LA33LUM320, EMAS, safety actuator key, safety key, for L5 / L51 / L52 / L53
LA33LUM320 EMAS – safety actuator key. Technical parameters, application and compatibility check.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
EMAS safety limit switches – key-operated, hinge, rope pull and magnetic with positive opening contacts for monitoring protective guards. Choose by type of protective guard and safety function.
LA33LUM320 EMAS – safety actuator key. Technical parameters, application and compatibility check.
LA33LUM321 EMAS – safety actuator key. Technical parameters, application and compatibility check.
Z70 EMAS – lift door contact. Technical parameters, application and compatibility check.
Z73 EMAS – lift door contact. Technical parameters, application and compatibility check.
Z74 EMAS – lift door contact. Technical parameters, application and compatibility check.
LA33LUM323 EMAS – safety actuator key. Technical parameters, application and compatibility check.
Z71 EMAS – lift door contact. Technical parameters, application and compatibility check.
Z72 EMAS – lift door contact. Technical parameters, application and compatibility check.
LA33LUM324 EMAS – safety actuator key. Technical parameters, application and compatibility check.
L5K23LUM322 EMAS – safety limit switch, L5, safety actuator - straight key, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L5K23LUM321 EMAS – safety limit switch, L5, safety actuator - bent key, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L5K23LEM411 EMAS – hinge safety switch, L5, hinge actuator, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L5K23LEM621 EMAS – hinge safety switch, L5, hinge actuator, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L5K23LEM412 EMAS – hinge safety switch, L5, hinge actuator, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L5K23LEM622 EMAS – hinge safety switch, L5, hinge actuator, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L5K27LUM321 EMAS – safety limit switch, L5, safety actuator - bent key, 1 NC + 2 NO, slow action. Technical parameters, application and compatibility check.
L5K25LUM322 EMAS – safety limit switch, L5, safety actuator - straight key, 2 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L51K13HUM111 EMAS – safety limit switch, L51, rope / ring actuator, 1 NC + 1 NO, snap action. Technical parameters, application and compatibility check.
L52K23HUM111 EMAS – safety limit switch, L52, rope / ring actuator, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L51K23HUM112 EMAS – safety limit switch, L51, rope / ring actuator with reset, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L52K23HUM112 EMAS – safety limit switch, L52, rope / ring actuator with reset, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
iE110-PL030 iE – safety rope. Technical parameters, application and compatibility check.
ie110-peb iE – mounting eye / bolt. Technical parameters, application and compatibility check.
L5K23LEM511 EMAS – hinge safety switch, L5, hinge actuator, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
L5K23BEM621 EMAS – hinge safety switch, L5, rotary tubular hinge actuator, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.
Prices include the recycling fee.
A safety limit switch is selected as part of a specific protective function, not as a stand-alone guarantee of a safe machine. First determine which state is to be detected, how the equipment reacts to it and whether hazardous movement persists after the guard position changes. Detecting the opening alone does not keep the door closed and is not equivalent to locking it against opening during run-down.
The range includes, for example, EMAS L5K23LUM322 with a straight key, hinge versions L5K23LEM411 and L5K23LEM621 and the rope-pull L51K23HUM111. For the key-operated model L5K23LUM322 the manufacturer confirms a plastic body, slow action and 1NO + 1NC. The design distinction is documented by the EMAS L5 series overview.
With a key-operated design, assess above all the alignment of the counterpart and the entry. With a hinge switch, the direction of rotation, position of the axis and transmission of door movement are decisive. A rope-pull version is not selected just by the length of the area: it must match the required function, tension, reset method and the manufacturer's rules for the whole assembly. Monitoring of rope breakage cannot automatically be inferred from the designation "rope-pull".
Positive opening means mechanically forced separation of the relevant contacts under specified conditions. Ordinary switching on contact with the cam is not enough; the prescribed travel or force must also be observed. The significance of these conditions is described in the OMRON technical explanation. For the selected product, check the marking and documentation of the specific contact.
Snap-action and slow-action mechanisms describe the course of switching, not the resulting safety level. A snap-action mechanism can also have positive opening if it is designed that way; an example is given by OMRON for safety snap-action contacts. However, this property does not carry over to other products or any heads of the same series.
Consider an ideally rigid door 600 mm wide and a model change of angle by 3°. A point on its outer edge travels along a circle approximately s = r × φ = 600 × 3π / 180 = 31.4 mm. The same angle on a shorter door would mean a different distance. Three degrees is only the author's assumption, not the switching angle of any listed model.
The result is not an assessment of the access gap or the safety distance. It shows why a hinge switch is evaluated in the geometry of the specific guard. Hinge play, sheet metal flexibility and the position of the monitored point can influence the actual course of opening; they must be included in the design and subsequent verification.
Do not use the switch or the key as a mechanical door stop. The fastening must maintain the geometry even with repeated closing and limit the possibility of bypassing the protection. After repair, verify all required states including restart. For a contactless alternative, see Magnetic Sensors; their safety suitability is assessed separately. A broader overview is provided by the category Limit Switches.
Keep the exact designation of the switch and the actuating counterpart in the service documentation. A replacement based only on the hole spacing may change the contact sequence or the required movement. Verification of the assembly must also follow hinge adjustment and any change to the guard fastening.
No. The number of contacts alone does not prove diagnostics, fault tolerance or the resulting properties of the entire safety system.
The answer must follow from the risk assessment and the control design. The information "guard closed" and a restart command are not automatically the same event.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.