Phone +420 774 723 123 Cart · 0 · empty

Power Supplies

Power supplies for automation, control cabinets and machines – 5, 12, 24 and 48 V DC switched-mode supplies for DIN rail and panel mounting from MEAN WELL, Siemens, Omron, Balluff, IDEC and others. Choose by output voltage and current with reserve, supply network, dimensions and operating temperature.

Subcategories

Filters
Found 330 products

PS5R-VD24, IDEC, switched-mode DIN-rail power supply, 60W, 24VDC/2.5A

Cat. no.: PS5R-VD24

PS5R-VD24, IDEC – compact switched-mode power supply of the PS5R-V series for DIN rail, 60W, 24VDC/2.5A, input 100–240VAC. Width 36mm. For PLCs, HMIs, sensors, relays and other industrial automation…

On request
78,36 €
excl. VAT · 94,81 € incl. VAT

6EP1332-2BA20, Siemens SITOP PSU100S – regulated power supply 24 V DC / 2.5 A

Cat. no.: 6EP1332-2BA20

6EP1332-2BA20 Siemens SITOP PSU100S is a regulated power supply with an output of 24 V DC / 2.5 A and a version for single-phase AC input. Designed for standard to more demanding machines and control…

On request
78,92 €
excl. VAT · 95,50 € incl. VAT

6EP1322-1LD01, Siemens SITOP PSU100D – regulated power supply 12 V DC / 8.5 A

Cat. no.: 6EP1322-1LD01

6EP1322-1LD01 Siemens SITOP PSU100D is a regulated power supply with an output of 12 V DC / 8.5 A and a version for single-phase AC input. Designed for machines, equipment and enclosures where…

On request
78,92 €
excl. VAT · 95,50 € incl. VAT

S8FS-C15024 OMRON – power supply S8FS-C, 150 W, 24 V DC / 6.5 A

Cat. no.: S8FS-C15024

S8FS-C15024 OMRON is an industrial power supply of the S8FS-C. series with a power of 150 W, an output of 24 V DC and a rated current of 6.5 A. Version: Built-in / direct mounting. Supply / phase…

On request
79,56 €
excl. VAT · 96,27 € incl. VAT

S8FS-C15024J OMRON – power supply S8FS-C, 150 W, 24 V DC / 6.5 A

Cat. no.: S8FS-C15024J

S8FS-C15024J OMRON is an industrial power supply of the S8FS-C. series with a power of 150 W, an output of 24 V DC and a rated current of 6.5 A. Version: Built-in / direct mounting. Supply / phase…

On request
79,56 €
excl. VAT · 96,27 € incl. VAT

S8VK-S03024 OMRON – power supply S8VK-S, 30 W, 24 V DC / 1.3 A

Cat. no.: S8VK-S03024

S8VK-S03024 OMRON is an industrial power supply of the S8VK-S. series with a power of 30 W, an output of 24 V DC and a rated current of 1.3 A. Version: DIN, coated. Supply / phase: 1f. Connection…

On request
80,48 €
excl. VAT · 97,39 € incl. VAT

S8FS-G03012CD OMRON – power supply S8FS-G, 30 W, 12 V DC / 3 A

Cat. no.: S8FS-G03012CD

S8FS-G03012CD OMRON is an industrial power supply of the S8FS-G. series with a power of 30 W, an output of 12 V DC and a rated current of 3 A. Version: Built-in / DIN. Supply / phase: 1f. Connection…

On request
82,08 €
excl. VAT · 99,32 € incl. VAT

S8FS-G03024CD OMRON – power supply S8FS-G, 30 W, 24 V DC / 1.5 A

Cat. no.: S8FS-G03024CD

S8FS-G03024CD OMRON is an industrial power supply of the S8FS-G. series with a power of 30 W, an output of 24 V DC and a rated current of 1.5 A. Version: Built-in / DIN. Supply / phase: 1f…

On request
82,08 €
excl. VAT · 99,32 € incl. VAT

S8VK-G03005 OMRON – power supply S8VK-G, 30 W, 5 V DC / 5 A

Cat. no.: S8VK-G03005

S8VK-G03005 OMRON is an industrial power supply of the S8VK-G. series with a power of 30 W, an output of 5 V DC and a rated current of 5 A. Version: Pro, DIN rail. Supply / phase: 1f. Connection…

