BAE0118, BALLUFF, power supply 24VDC/40A, 960W, 3f, DIN rail
BAE0118 BALLUFF is an industrial power supply 24VDC/40A with a power of 960W. Version: IP20, DIN rail. Suitable for industrial automation, machines and control cabinets.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Power supplies for automation, control cabinets and machines – 5, 12, 24 and 48 V DC switched-mode supplies for DIN rail and panel mounting from MEAN WELL, Siemens, Omron, Balluff, IDEC and others. Choose by output voltage and current with reserve, supply network, dimensions and operating temperature.
BAE0118 BALLUFF is an industrial power supply 24VDC/40A with a power of 960W. Version: IP20, DIN rail. Suitable for industrial automation, machines and control cabinets.
BAE0118 BALLUFF is an industrial power supply 24VDC/40A with a power of 960W. Version: IP20, DIN rail. Suitable for industrial automation, machines and control cabinets.
6EP3434-7SC00-3AX0 Siemens SITOP PSU6200 is a regulated power supply with an output of 24 V DC / 10 A and a version for three-phase AC input. Designed for automation control cabinets, PLCs…
6EP1333-7CA10 Siemens SITOP PSU100P is a regulated power supply with an output of 24 V DC / 5 A and a version for single-phase AC input. Designed for installations directly at the machine outside a…
BAE00FL BALLUFF is an industrial power supply 24VDC/8A with a power of 192W. Version: IP67, flange mounting. Suitable for industrial automation, machines and control cabinets.
BAE00FY BALLUFF is an industrial power supply 24VDC/8A with a power of 192W. Version: IP67, flange mounting. Suitable for industrial automation, machines and control cabinets.
BAE00ET BALLUFF is an industrial power supply 24VDC/8A with a power of 192W. Version: IP67, flange mounting. Suitable for industrial automation, machines and control cabinets.
BAE00FL BALLUFF is an industrial power supply 24VDC/8A with a power of 192W. Version: IP67, flange mounting. Suitable for industrial automation, machines and control cabinets.
BAE00FY BALLUFF is an industrial power supply 24VDC/8A with a power of 192W. Version: IP67, flange mounting. Suitable for industrial automation, machines and control cabinets.
BAE00ET BALLUFF is an industrial power supply 24VDC/8A with a power of 192W. Version: IP67, flange mounting. Suitable for industrial automation, machines and control cabinets.
6EP3436-8SB00-4AY0 Siemens SITOP PSU8400 is a regulated power supply with an output of 24 V DC / 20 A and a version for three-phase AC input. Designed for production lines, control cabinets and…
S8VK-T24024 OMRON is an industrial power supply of the S8VK-T. series with a power of 240 W, an output of 24 V DC and a rated current of 10 A. Version: Three-phase DIN power supply. Supply / phase…
S8FS-G30024CD-500 OMRON is an industrial power supply of the S8FS-G. series with a power of 300 W, an output of 24 V DC and a rated current of 14 A. Version: Built-in / DIN. Supply / phase: 1f…
BAE00TL BALLUFF is an industrial power supply 24VDC/8A with a power of 192W. Version: IO-Link, IP67, flange mounting. Suitable for industrial automation, machines and control cabinets.
BAE00TM BALLUFF is an industrial power supply 24VDC/8A with a power of 192W. Version: IO-Link, IP67, flange mounting. Suitable for industrial automation, machines and control cabinets.
BAE00TN BALLUFF is an industrial power supply 24VDC/8A with a power of 192W. Version: IO-Link, IP67, flange mounting. Suitable for industrial automation, machines and control cabinets.
BAE00TL BALLUFF is an industrial power supply 24VDC/8A with a power of 192W. Version: IO-Link, IP67, flange mounting. Suitable for industrial automation, machines and control cabinets.
BAE00TM BALLUFF is an industrial power supply 24VDC/8A with a power of 192W. Version: IO-Link, IP67, flange mounting. Suitable for industrial automation, machines and control cabinets.
BAE00TN BALLUFF is an industrial power supply 24VDC/8A with a power of 192W. Version: IO-Link, IP67, flange mounting. Suitable for industrial automation, machines and control cabinets.
SDR-960-24 Mean Well – switched-mode power supply of the SDR-960 series for DIN rail, 960W, 24VDC/40A, input 180–264VAC. Suitable for industrial control cabinets, PLCs, HMIs, sensors, relays and…
6EP1536-3AA00 Siemens SITOP PSU400M is an industrial DC/DC converter converting 600 V DC to 24 V DC / 20 A. Designed for machines and control cabinets where the available DC voltage needs to be…
6EP1437-2BA20 Siemens SITOP PSU300S is a regulated power supply with an output of 24 V DC / 40 A and a version for three-phase AC input. Designed for standard to more demanding machines and control…
S8VK-X09024A-EIP OMRON is an industrial power supply of the S8VK-X. series with a power of 90 W, an output of 24 V DC and a rated current of 3.75 A. Version: Smart / network power supply. Supply /…
S8VK-S24024 OMRON is an industrial power supply of the S8VK-S. series with a power of 240 W, an output of 24 V DC and a rated current of 10 A. Version: DIN, coated. Supply / phase: 1f. Connection…
6EP3437-8SB00-0AY0 Siemens SITOP PSU8200 is a regulated power supply with an output of 24 V DC / 40 A and a version for three-phase AC input. Designed for PLCs, HMIs, sensors, actuators and other…
Prices include the recycling fee.
