EBM24GD24, EMAS, surface-mounted empty housing 24p, double side entry, 4 levers
EMAS EBM24GD24: surface-mounted empty housing, 24p, double side entry, with four levers. EBM industrial series.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
24-pin EMAS EBM industrial metal connectors for cable harnesses of machines and control cabinets. The range includes plugs, sockets, contact inserts, empty housings and protective covers. Choose the direction of the cable entry and the mechanical design of both halves.
EMAS EBM24GD24: surface-mounted empty housing, 24p, double side entry, with four levers. EBM industrial series.
EMAS EBM24GD27: surface-mounted empty housing, 24p, double side entry, with two metal levers. EBM industrial series.
EMAS EBM24PU1T: portable socket, 24p, side entry, 16A, prepared for one metal lever. EBM industrial series.
EMAS EBM24PU3T: portable socket, 24p, top entry, 16A, prepared for one metal lever. EBM industrial series.
EMAS EBM24FM41: machine-mounted plug, 24p, bottom entry, 16A, with one lever. EBM industrial series.
EMAS EBM24FM47: machine-mounted plug, 24p, bottom entry, 16A, with two metal levers. EBM industrial series.
EMAS EBM24PM41: machine-mounted socket, 24p, bottom entry, 16A, with one lever. EBM industrial series.
EMAS EBM24PM47: machine-mounted socket, 24p, bottom entry, 16A, with two metal levers. EBM industrial series.
EMAS EBM24PM4K: portable socket, 24p, bottom entry, 16A, with one metal lever. EBM industrial series.
EMAS EBM24PU14: portable socket, 24p, side entry, 16A, with four levers. EBM industrial series.
EMAS EBM24PU17: portable socket, 24p, side entry, 16A, with two metal levers. EBM industrial series.
EMAS EBM24FD17: surface-mounted plug, 24p, side entry, 16A, with two metal levers. EBM industrial series.
EMAS EBM24PD17: surface-mounted socket, 24p, side entry, 16A, with two metal levers. EBM industrial series.
EMAS EBM24PD27: surface-mounted socket, 24p, double side entry, 16A, with two metal levers. EBM industrial series.
Prices include the recycling fee.
24-pin EMAS EBM industrial metal connectors for cable harnesses of machines and control cabinets. The range includes plugs, sockets, contact inserts, empty housings and protective covers. Choose the direction of the cable entry and the mechanical design of both halves.
The range includes, for example, EBM24FU10, EBM24FU30, EBM24PU10, EBM24PM44, inserts EBM24CF00 and EBM24CP00 as well as cover EBA24TK. For cable variants FU10 and FU30, EMAS distinguishes side and top entry. Therefore choose the housing according to the actual route of the harness and operator access.
The same size may differ in fixing method, locking and the parts supplied. Before ordering, compare both halves of the connection as a whole. Record separately the items that are already part of the product and the items ordered additionally. This will avoid an assembly with two identical inserts and a missing counterpart.
Practical documentation should link the electrical diagram with the physical conductor list. For each circuit, state its function, source, return path and designation at both ends. The supply branch, diagnostic signal and spare should be distinguishable even when the disconnected harness is checked on its own.
A free position alone is not proof that any circuit can be added to it. Before expanding, check the requirements for separation, joint routing and the operating environment. For example, adding a new signal may also require a return conductor or a different cable version. The number of positions needed therefore does not necessarily grow by one.
Place the conductor markings so that they do not disappear inside an inaccessible place after mounting. Add a view of the mating face and the housing identification to the connector table. When checking, follow each connection from the source terminal to its actual destination, not just the conductor colour at the connector.
After a modification, record the new wiring in a single valid revision of the documentation. Clearly distinguish old variants so that an earlier harness with the same outer appearance is not used during a service replacement. Professional installation must also include mechanical locking and safely disconnected equipment. Broader orientation is offered by the guide to industrial connectors.
No. One device may need several conductors and a common connection must be explicitly designed.
Mark the spares and describe their state. The chosen termination method must correspond to a safe harness design.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.