On request
82,81 €
excl. VAT · 100,20 € incl. VAT

S8VK-G03012 OMRON – power supply S8VK-G, 30 W, 12 V DC / 2.5 A

Cat. no.: S8VK-G03012

S8VK-G03012 OMRON is an industrial power supply of the S8VK-G. series with a power of 30 W, an output of 12 V DC and a rated current of 2.5 A. Version: Pro, DIN rail. Supply / phase: 1f. Connection…

On request
82,81 €
excl. VAT · 100,20 € incl. VAT

S8VK-G03024 OMRON – power supply S8VK-G, 30 W, 24 V DC / 1.3 A

Cat. no.: S8VK-G03024

S8VK-G03024 OMRON is an industrial power supply of the S8VK-G. series with a power of 30 W, an output of 24 V DC and a rated current of 1.3 A. Version: Pro, DIN rail. Supply / phase: 1f. Connection…

On request
82,81 €
excl. VAT · 100,20 € incl. VAT

6EP1333-1LD01, Siemens SITOP PSU100D – regulated power supply 24 V DC / 6.25 A

Cat. no.: 6EP1333-1LD01

6EP1333-1LD01 Siemens SITOP PSU100D is a regulated power supply with an output of 24 V DC / 6.25 A and a version for single-phase AC input. Designed for machines, equipment and enclosures where…

On request
84,04 €
excl. VAT · 101,69 € incl. VAT

S8FS-C15012 OMRON – power supply S8FS-C, 150 W, 12 V DC / 12.5 A

Cat. no.: S8FS-C15012

S8FS-C15012 OMRON is an industrial power supply of the S8FS-C. series with a power of 150 W, an output of 12 V DC and a rated current of 12.5 A. Version: Built-in / direct mounting. Supply / phase…

On request
84,29 €
excl. VAT · 101,99 € incl. VAT

BAE0113, BALLUFF, power supply 24VDC/10A, 240W, 1f, DIN rail

Cat. no.: BAE0113

BAE0113 BALLUFF is an industrial power supply 24VDC/10A with a power of 240W. Version: single-phase input 100–240VAC, IP20, DIN-rail mounting. Suitable for industrial automation, machines and control…

On request
88,13 €
excl. VAT · 106,63 € incl. VAT

S8FS-G05024C OMRON – power supply S8FS-G, 50 W, 24 V DC / 2.2 A

Cat. no.: S8FS-G05024C

S8FS-G05024C OMRON is an industrial power supply of the S8FS-G. series with a power of 50 W, an output of 24 V DC and a rated current of 2.2 A. Version: Built-in / direct mounting. Supply / phase…

On request
88,20 €
excl. VAT · 106,73 € incl. VAT

6EP1332-5BA10, Siemens SITOP PSU100C – regulated power supply 24 V DC / 4 A

Cat. no.: 6EP1332-5BA10

6EP1332-5BA10 Siemens SITOP PSU100C is a regulated power supply with an output of 24 V DC / 4 A and a version for single-phase AC input. Designed for small machines, distribution cabinets, sensors…

On request
89,88 €
excl. VAT · 108,76 € incl. VAT
OUR TIP

BAE0115, BALLUFF, power supply 24VDC/5A, 120W, 3f, DIN rail

Cat. no.: BAE0115

BAE0115 BALLUFF is an industrial power supply 24VDC/5A with a power of 120W. Version: IP20, DIN rail. Suitable for industrial automation, machines and control cabinets.

On request
90,59 €
excl. VAT · 109,61 € incl. VAT
OUR TIP

BAE0115, BALLUFF, power supply 24VDC/5A, 120W, 3f, DIN rail

Cat. no.: BAE0115

BAE0115 BALLUFF is an industrial power supply 24VDC/5A with a power of 120W. Version: IP20, DIN rail. Suitable for industrial automation, machines and control cabinets.

