Phone +420 774 723 123 Cart · 0 · empty

Cam switches

Choice of function, contact program and electrical load of cam switches.

Subcategories

Filters
Found 189 products
OUR TIP

PSA040KS126S, EMAS, Switch standard 0-1-2-3-4-5-6, number of poles 1, current 40A

Cat. no.: PSA040KS126S

PSA040KS126S EMAS - step cam switch, 400V AC, 40A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
57,03 €
excl. VAT · 69,00 € incl. VAT
OUR TIP

PSA050KS134S, EMAS, Switch standard 0-1-2-3-4, number of poles 1, current 50A

Cat. no.: PSA050KS134S

PSA050KS134S EMAS - step cam switch, 400V AC, 50 A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
59,19 €
excl. VAT · 71,62 € incl. VAT
OUR TIP

PSA063KS134S, EMAS, switch standard 0-1-2-3-4, number of poles 1, current 63A

Cat. no.: PSA063KS134S

PSA063KS134S EMAS - step cam switch, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
63,06 €
excl. VAT · 76,31 € incl. VAT
OUR TIP

PSA040KS127S, EMAS, Switch standard 0-1-2-3-4-5-6-7, number of poles 1, current 40A

Cat. no.: PSA040KS127S

PSA040KS127S EMAS - step cam switch, 400V AC, 40A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
63,06 €
excl. VAT · 76,30 € incl. VAT
OUR TIP

PSA050KS135S, EMAS, Switch standard 0-1-2-3-4-5, number of poles 1, current 50A

Cat. no.: PSA050KS135S

PSA050KS135S EMAS - step cam switch, 400V AC, 50 A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
67,66 €
excl. VAT · 81,86 € incl. VAT
OUR TIP

PSA080KS134S, EMAS, switch standard 0-1-2-3-4, number of poles 1, current 80A

Cat. no.: PSA080KS134S

PSA080KS134S EMAS - step cam switch, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
72,48 €
excl. VAT · 87,70 € incl. VAT
OUR TIP

PSA063KS135S, EMAS, Standard switch 0-1-2-3-4-5, No. of poles 1, Current 63A

Cat. no.: PSA063KS135S

PSA063KS135S EMAS - step cam switch, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
72,62 €
excl. VAT · 87,87 € incl. VAT
OUR TIP

PSA050KS126S, EMAS, Standard switch 0-1-2-3-4-5-6, No. of poles 1, Current 50A

Cat. no.: PSA050KS126S

PSA050KS126S EMAS - step cam switch, 400V AC, 50 A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
79,77 €
excl. VAT · 96,52 € incl. VAT
OUR TIP

PSA080KS135S, EMAS, Switch standard 0-1-2-3-4-5, number of poles 1, current 80A

Cat. no.: PSA080KS135S

PSA080KS135S EMAS - step cam switch, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
82,89 €
excl. VAT · 100,30 € incl. VAT
OUR TIP

PSA063KS126S, EMAS, switch standard 0-1-2-3-4-5-6, number of poles 1, current 63A

Cat. no.: PSA063KS126S

PSA063KS126S EMAS - step cam switch, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
85,31 €
excl. VAT · 103,23 € incl. VAT
OUR TIP

PSA050KS127S, EMAS, Switch standard 0-1-2-3-4-5-6-7, number of poles 1, current 50A

Cat. no.: PSA050KS127S

PSA050KS127S EMAS - step cam switch, 400V AC, 50A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
89,54 €
excl. VAT · 108,35 € incl. VAT
OUR TIP

PSA080KS126S, EMAS, Standard switch 0-1-2-3-4-5-6, No. of poles 1, current 80A

Cat. no.: PSA080KS126S

PSA080KS126S EMAS - step cam switch, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
94,69 €
excl. VAT · 114,57 € incl. VAT
OUR TIP

PSA063KS127S, EMAS, Standard switch 0-1-2-3-4-5-6-7, No. of poles 1, Current 63A

Cat. no.: PSA063KS127S

PSA063KS127S EMAS - step cam switch, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
96,21 €
excl. VAT · 116,41 € incl. VAT
OUR TIP

PSA080KS127S, EMAS, Standard switch 0-1-2-3-4-5-6-7, No. of poles 1, Current 80A

Cat. no.: PSA080KS127S

PSA080KS127S EMAS - step cam switch, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
107,52 €
excl. VAT · 130,10 € incl. VAT

Prices include the recycling fee.

Cam switches

Select the cam switch based on the required function, not on the similarity of the handle. Mechanical positions determine what the operator chooses; the contact program determines which circuits are connected in that position. Only then is the electrical load and mounting considered. This approach helps distinguish simple on/off, selection between two options, sequential steps, and specialized motor control.