Choose a power supply as part of the entire supply circuit: from the mains feed through the control cabinet to the terminals of the most distant load. The correct output voltage is the first condition, not full confirmation of compatibility. The current during normal operation and start-up, the temperature inside the enclosure, protection, mounting method and the requirements of the connected equipment for protective separation are also decisive.
The catalogue divides the range into the categories Allen-Bradley power supplies, IDEC 5/12/24V DC power supplies, CHINFA 12/24V DC power supplies, PULS 24V DC power supplies, Rievtech power supplies and Siemens power supplies. Catalogue items include, for example, CHINFA DRS1-24A and DRS5-24A, PULS PIC120.241C, Rievtech RPS-60-24 and several Siemens order codes. The parameters of these products are not common parameters of the whole category. The existence of the branch also does not confirm the availability of a specific type.
A switched-mode power supply converts input energy using a rapidly switched power circuit; feedback adjusts the operation so that the output holds the required voltage within the permitted limits. Output filtering limits ripple but does not eliminate all transients. The basic difference from a linear power supply is described in the IDEC technical FAQ. For sensitive analogue measurement, therefore check not only the rated voltage but also the ripple, permissible interference and the routing of common return conductors.
List all loads by voltage branch. For each, record the highest operating current, short-term consumption, its duration and when it occurs. Do not calculate the coil current from the current capacity of its contacts; the figure on a relay output is not the relay's consumption. For equipment with externally powered outputs, check whether the documented consumption also includes the connected loads. Do not count the same current twice.
The required continuous current is determined by the worst permissible simultaneous operation, not by the average over a shift. Compare the peak with the overload characteristic of the selected power supply, including its duration and repetition. The boost designation alone is not enough. Design the reserve according to expansion and actual operating uncertainties; a universal percentage does not replace assessment of the start-up.
Consider a hypothetical 24 V branch: the controller draws 0.45 A, the panel 0.35 A, eight sensors 0.03 A each and four simultaneously energised coils 0.12 A each. The sum is 1.52 A, i.e. 36.48 W. If the panel needs 1.10 A instead of 0.35 A at switch-on for 80 ms, the simultaneous consumption rises to 2.27 A. These are chosen inputs for the example, not data of the devices offered.
A power supply with a rated current of 2 A cannot be approved from the first sum alone, nor automatically rejected from the second: the permissible time characteristic and the voltage drop will decide. If we do not know it, we do not assume a short-term reserve. Delaying some loads can only help if their sequence is also ensured after the power supply is restored.
Derating means reducing the permissible load under specified conditions. It may relate to ambient temperature, altitude or a different mounting position; the curve of the specific type is decisive, as explained in the PULS guide to derating. The upper operating temperature is not automatically the temperature for full power. Assess the air at the power supply, not just the room temperature.
Your own design check should include the width on the rail, the depth including terminals, conductor bending and the prescribed ventilation clearances. Losses also belong in the heat balance. As a model, with an output of 100 W and an assumed efficiency of 90 %, approximately 11.1 W of heat is generated: 100 / 0.90 − 100. However, determine the efficiency of the chosen product for the actual load. Free space above the device does not replace verification of airflow in the enclosure.
AC inrush is a short input current when charging capacitors after connection to the mains. It is not the same as the starting current of a load on the DC output. The cause and methods of limiting it are described in the PULS documentation on inrush current. When several power supplies are switched on together, check the entire feed, the switching element and the manufacturer's recommendations. The ratio of output watts to mains voltage alone is not enough to choose a circuit breaker.
On the output, coordinate the protection of the individual branches with the current limiting of the power supply and the resistance of the wiring. The power supply may limit the current before an ordinary circuit breaker trips quickly; this relationship is discussed in PULS: protection of DC circuits. The specific solution must suit the cabling, load and required selectivity. The internal protection of the power supply does not automatically replace the protection of every branch.
Both extra-low-voltage protective systems require appropriate protective separation from higher-voltage circuits. SELV maintains separation from earth; PELV allows earthing according to the protection design. The difference is explained in Schneider Electric documentation on SELV and the relationship between SELV and PELV. Connecting the protective conductor to the chassis of the power supply is not the same as connecting the negative output to earth.
Assess suitability for the whole circuit, including connections to other devices. 24 V alone, a plastic housing or the general brand of the manufacturer do not prove SELV or PELV. The equipment requirements, specific documents and earthing method must match.
Also check the voltage at the load at maximum consumption. As a model, a total loop resistance of 0.4 Ω at 1.5 A creates a drop of 0.6 V. By increasing the supply voltage you may overload nearby devices; first assess the conductors, length and distribution of branches.
Only with parallel operation permitted by the manufacturer and meeting its conditions. Redundancy also requires capacity for the fault state and suitable separation of branches; the difference is described in PULS: parallel operation and redundancy. Two power supplies loaded together to the maximum do not provide backup if one fails.
No. First separate insufficient power from voltage drop on the wiring, overload of one branch, interference or an intermittent contact. Record during which event the problem occurs; replacement without this distinction may leave the real cause untouched.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.