Phone +420 774 723 123 Cart · 0 · empty

Straight fittings

Straight push-in fittings for joining two tubes in one axis or a tube to a thread. Choose by tube diameter.

Filters
Found 66 products
OUR TIP

KQ2H08-10A, SMC, straight fitting, reducer Ø8mm↔Ø10mm

Cat. no.: KQ2H08-10A

KQ2H08-10A, SMC, straight fitting, reducer Ø8mm↔Ø10mm. Straight connection of two tubes; suitable for extending a pneumatic route without a thread.

On request
4,87 €
excl. VAT · 5,89 € incl. VAT
OUR TIP

KQ2H12-00A, SMC, straight fitting, 2× tube Ø12mm

Cat. no.: KQ2H12-00A

KQ2H12-00A, SMC, straight fitting, 2× tube Ø12mm. Straight connection of two tubes; suitable for extending a pneumatic route without a thread.

On request
5,12 €
excl. VAT · 6,19 € incl. VAT

KQ2S12-02NS, SMC, straight fitting with internal hexagon, tube Ø12mm, male R1/4

Cat. no.: KQ2S12-02NS

KQ2S12-02NS, SMC, straight fitting with internal hexagon, tube Ø12mm, male R1/4. Straight connection of the tube to threaded port R1/4; the thread seal must be verified.

On request
5,32 €
excl. VAT · 6,44 € incl. VAT

KQ2E06-03A, SMC, bulkhead fitting, tube Ø6mm, female Rc3/8

Cat. no.: KQ2E06-03A

KQ2E06-03A, SMC, bulkhead fitting, tube Ø6mm, female Rc3/8. Fixed pass-through of a pneumatic line through a mounting plate or cabinet wall.

On request
5,32 €
excl. VAT · 6,44 € incl. VAT
OUR TIP

KQ2H06-08A, SMC, straight fitting, reducer Ø6mm↔Ø8mm

Cat. no.: KQ2H06-08A

KQ2H06-08A, SMC, straight fitting, reducer Ø6mm↔Ø8mm. Straight connection of two tubes; suitable for extending a pneumatic route without a thread.

On request
5,45 €
excl. VAT · 6,59 € incl. VAT

KQ2E06-00A, SMC, bulkhead fitting, tube Ø6mm on both sides

Cat. no.: KQ2E06-00A

KQ2E06-00A, SMC, bulkhead fitting, tube Ø6mm on both sides. Fixed pass-through of a pneumatic line through a mounting plate or cabinet wall.

On request
5,53 €
excl. VAT · 6,69 € incl. VAT

KQ2E08-02A, SMC, bulkhead fitting, tube Ø8mm, female Rc1/4

Cat. no.: KQ2E08-02A

KQ2E08-02A, SMC, bulkhead fitting, tube Ø8mm, female Rc1/4. Fixed pass-through of a pneumatic line through a mounting plate or cabinet wall.

On request
5,94 €
excl. VAT · 7,18 € incl. VAT

KQ2E08-00A, SMC, bulkhead fitting, tube Ø8mm on both sides

Cat. no.: KQ2E08-00A

KQ2E08-00A, SMC, bulkhead fitting, tube Ø8mm on both sides. Fixed pass-through of a pneumatic line through a mounting plate or cabinet wall.

On request
6,34 €
excl. VAT · 7,68 € incl. VAT
OUR TIP

KQ2H10-12A, SMC, straight fitting, reducer Ø10mm↔Ø12mm

Cat. no.: KQ2H10-12A

KQ2H10-12A, SMC, straight fitting, reducer Ø10mm↔Ø12mm. Straight connection of two tubes; suitable for extending a pneumatic route without a thread.

On request
6,62 €
excl. VAT · 8,01 € incl. VAT

KCJ08-99, SMC, plug-in stem with check valve, stem Ø8mm

Cat. no.: KCJ08-99

KCJ08-99, SMC, plug-in stem with check valve, stem Ø8mm. A self-sealing joint for disconnectable pneumatic assemblies; requires the correct counterpart.

On request
7,78 €
excl. VAT · 9,41 € incl. VAT

KCH08-00, SMC, self-sealing straight fitting, tube Ø8mm

Cat. no.: KCH08-00

KCH08-00, SMC, self-sealing straight fitting, tube Ø8mm. A self-sealing joint for disconnectable pneumatic assemblies; requires the correct counterpart.

On request
8,60 €
excl. VAT · 10,40 € incl. VAT

KQ2E10-00A, SMC, bulkhead fitting, tube Ø10mm on both sides

Cat. no.: KQ2E10-00A

KQ2E10-00A, SMC, bulkhead fitting, tube Ø10mm on both sides. Fixed pass-through of a pneumatic line through a mounting plate or cabinet wall.

