Phone +420 774 723 123 Cart · 0 · empty

Sensor Cables and Connectors

Connection cables with a M8 or M12 connector let you replace a sensor within a minute, without disconnecting the terminal block in the control cabinet. You will find straight and angled versions, female sockets for connecting to the sensor and male plugs for the opposite end, lengths from 2 to 10 metres and three to five wires depending on whether it is a switching sensor, analogue output or IO-Link communication. A PVC jacket is sufficient for fixed installation; for drag chains and moving machine parts choose PUR, which withstands repeated bending and oil. The range is complemented by distribution boxes for connecting several sensors to one input module, connectors for your own wiring and extension cables. If needed, contact us and we will be happy to help you choose the right type for your application.

Subcategories

Filters
Found 272 products
OUR TIP

DB080403-1-05N, LANBAO, sensor distribution box M8, 4 ports 3pin, PVC 5m, NPN

Cat. no.: DB080403-1-05N

Lanbao passive sensor distribution box DB080403-1-05N: 4 three-pin ports M8, PVC cable 5 m long, NPN NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
33,38 €
excl. VAT · 40,39 € incl. VAT
OUR TIP

DB080403-1-07P, LANBAO, sensor distribution box M8, 4 ports 3pin, PVC 7m, PNP

Cat. no.: DB080403-1-07P

Lanbao passive sensor distribution box DB080403-1-07P: 4 three-pin ports M8, PVC cable 7 m long, PNP NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
33,38 €
excl. VAT · 40,39 € incl. VAT
OUR TIP

DB080403-1-07N, LANBAO, sensor distribution box M8, 4 ports 3pin, PVC 7m, NPN

Cat. no.: DB080403-1-07N

Lanbao passive sensor distribution box DB080403-1-07N: 4 three-pin ports M8, PVC cable 7 m long, NPN NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
33,38 €
excl. VAT · 40,39 € incl. VAT

YG2A14-100UB3XLEAX, CABLE WITH CONNECTOR, 2095768, Sick

Cat. no.: YG2A14-100UB3XLEAX

YG2A14-100UB3XLEAX CABLE WITH CONNECTOR – connection cable with sensor connector, M12, angled, male, 10 m, PUR. Connection cable for industrial sensors and automation equipment.

On request
36,65 €
excl. VAT · 44,34 € incl. VAT
OUR TIP

DB080403-2-05N, LANBAO, sensor distribution box M8, 4 ports 3pin, PUR 5m, NPN

Cat. no.: DB080403-2-05N

Lanbao passive sensor distribution box DB080403-2-05N: 4 three-pin ports M8, PUR cable 5 m long, NPN NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
39,31 €
excl. VAT · 47,57 € incl. VAT
OUR TIP

DB080803-1-03P, LANBAO, sensor distribution box M8, 8 ports 3pin, PVC 3m, PNP

Cat. no.: DB080803-1-03P

Lanbao passive sensor distribution box DB080803-1-03P: 8 three-pin ports M8, PVC cable 3 m long, PNP NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
40,54 €
excl. VAT · 49,05 € incl. VAT
OUR TIP

DB080803-1-03N, LANBAO, sensor distribution box M8, 8 ports 3pin, PVC 3m, NPN

Cat. no.: DB080803-1-03N

Lanbao passive sensor distribution box DB080803-1-03N: 8 three-pin ports M8, PVC cable 3 m long, NPN NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
40,54 €
excl. VAT · 49,05 € incl. VAT
OUR TIP

DB080403-2-07P, LANBAO, sensor distribution box M8, 4 ports 3pin, PUR 7m, PNP

Cat. no.: DB080403-2-07P

Lanbao passive sensor distribution box DB080403-2-07P: 4 three-pin ports M8, PUR cable 7 m long, PNP NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
41,73 €
excl. VAT · 50,50 € incl. VAT
OUR TIP

DB080403-2-07N, LANBAO, sensor distribution box M8, 4 ports 3pin, PUR 7m, NPN

Cat. no.: DB080403-2-07N

Lanbao passive sensor distribution box DB080403-2-07N: 4 three-pin ports M8, PUR cable 7 m long, NPN NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
41,73 €
excl. VAT · 50,50 € incl. VAT
OUR TIP

DB080803-2-03P, LANBAO, sensor distribution box M8, 8 ports 3pin, PUR 3m, PNP

Cat. no.: DB080803-2-03P

Lanbao passive sensor distribution box DB080803-2-03P: 8 three-pin ports M8, PUR cable 3 m long, PNP NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
44,10 €
excl. VAT · 53,37 € incl. VAT
OUR TIP