EMAS orientation

The assortment includes devices such as PSA010KD133S for selection 1–2, PSA010KD134S with the designation 1–0–2, a step PSA016KS132S and PSA020MS335S for star-triangle. They are complemented by the execution of On/Off and PSK boxes. Overview of the PSA series by EMAS differentiates between AK, KD, KS and MS groups; a common series designation does not mean a common scheme.

For two options without a single center zero start with two-position switches 60 °More preselection solutions step cam switchesStarting function belongs to a separate branch. Star-Triangle Switch. Three-position switches 60 ° with zero and On / Off Switches 60 ° corresponds to other requirements for use. Equipment for cam switchesSubcategories are default filter, not confirmation of electrical interchangeability.

Poles, positions and diagrams are three different data

The number of poles describes the number of switched electrical paths. The number of positions describes the possible states of the controller. A single-pole switch can therefore have several positions, while a three-pole switch can only have two. The number of contact terminals, screws, or accessible wires does not necessarily have to match any of these numbers. The information about the angle between positions refers to mechanical movement, not the order of breaking and making contacts.

Read the switching diagram as a map of states: for each position, determine the required connected paths and paths that must remain connected. Consider the transition between positions independently. If the application is not allowed to briefly connect two branches, it must be supported by a detailed transition program. The notation 1–2 alone or the presence of zero is not sufficient to derive all contact overlaps, delays, or auxiliary functions.

What really means current

Compare current at specified working voltage and usage category. Heat current Ith, working current Ie and insulation voltage Ui are not interchangeable. For example EMAS for PSA016AK131S states Ie 16 A and AC21AThis is not a universal power to switch any 16 A engine.

Schneider Electric explains categories by type of load: AC-21 for resistive loads, AC-22 for mixed resistive and inductive loads, and AC-23 for motor or other strongly inductive loads. Suffixes A and B distinguish frequent and less frequent control. AC-23 includes the option to wind individual motors; it does not replace automatic verification of regular motor starting.

What a specific contact actually switches is what matters. Otherwise, it is evaluated as the direct performance circuit, the control input, or the coil. A small steady current does not have to indicate the moment of switching on or off. For the control signal, the contact quality for small loads is also important. Exchanging for higher current capacity alone does not solve all problems.

Include the method of handling in the comparison. Switching at each production cycle creates a different operational requirement than occasional change of settings at a fixed workplace. Record both situations separately, if they can occur on the same device; average frequency can cover short periods of intensive use.

Model example: why amps are not kilowatts of the engine

Choose a symmetrical three-phase system for explanation with 400 V and 16 A current. The calculation √3 × 400 × 16 gives approximately 11,1 kVA apparent power, not the rated power of the motor. If we only model the active power factor as 0,80 and the efficiency as 0,90, we get approximately 8,0 kW mechanical power. Another motor with an active power factor of 0,70 and efficiency of 0,85 would correspond to about 6,6 kW at the same current.

Inputs are chosen for clarity, not for the data provided by the drive. None of the results determine the permissible power of the cam switch: the calculation did not verify the starting current, the starting effort, or the operation frequency. For a specific motor, you need the manufacturer's switching value and the assessment of the entire circuit. The formula explains the difference in magnitudes, not a selection table.

Installation and transmission of supporting documents

Include the full order code, the required contact program, voltage, type of load, operating current, and expected control. Also attach a spatial panel layout: the front dimension is not the depth behind the doors. Account for the device body, access to screws, and cable routing. The number of layers can affect the appropriate box even if the current capacity remains the same.

Check the orientation of the label relative to the mechanism, mechanical will, and availability of the controller. The cover of the part itself cannot be transferred to the finished assembly without further rework after turning the box. The chosen box, mounting, and cable inputs must match the environment. Professional wiring and verification are carried out according to the documentation of the specific product; this guide is not a wiring manual for working on mains voltage.

Frequently asked questions

Is position 0 always safe for maintenance?

No. Operating shutdown and documented disconnection or isolation functions are different requirements. On / Off Safety switches 90 ° it is not possible to derive from the name PL, SIL or a specific characteristic of each product. The documentation and the design of the equipment decide.

Can the apparatus be replaced by a model with the same current and number of poles?

Only after comparison of program, working conditions and mechanical design. The same number of poles does not guarantee the same clamping, order of contacts or the same control.

What should I submit when selecting a replacement?

Readable full part code, original schematic, load characteristics, and mounting dimensions. Photographs of the front side help with identification, but they do not explain the contact program. Before purchasing, compare the function in each required item.

Cookies on this website