On request
90,59 €
excl. VAT · 109,61 € incl. VAT

S8VK-C12024 OMRON – power supply S8VK-C, 120 W, 24 V DC / 5 A

Cat. no.: S8VK-C12024

S8VK-C12024 OMRON is an industrial power supply of the S8VK-C. series with a power of 120 W, an output of 24 V DC and a rated current of 5 A. Version: Lite, DIN rail. Supply / phase: 1f. Connection…

On request
91,86 €
excl. VAT · 111,15 € incl. VAT

S8FS-G05012CD OMRON – power supply S8FS-G, 50 W, 12 V DC / 4.3 A

Cat. no.: S8FS-G05012CD

S8FS-G05012CD OMRON is an industrial power supply of the S8FS-G. series with a power of 50 W, an output of 12 V DC and a rated current of 4.3 A. Version: Built-in / DIN. Supply / phase: 1f…

On request
92,78 €
excl. VAT · 112,27 € incl. VAT

S8FS-G05024CD OMRON – power supply S8FS-G, 50 W, 24 V DC / 2.2 A

Cat. no.: S8FS-G05024CD

S8FS-G05024CD OMRON is an industrial power supply of the S8FS-G. series with a power of 50 W, an output of 24 V DC and a rated current of 2.2 A. Version: Built-in / DIN. Supply / phase: 1f…

On request
92,78 €
excl. VAT · 112,27 € incl. VAT

6EP1322-5BA10, Siemens SITOP PSU100C – regulated power supply 12 V DC / 6.5 A

Cat. no.: 6EP1322-5BA10

6EP1322-5BA10 Siemens SITOP PSU100C is a regulated power supply with an output of 12 V DC / 6.5 A and a version for single-phase AC input. Designed for small machines, distribution cabinets, sensors…

On request
92,81 €
excl. VAT · 112,30 € incl. VAT

PS5R-VE24, IDEC, switched-mode DIN-rail power supply, 90W, 24VDC/3.75A

Cat. no.: PS5R-VE24

PS5R-VE24, IDEC – compact switched-mode power supply of the PS5R-V series for DIN rail, 90W, 24VDC/3.75A, input 100–240VAC. Width 36mm. For PLCs, HMIs, sensors, relays and other industrial automation…

On request
93,22 €
excl. VAT · 112,79 € incl. VAT

NDR-480-24, Mean Well, switched-mode DIN-rail power supply, 24VDC/20A, 480W

Cat. no.: NDR-480-24

NDR-480-24 Mean Well – switched-mode power supply of the NDR-480 series for DIN rail, 480W, 24VDC/20A, input 90–264VAC. Suitable for industrial control cabinets, PLCs, HMIs, sensors, relays and other…

On request
96,28 €
excl. VAT · 116,50 € incl. VAT
OUR TIP

DRA480-24A-X, Chinfa, power supply; voltage: 24V DC; output power: 480W; output current: 20A, 90 - 264V AC, 24 A, 480 W

Cat. no.: DRA480-24A-X

DRA480-24A-X Chinfa – power supply; voltage: 24V DC; output power: 480W; output current: 20A, 90 - 264V AC, 24 A, 480 W. Key data: 50 - 63Hz. Exact technical data for selecting the switched-mode…

On request
96,60 €
excl. VAT · 116,88 € incl. VAT

Prices include the recycling fee.

Power supplies

Choose a power supply as part of the entire supply circuit: from the mains feed through the control cabinet to the terminals of the most distant load. The correct output voltage is the first condition, not full confirmation of compatibility. The current during normal operation and start-up, the temperature inside the enclosure, protection, mounting method and the requirements of the connected equipment for protective separation are also decisive.

What this branch includes

The catalogue divides the range into the categories Allen-Bradley power supplies, IDEC 5/12/24V DC power supplies, CHINFA 12/24V DC power supplies, PULS 24V DC power supplies, Rievtech power supplies and Siemens power supplies. Catalogue items include, for example, CHINFA DRS1-24A and DRS5-24A, PULS PIC120.241C, Rievtech RPS-60-24 and several Siemens order codes. The parameters of these products are not common parameters of the whole category. The existence of the branch also does not confirm the availability of a specific type.

How a switched-mode regulated power supply works

A switched-mode power supply converts input energy using a rapidly switched power circuit; feedback adjusts the operation so that the output holds the required voltage within the permitted limits. Output filtering limits ripple but does not eliminate all transients. The basic difference from a linear power supply is described in the IDEC technical FAQ. For sensitive analogue measurement, therefore check not only the rated voltage but also the ripple, permissible interference and the routing of common return conductors.

Continuous load, simultaneity and peaks

List all loads by voltage branch. For each, record the highest operating current, short-term consumption, its duration and when it occurs. Do not calculate the coil current from the current capacity of its contacts; the figure on a relay output is not the relay's consumption. For equipment with externally powered outputs, check whether the documented consumption also includes the connected loads. Do not count the same current twice.