DB080803-2-03N, LANBAO, sensor distribution box M8, 8 ports 3pin, PUR 3m, NPN

Cat. no.: DB080803-2-03N

Lanbao passive sensor distribution box DB080803-2-03N: 8 three-pin ports M8, PUR cable 3 m long, NPN NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
44,10 €
excl. VAT · 53,37 € incl. VAT
OUR TIP

DB080803-1-05P, LANBAO, sensor distribution box M8, 8 ports 3pin, PVC 5m, PNP

Cat. no.: DB080803-1-05P

Lanbao passive sensor distribution box DB080803-1-05P: 8 three-pin ports M8, PVC cable 5 m long, PNP NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
45,30 €
excl. VAT · 54,81 € incl. VAT
OUR TIP

DB080803-1-05N, LANBAO, sensor distribution box M8, 8 ports 3pin, PVC 5m, NPN

Cat. no.: DB080803-1-05N

Lanbao passive sensor distribution box DB080803-1-05N: 8 three-pin ports M8, PVC cable 5 m long, NPN NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
45,30 €
excl. VAT · 54,81 € incl. VAT
OUR TIP

DB080803-1-07P, LANBAO, sensor distribution box M8, 8 ports 3pin, PVC 7m, PNP

Cat. no.: DB080803-1-07P

Lanbao passive sensor distribution box DB080803-1-07P: 8 three-pin ports M8, PVC cable 7 m long, PNP NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
45,30 €
excl. VAT · 54,82 € incl. VAT
OUR TIP

DB080803-1-07N, LANBAO, sensor distribution box M8, 8 ports 3pin, PVC 7m, NPN

Cat. no.: DB080803-1-07N

Lanbao passive sensor distribution box DB080803-1-07N: 8 three-pin ports M8, PVC cable 7 m long, NPN NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
45,30 €
excl. VAT · 54,82 € incl. VAT
OUR TIP

DB080803-2-05N, LANBAO, sensor distribution box M8, 8 ports 3pin, PUR 5m, NPN

Cat. no.: DB080803-2-05N

Lanbao passive sensor distribution box DB080803-2-05N: 8 three-pin ports M8, PUR cable 5 m long, NPN NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
51,23 €
excl. VAT · 61,99 € incl. VAT
OUR TIP

DB120804-1-03P, LANBAO, sensor distribution box M12, 8 ports 4pin, PVC 3m, PNP

Cat. no.: DB120804-1-03P

Lanbao passive sensor distribution box DB120804-1-03P: 8 four-pin ports M12, PVC cable 3 m long, PNP NO output, 10–30 V, 4 A/port, IP67, LED on each port.

On request
52,42 €
excl. VAT · 63,43 € incl. VAT
OUR TIP

DB120804-1-03N, LANBAO, sensor distribution box M12, 8 ports 4pin, PVC 3m, NPN

Cat. no.: DB120804-1-03N

Lanbao passive sensor distribution box DB120804-1-03N: 8 four-pin ports M12, PVC cable 3 m long, NPN NO output, 10–30 V, 4 A/port, IP67, LED on each port.

On request
52,42 €
excl. VAT · 63,43 € incl. VAT
OUR TIP

DB080803-2-07P, LANBAO, sensor distribution box M8, 8 ports 3pin, PUR 7m, PNP

Cat. no.: DB080803-2-07P

Lanbao passive sensor distribution box DB080803-2-07P: 8 three-pin ports M8, PUR cable 7 m long, PNP NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
53,65 €
excl. VAT · 64,92 € incl. VAT
OUR TIP

DB080803-2-07N, LANBAO, sensor distribution box M8, 8 ports 3pin, PUR 7m, NPN

Cat. no.: DB080803-2-07N

Lanbao passive sensor distribution box DB080803-2-07N: 8 three-pin ports M8, PUR cable 7 m long, NPN NO output, 10–30 V, 2 A/port, IP67, LED on each port.

On request
53,65 €
excl. VAT · 64,92 € incl. VAT

BPI009W, BALLUFF, Sensor box 4xM12/5-pin, BPI 4M4A5P-2K-B0-KPXB0-030

Cat. no.: BPI009W

BPI009W BALLUFF – passive sensor distribution box, M12, 5, angled, female, 3 m, PUR, PNP, PNP. Passive distribution of sensor signals on the machine and in production automation.

On request
55,89 €
excl. VAT · 67,63 € incl. VAT
OUR TIP

DB120804-2-03P, LANBAO, sensor distribution box M12, 8 ports 4pin, PUR 3m, PNP

Cat. no.: DB120804-2-03P

Lanbao passive sensor distribution box DB120804-2-03P: 8 four-pin ports M12, PUR cable 3 m long, PNP NO output, 10–30 V, 4 A/port, IP67, LED on each port.

