Phone +420 774 723 123 Cart · 0 · empty

Branch fittings

Branch push-in fittings – T-pieces, Y-pieces and multiple manifolds – for branching the pneumatic line. Choose by tube diameter and shape.

Filters
Found 54 products

KQ2T12-00A, SMC, T-connector, 3× tube Ø12mm

Cat. no.: KQ2T12-00A

KQ2T12-00A, SMC, T-connector, 3× tube Ø12mm. Branching into three pneumatic branches; the flow is divided according to consumption and line resistance.

On request
7,57 €
excl. VAT · 9,16 € incl. VAT

KQ2TW06-00A, SMC, cross fitting, 4× tube Ø6mm

Cat. no.: KQ2TW06-00A

KQ2TW06-00A, SMC, cross fitting, 4× tube Ø6mm. Cross connection of four pneumatic branches at a single point.

On request
8,15 €
excl. VAT · 9,86 € incl. VAT

KQ2U10-12A, SMC, Y-connector, reducer Ø10mm↔Ø12mm

Cat. no.: KQ2U10-12A

KQ2U10-12A, SMC, Y-connector, reducer Ø10mm↔Ø12mm. Angled Y-branching for routing three branches with suitable tube geometry.

On request
8,60 €
excl. VAT · 10,40 € incl. VAT

KQ2U12-16A, SMC, Y-connector, reducer Ø12mm↔Ø16mm

Cat. no.: KQ2U12-16A

KQ2U12-16A, SMC, Y-connector, reducer Ø12mm↔Ø16mm. Angled Y-branching for routing three branches with suitable tube geometry.

On request
11,87 €
excl. VAT · 14,36 € incl. VAT

Prices include the recycling fee.

Branch fittings

Select a branch fitting according to the number and direction of the required branches. The range includes T and Y shapes, cross versions, manifolds, miniature and all-metal variants and SMC items. For the design, it is essential to draw the actual ports; the designation Y-connector may not describe the whole distribution plan you want to create.

Pneuflex for PE describes the connection of three tubes of the same size in a T arrangement. PY family connects three tubes of the same size in a Y arrangement. PZA family has four tube connections.

Draw the ports before dividing the consumers

Our own selection procedure starts with a map: each port gets a designation, connection type and size. Then assign the individual consumers and their working phases. For consumers along the same route, consider a Y spatial arrangement; for a side branch, assess a T. If the branch sizes differ, open Reducing fittings and mark which port needs a change. Such a map is more specific than ordering by a pair of numbers.

In your own assessment of the distribution, distinguish the number of connected consumers and the number of consumers running simultaneously. Also write the required behaviour when one branch is replaced into the specification. Whether the rest of the equipment should continue in operation is a decision about the whole diagram. If you only need a change of direction without a new branch, compare Elbow fittings.

Pneuflex for PK describes the division of the supply into three side tube connections of the same size. For your own sketch, mark each port, including the common supply. The number of branches served is then not confused with the total number of interfaces. When designing the assembly, record whether the common route should end or continue at the given point; this choice must be addressed by the specific diagram and part documentation.

Our own model of simultaneous consumption

Let us assume three model consumers with consumption of 75, 110 and 90 litres per minute. For this calculation, all values are deliberately expressed at the same reference conditions. With full simultaneity, the sum is 75 + 110 + 90 = 275 litres per minute. With a controlled sequence that allows only one consumer to work at a time, the highest of the considered instantaneous consumptions is 110 litres per minute. This is our own balance example, not the flow rate of a fitting. The pressure loss of the distribution cannot be determined from the result; however, it shows why the selection specification must include time simultaneity, not just a list of connected equipment.

Mounting, marking and access

Prepare the work for a safely secured and depressurised affected section. For your own mounting check, transfer the port designations from the sketch to the individual lines and verify the space for replacing each branch. For an assembly with multiple ports, go through the service operations one by one; access to the front tube alone is not enough. If the distribution passes through a structural bulkhead, address this point separately via Bulkhead fittings.

Pneuflex for PE describes connecting by insertion and disconnecting by pressing the collet. When mounting a branch fitting, assess this action for each port separately.

Diagnostics of one branch and the common supply

Your own service record should distinguish a problem of one consumer from a symptom during simultaneous operation of several branches. Compare the same working phases and record which branches were active. A symptom only during simultaneous operation is a reason to verify the common part of the distribution; replacing the last Y-connector alone would not explain the cause. If the problem follows a specific branch, check its route, counterparts and completeness of the selection record.

FAQ

Does a T-fitting divide the flow evenly?

For the design, do not assume uniformity from the shape alone. Specify consumption, branch lengths and their working conditions; the distribution must be assessed for the actual layout.

Can T and Y be interchanged based on the same size?

First redraw all ports and the line route. Dimensional match is only part of the selection; orientation and service access in the assembly are also decisive.

Cookies on this website