On request
9,82 €
excl. VAT · 11,89 € incl. VAT

KQ2E12-00A, SMC, bulkhead fitting, tube Ø12mm on both sides

Cat. no.: KQ2E12-00A

KQ2E12-00A, SMC, bulkhead fitting, tube Ø12mm on both sides. Fixed pass-through of a pneumatic line through a mounting plate or cabinet wall.

On request
11,67 €
excl. VAT · 14,12 € incl. VAT

KQ2E12-03A, SMC, bulkhead fitting, tube Ø12mm, female Rc3/8

Cat. no.: KQ2E12-03A

KQ2E12-03A, SMC, bulkhead fitting, tube Ø12mm, female Rc3/8. Fixed pass-through of a pneumatic line through a mounting plate or cabinet wall.

On request
11,71 €
excl. VAT · 14,17 € incl. VAT

KCE06-00, SMC, self-sealing bulkhead fitting, tube Ø6mm

Cat. no.: KCE06-00

KCE06-00, SMC, self-sealing bulkhead fitting, tube Ø6mm. A self-sealing joint for disconnectable pneumatic assemblies; requires the correct counterpart.

On request
13,10 €
excl. VAT · 15,85 € incl. VAT

KM11-04-08-10, SMC, distribution block, 10× outlet Ø4mm / inlet Ø8mm

Cat. no.: KM11-04-08-10

KM11-04-08-10, SMC, distribution block, 10× outlet Ø4mm / inlet Ø8mm. A multi-way compressed air distributor for clear connection of consumer branches.

On request
20,26 €
excl. VAT · 24,52 € incl. VAT

Prices include the recycling fee.

Straight fittings

A straight fitting is a suitable starting shape where you want to route the connection in one axis. However, when selecting, distinguish between connecting two tubes and a transition between a tube and a threaded port. The public range includes standard, miniature and all-metal Pneuflex versions and several SMC series. The word straight alone is therefore not enough to order the counterpart.

Pneuflex describes the PU family as a coaxial connection of two tubes with the same outer diameter. SMC states KQ2H06-00A among straight fittings for two tubes with an outer diameter of 6 mm.

Record the two ends separately

For your own selection sheet, create two columns. In each, determine the interface type and size; add the full designation for the thread. Only then compare the material version and documented operating conditions of the specific item. If one interface has a different size, continue via Reducing fittings. If you need to change direction right at the port, also assess Elbow fittings.

Our own decision question is: should the fitting remain loose between two lines, or does it need a fixed place in the structure? For a fixed pass-through, the relevant branch is Bulkhead fittings. Do not try to decide only on the basis of a photo or the colour of the release ring. You need a drawn interface, the available space and an idea of which part of the assembly you will change later.

When repairing a damaged section, mark which parts of the line should remain and which you will replace. Inserting a new piece between preserved ends is a different assembly than replacing the whole line between the original connections. Compare both variants by access, number of new connections and the possibility of future replacement. Prepare the length sketch for the selected variant before ordering parts.

Verify the length in the assembled state

For the mounting plan, distinguish the length of cut pieces, the length of the fitting body and the lengths hidden inside the connection. These quantities have different measurement origins. Therefore mark the faces and reference points in the sketch. I suggest carrying out your own check first on one sample assembly: compare the design dimensions with the actual arrangement and verify the space for service. When measuring, also take into account the routing of the line in the planned holders.

Our own model length calculation

Let us consider two separate pieces of model tube 100 and 140 mm long. The hypothetical fitting has a length of 30 mm between the faces and we consider an insertion of 12 mm on each side. The total length from the free end of the first tube to the free end of the second is 100 + 140 + 30 − 12 − 12 = 246 mm. The inputs are our own assumptions, not dimensions of the offered product. If we subtracted the insertion only once, the design would differ by 12 mm. The example shows the importance of common reference points; for an actual fitting, use the data from its drawing.

Mounting and distinguishing a fault

Plan the work for a safely secured system without pressure in the affected section. As part of your own acceptance, compare the position of the fitting before and after routing the line. Record whether both pieces connect naturally in one axis, or whether the holders force a lateral offset. In diagnostics, separate a fault of one tube end from a problem of the threaded connection. Carry out the comparison test under the same conditions and record what actually changed after each change.

Pneuflex for PU describes inserting the tube directly into the fitting; pressing the release collet is used for removal. Verify access to this operation even after both lines are fixed.

FAQ

Can a straight fitting solve a lateral offset?

Draw the actual line axes in the design. Choose a straight shape only after verifying that the required route can be assembled without forced deflection at the connection.

Is a shorter body automatically more advantageous?

Compare the whole assembly including access to both ends. Dimensional savings are of practical importance when they preserve the planned mounting and later replacement of the line.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.