On request
56,02 €
excl. VAT · 67,79 € incl. VAT
OUR TIP

DB120804-2-03N, LANBAO, sensor distribution box M12, 8 ports 4pin, PUR 3m, NPN

Cat. no.: DB120804-2-03N

Lanbao passive sensor distribution box DB120804-2-03N: 8 four-pin ports M12, PUR cable 3 m long, NPN NO output, 10–30 V, 4 A/port, IP67, LED on each port.

On request
56,02 €
excl. VAT · 67,79 € incl. VAT
OUR TIP

DB120804-1-05P, LANBAO, sensor distribution box M12, 8 ports 4pin, PVC 5m, PNP

Cat. no.: DB120804-1-05P

Lanbao passive sensor distribution box DB120804-1-05P: 8 four-pin ports M12, PVC cable 5 m long, PNP NO output, 10–30 V, 4 A/port, IP67, LED on each port.

On request
57,22 €
excl. VAT · 69,23 € incl. VAT
OUR TIP

DB120804-1-05N, LANBAO, sensor distribution box M12, 8 ports 4pin, PVC 5m, NPN

Cat. no.: DB120804-1-05N

Lanbao passive sensor distribution box DB120804-1-05N: 8 four-pin ports M12, PVC cable 5 m long, NPN NO output, 10–30 V, 4 A/port, IP67, LED on each port.

On request
57,22 €
excl. VAT · 69,23 € incl. VAT

Prices include the recycling fee.

Sensor Cables and Connectors

Design the sensor connection as a whole: from its outlet through the cable and any distribution box to the input of the control system. This group includes, for example, Lanbao cables QE12-N4F2, separate Balluff connectors BCC06Z5 and the box BPI009W. Each solves a different part of the installation. When replacing a component, first note the sensor designation, the wiring of the mating side and the fault that is the reason for changing the connection.

Decision: ready-made connection, custom length or common feed

Cables with Connector choose for a ready-made connection of the matching sensor. If you need to adapt the length to the route and assemble the termination on site, continue with bulk cables and separate connectors. For a group of sensors close together, consider a passive distribution box. Also base the decision on access for servicing: a connector hidden behind a cover can turn a simple replacement into dismantling part of the machine.

Create a table of the actual connections with the columns sensor, port, cable, terminal and PLC input. Mark unused positions as spare. At the next repair it will then be clear whether a cable is missing or the port is intentionally free. For repeated machine assemblies, use the same labelling system, not automatically the same order number.

Principle: connector size is not the whole interface

M8 and M12 do not by themselves describe the electrical wiring. In addition to the number of contacts and male or female design, check the coding and the function of the individual pins. binder manufacturer overview distinguishes, for M12 for example, A-coding for sensor and signal applications, B for PROFIBUS and D or X for Ethernet. The same thread is therefore not proof of interchangeability. Coding helps distinguish mechanical interfaces; the specific supply and signals are defined by the device documentation.

Also separate the question of mechanical connection from system function. A passive box concentrates the cabling, but does not by itself replace an IO-Link master. Balluff explains the role of the master as a communication interface between IO-Link devices and the higher-level bus. The presence of M12 sockets does not prove this function.

Mounting: prepare the route and access to the joint

Measure the length along the planned route, including bends and space for handling. Record separately the sections on moving machine parts, contact with liquids and passage over an edge. For these sections, request the corresponding data of the specific cable. Assess the IP rating according to the documented assembly and its connection conditions; do not determine it from the M8 or M12 designation alone. The mounting documents should also cover the sealing and closing of unused connections.

Author's model example, not a product parameter

Consider six sensors, each with one separate switching signal. The designer can run six separate cables, or combine the signals in a box and continue with a common feed cable. In both cases six corresponding input channels are needed. The box itself does not reduce their number. The choice between the routes is decided by the layout of the sensors and the required access for repairs, not just the number of connectors.

Diagnostics: track where the information is lost

In the event of a fault, separate object detection, output state and transmission to the PLC. Record which of these steps is confirmed. Sensor tester helps with a suitable function test; it does not replace a check of the whole installation. Always change one verified part of the assembly at a time so that the result shows the cause.

FAQ

Is it enough to order the same M12 as before?

First compare the complete interface and wiring of both mating sides. Size is only the first selection criterion.

Can the whole assembly be selected from a photo?

A photo helps with space and outlet direction. For electrical wiring and operating conditions you need the designation and documentation.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.