PSK12, EMAS, box for main switches, 3-4f 10A-25A
PSK12 EMAS - cabinet for cam switch. Technical specifications, use, assembly and selection of the correct variant.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Choice of function, contact program and electrical load of cam switches.
PSK12 EMAS - cabinet for cam switch. Technical specifications, use, assembly and selection of the correct variant.
PSK21 EMAS - cabinet for cam switch. Technical specifications, use, assembly and selection of the correct variant.
Single pole safety cam switch EMAS PSA010AK141E, 10A, position 0-1, turn 90 °, IP54, front frame 48 × 48mm.
PSK22 EMAS - case for cam switch. Technical specifications, use, assembly and selection of the correct variant.
Single-pole safety cam switch EMAS PSA016AK141E, 16A, position 0-1, turn 90 °, IP54, front frame 48 × 48mm.
PSA020AK131S EMAS - main cam switch 0-1, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.
Single pole safety cam switch EMAS PSA020AK141E, 20A, position 0-1, 90 ° rotation, IP54, front frame 48 × 48mm.
PSA010KS132S EMAS - step cam switch, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA010KD133S EMAS - cam switch 1-2, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA016KS132S EMAS - step cam switch, 400V AC, 16A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA020KS132S EMAS - step cam switch, 400V AC, 20A, IP54. Technical specifications, use, installation and selection of the correct variant.
Three-pole safety cam switch EMAS PSA010AK341E, 10A, control 0-1, 90 °, IP54, front frame 48 × 48mm. For three separately switched poles.
PSA016AK331S EMAS - main cam switch 0-1, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.
Single pole safety cam switch EMAS PSA025AK141E, 25A, position 0-1, 90 ° rotation, IP54, front frame 48 × 48mm.
Three-pole safety cam switch EMAS PSA016AK341E, 16A, control 0-1, 90 °, IP54, front frame 48 × 48mm. For three separately switched poles.
PSA010KS133S EMAS - step cam switch, 400V AC, 10 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA025AK131S EMAS - main cam switch 0-1, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA016KS133S EMAS - step cam switch, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA025KS132S EMAS - step cam switch, 400V AC, 25A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA020AK331S EMAS - main cam switch 0-1, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA010KD234S EMAS - cam switch 1-0-2, 400V AC, 10 A, IP54. Technical specifications, use, assembly and selection of the correct variant.
PSA032AK131S EMAS - main cam switch 0-1, 400V AC, 32A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA020KS133S EMAS - step cam switch, 400V AC, 20 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA016KD234S EMAS - cam switch 1-0-2, 400V AC, 16 A, IP54. Technical specifications, use, installation and selection of the correct variant.
EMAS single-pole safety cam switch PSA032AK141E, 32A, position 0-1, 90 ° rotation, IP54, front frame 64 × 64mm.
Prices include the recycling fee.
Select the cam switch based on the required function, not on the similarity of the handle. Mechanical positions determine what the operator chooses; the contact program determines which circuits are connected in that position. Only then is the electrical load and mounting considered. This approach helps distinguish simple on/off, selection between two options, sequential steps, and specialized motor control.
The assortment includes devices such as PSA010KD133S for selection 1–2, PSA010KD134S with the designation 1–0–2, a step PSA016KS132S and PSA020MS335S for star-triangle. They are complemented by the execution of On/Off and PSK boxes. Overview of the PSA series by EMAS differentiates between AK, KD, KS and MS groups; a common series designation does not mean a common scheme.
For two options without a single center zero start with two-position switches 60 °More preselection solutions step cam switchesStarting function belongs to a separate branch. Star-Triangle Switch. Three-position switches 60 ° with zero and On / Off Switches 60 ° corresponds to other requirements for use. Equipment for cam switchesSubcategories are default filter, not confirmation of electrical interchangeability.
The number of poles describes the number of switched electrical paths. The number of positions describes the possible states of the controller. A single-pole switch can therefore have several positions, while a three-pole switch can only have two. The number of contact terminals, screws, or accessible wires does not necessarily have to match any of these numbers. The information about the angle between positions refers to mechanical movement, not the order of breaking and making contacts.
Read the switching diagram as a map of states: for each position, determine the required connected paths and paths that must remain connected. Consider the transition between positions independently. If the application is not allowed to briefly connect two branches, it must be supported by a detailed transition program. The notation 1–2 alone or the presence of zero is not sufficient to derive all contact overlaps, delays, or auxiliary functions.
Compare current at specified working voltage and usage category. Heat current Ith, working current Ie and insulation voltage Ui are not interchangeable. For example EMAS for PSA016AK131S states Ie 16 A and AC21AThis is not a universal power to switch any 16 A engine.
Schneider Electric explains categories by type of load: AC-21 for resistive loads, AC-22 for mixed resistive and inductive loads, and AC-23 for motor or other strongly inductive loads. Suffixes A and B distinguish frequent and less frequent control. AC-23 includes the option to wind individual motors; it does not replace automatic verification of regular motor starting.
What a specific contact actually switches is what matters. Otherwise, it is evaluated as the direct performance circuit, the control input, or the coil. A small steady current does not have to indicate the moment of switching on or off. For the control signal, the contact quality for small loads is also important. Exchanging for higher current capacity alone does not solve all problems.
Include the method of handling in the comparison. Switching at each production cycle creates a different operational requirement than occasional change of settings at a fixed workplace. Record both situations separately, if they can occur on the same device; average frequency can cover short periods of intensive use.
Choose a symmetrical three-phase system for explanation with 400 V and 16 A current. The calculation √3 × 400 × 16 gives approximately 11,1 kVA apparent power, not the rated power of the motor. If we only model the active power factor as 0,80 and the efficiency as 0,90, we get approximately 8,0 kW mechanical power. Another motor with an active power factor of 0,70 and efficiency of 0,85 would correspond to about 6,6 kW at the same current.
Inputs are chosen for clarity, not for the data provided by the drive. None of the results determine the permissible power of the cam switch: the calculation did not verify the starting current, the starting effort, or the operation frequency. For a specific motor, you need the manufacturer's switching value and the assessment of the entire circuit. The formula explains the difference in magnitudes, not a selection table.
Include the full order code, the required contact program, voltage, type of load, operating current, and expected control. Also attach a spatial panel layout: the front dimension is not the depth behind the doors. Account for the device body, access to screws, and cable routing. The number of layers can affect the appropriate box even if the current capacity remains the same.
Check the orientation of the label relative to the mechanism, mechanical will, and availability of the controller. The cover of the part itself cannot be transferred to the finished assembly without further rework after turning the box. The chosen box, mounting, and cable inputs must match the environment. Professional wiring and verification are carried out according to the documentation of the specific product; this guide is not a wiring manual for working on mains voltage.
No. Operating shutdown and documented disconnection or isolation functions are different requirements. On / Off Safety switches 90 ° it is not possible to derive from the name PL, SIL or a specific characteristic of each product. The documentation and the design of the equipment decide.
Only after comparison of program, working conditions and mechanical design. The same number of poles does not guarantee the same clamping, order of contacts or the same control.
Readable full part code, original schematic, load characteristics, and mounting dimensions. Photographs of the front side help with identification, but they do not explain the contact program. Before purchasing, compare the function in each required item.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.