Record where the problem appeared and whether it was preceded by heating, cleaning or intervention in the line. Then check the relevant section according to the manufacturer's instructions; simply increasing the clamping force or randomly changing the material is not a documented solution to the cause.

FAQ

How to prepare an enquiry for a rigid line?

Attach the full code, a route sketch and a table of media, pressures and temperatures. Add the required quantity and packaging method.

Is it enough to know the maximum permitted pressure when selecting?

You need the value at the actual temperature, the specified medium and the connection conditions. An overview of other material branches can be found in the category Pneumatic tubes.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.