TH0604B-20, SMC, FEP fluoropolymer tube 6/4 mm, black, roll 20 m
TH0604B-20 SMC – FEP fluoropolymer tube 6/4 mm, black, roll 20 m. The variant is intended for pneumatic distribution according to the stated dimensions and material.
Kurs 24,39 Kč za 1 EUR. Ceny są orientacyjne, rozliczenie następuje w koronach czeskich.
Fluoropolymer FEP tubes resist chemicals and high temperatures and have a smooth inner surface. They are suitable for the food industry, chemicals and laboratories. Choose by diameter, pressure, temperature and medium.
TH0604B-20 SMC – FEP fluoropolymer tube 6/4 mm, black, roll 20 m. The variant is intended for pneumatic distribution according to the stated dimensions and material.
Ceny zawierają opłatę recyklingową.
FEP is the designation of a fluoropolymer material. In the current listing, this category is represented by TH0604B-20 from SMC. Therefore, base the selection on the TH series documentation and the full order code. The name of the material group alone does not determine the permitted operation or the form of connection.
SMC TH table on page 726 assigns model TH0604 an outer diameter of 6 mm and an inner diameter of 4 mm. The letter B designates the black opaque version, the suffix 20 a roll length of 20 m. The manufacturer states fixed use for the series and does not permit it in places where the tube moves.
Draw the parts of the equipment that change position during operation. Easy manual bending does not prove suitability for repeated movement; such a mode must be explicitly permitted by the documentation of the selected version.
For TH0604 the manufacturer states maximum 1.5 MPa at 20 °C or less and 0.55 MPa at 100 °C. The usable limit of the assembly is determined by the lower permitted value of the tube or connection. The media table lists air, water and inert gas; do not assess another medium solely by the name FEP.
For your own specification, create an overview of operating states: cold start, normal operation, maximum temperature and cleaning. Assign pressure and medium to each. Assessing the whole table prevents a state that lasts briefly but is part of the regular working cycle from being overlooked during selection. Also state the measuring point and how the values were obtained, so that the specification can later be compared with reality.
If the machine documentation generally states a fluoropolymer, add the exact material designation. The compared Teflon tubes assess according to its own manufacturing sheet. Do not consider the same size or a similar colour as a basis for approving a replacement.
For our own tutorial model, let us choose a route with two straight sections of 120 mm each and one right-angle arc whose radius measured to the line axis is 50 mm. The arc length is π × 50 / 2 = approximately 78.5 mm. The whole geometric route therefore measures 120 + 78.5 + 120 = 318.5 mm.
This is design geometry with arbitrarily chosen inputs, not a prescribed radius or finished cutting length of a product. The calculation does not include insertion into fittings. Before cutting, compare the chosen bend with the documentation of the exact tube and add mounting lengths according to the connection drawing. When the supply position changes, recalculate the whole route.
Add support points, access to joints and the prescribed test procedure to the mounting plan. Select a tool for preparing the ends in the category Cutting pliers, knives only after verifying its suitability for the given material. Document the handover with a photo of the actual route.
As our own diagnostic procedure, in case of problems we recommend comparing actual operation with the specified table of states. Record where the problem appeared and whether it was preceded by heating, cleaning or intervention in the line. Then check the relevant section according to the manufacturer's instructions; simply increasing the clamping force or randomly changing the material is not a documented solution to the cause.
Attach the full code, a route sketch and a table of media, pressures and temperatures. Add the required quantity and packaging method.
You need the value at the actual temperature, the specified medium and the connection conditions. An overview of other material branches can be found in the category Pneumatic tubes.
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.