The required continuous current is determined by the worst permissible simultaneous operation, not by the average over a shift. Compare the peak with the overload characteristic of the selected power supply, including its duration and repetition. The boost designation alone is not enough. Design the reserve according to expansion and actual operating uncertainties; a universal percentage does not replace assessment of the start-up.

Model example of a current balance

Consider a hypothetical 24 V branch: the controller draws 0.45 A, the panel 0.35 A, eight sensors 0.03 A each and four simultaneously energised coils 0.12 A each. The sum is 1.52 A, i.e. 36.48 W. If the panel needs 1.10 A instead of 0.35 A at switch-on for 80 ms, the simultaneous consumption rises to 2.27 A. These are chosen inputs for the example, not data of the devices offered.

A power supply with a rated current of 2 A cannot be approved from the first sum alone, nor automatically rejected from the second: the permissible time characteristic and the voltage drop will decide. If we do not know it, we do not assume a short-term reserve. Delaying some loads can only help if their sequence is also ensured after the power supply is restored.

Derating, losses and space in the control cabinet

Derating means reducing the permissible load under specified conditions. It may relate to ambient temperature, altitude or a different mounting position; the curve of the specific type is decisive, as explained in the PULS guide to derating. The upper operating temperature is not automatically the temperature for full power. Assess the air at the power supply, not just the room temperature.

Your own design check should include the width on the rail, the depth including terminals, conductor bending and the prescribed ventilation clearances. Losses also belong in the heat balance. As a model, with an output of 100 W and an assumed efficiency of 90 %, approximately 11.1 W of heat is generated: 100 / 0.90 − 100. However, determine the efficiency of the chosen product for the actual load. Free space above the device does not replace verification of airflow in the enclosure.

Input inrush current and protection

AC inrush is a short input current when charging capacitors after connection to the mains. It is not the same as the starting current of a load on the DC output. The cause and methods of limiting it are described in the PULS documentation on inrush current. When several power supplies are switched on together, check the entire feed, the switching element and the manufacturer's recommendations. The ratio of output watts to mains voltage alone is not enough to choose a circuit breaker.

On the output, coordinate the protection of the individual branches with the current limiting of the power supply and the resistance of the wiring. The power supply may limit the current before an ordinary circuit breaker trips quickly; this relationship is discussed in PULS: protection of DC circuits. The specific solution must suit the cabling, load and required selectivity. The internal protection of the power supply does not automatically replace the protection of every branch.

SELV and PELV are not designations of 24 V

Both extra-low-voltage protective systems require appropriate protective separation from higher-voltage circuits. SELV maintains separation from earth; PELV allows earthing according to the protection design. The difference is explained in Schneider Electric documentation on SELV and the relationship between SELV and PELV. Connecting the protective conductor to the chassis of the power supply is not the same as connecting the negative output to earth.

Assess suitability for the whole circuit, including connections to other devices. 24 V alone, a plastic housing or the general brand of the manufacturer do not prove SELV or PELV. The equipment requirements, specific documents and earthing method must match.

Voltage at the load and verification procedure

Also check the voltage at the load at maximum consumption. As a model, a total loop resistance of 0.4 Ω at 1.5 A creates a drop of 0.6 V. By increasing the supply voltage you may overload nearby devices; first assess the conductors, length and distribution of branches.

  1. Verify the input network, number of phases, output voltage and polarity.
  2. Compare the current balance with the permissible load after derating and with the start-up.
  3. Check the mounting, terminals, protective connection and coordination of protection.
  4. During commissioning, verify start-up of the whole assembly, the voltage at the load and behaviour after a power failure. Mains wiring and interventions are carried out by a qualified person according to the documentation, de-energised and after securing the workplace.

FAQ

Can I connect two outputs and get double the current?

Only with parallel operation permitted by the manufacturer and meeting its conditions. Redundancy also requires capacity for the fault state and suitable separation of branches; the difference is described in PULS: parallel operation and redundancy. Two power supplies loaded together to the maximum do not provide backup if one fails.

Will a more powerful power supply solve every PLC restart?

No. First separate insufficient power from voltage drop on the wiring, overload of one branch, interference or an intermittent contact. Record during which event the problem occurs; replacement without this distinction may leave the real cause untouched.

Cookies on this website