EBA16TK, EMAS, protective cover for socket 16pin
EBA16TK – EMAS protective cover for 16-pin industrial connectors. Separate accessory without contacts. Verify the housing size and fixing method.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
16-pin EMAS EBM metal connectors for connecting multi-pole cable harnesses. Choose a cable or fixed version, a contact insert, an empty housing or a protective cover. Verify the number of poles for the specific item: the category also contains some 6-pole inserts.
EBA16TK – EMAS protective cover for 16-pin industrial connectors. Separate accessory without contacts. Verify the housing size and fixing method.
EBM16GM44, EMAS – panel empty housing for EBM industrial multi-pole connector, 16 poles, 16A, bottom entry, PG21, IP65. Metal powder-coated version, operating temperature -40 to +125°C. It is an…
EBM16CF00 – 16-pole EMAS contact insert, male version, 16 A. Separate electrical part of an industrial connector. Choose the matching housing and counterpart.
EBM16CP00 – 16-pole EMAS contact insert, female version, 16 A. Separate electrical part of an industrial connector. Choose the matching housing and counterpart.
EBM16FU30 – 16-pin EMAS EBM metal industrial connector, male version, 16 A, top entry. Connector with a contact insert for detachable connection of cables and equipment.
EBM16FU10 – 16-pin EMAS EBM metal industrial connector, male version, 16 A, side entry. Connector with a contact insert for detachable connection of cables and equipment.
EBM16PM44 – 16-pin EMAS EBM metal industrial connector, female version, 16 A, bottom entry. Connector with a contact insert for detachable connection of cables and equipment.
EBM16PD24 – 16-pin EMAS EBM metal industrial connector, female version, 16 A, double side entry. Connector with a contact insert for detachable connection of cables and equipment.
EBM16PU34 – 16-pin EMAS EBM metal industrial connector, female version, 16 A, top entry. Connector with a contact insert for detachable connection of cables and equipment.
EBM16PD14 – 16-pin EMAS EBM metal industrial connector, female version, 16 A, side entry. Connector with a contact insert for detachable connection of cables and equipment.
EBM16GU10, EMAS – cable empty housing for EBM industrial multi-pole connector, 16 poles, 16A, side entry, PG21, IP65. Metal powder-coated version, operating temperature -40 to +125°C. It is an empty…
EBM16GU30, EMAS – cable empty housing for EBM industrial multi-pole connector, 16 poles, 16A, top entry, PG21, IP65. Metal powder-coated version, operating temperature -40 to +125°C. It is an empty…
EMAS EBM16GU1T: portable empty housing, 16p, side entry, prepared for one metal lever. EBM industrial series.
EMAS EBM16GM47: machine-mounted empty housing, 16p, bottom entry, with two metal levers. EBM industrial series.
EBM16GU34, EMAS – cable empty housing for EBM industrial multi-pole connector, 16 poles, 16A, top entry, PG21, IP65. Metal powder-coated version, operating temperature -40 to +125°C. It is an empty…
EMAS EBM16GU14: portable empty housing, 16p, side entry, with four levers. EBM industrial series.
EMAS EBM16GU37: portable empty housing, 16p, top entry, with two metal levers. EBM industrial series.
EMAS EBM16FU10-PG29: portable plug, 16p, side entry, 16A. EBM industrial series.
EMAS EBM16FU1T: portable plug, 16p, side entry, 16A, prepared for one metal lever. EBM industrial series.
EMAS EBM16FU3T: portable plug, 16p, top entry, 16A, prepared for one metal lever. EBM industrial series.
EMAS EBM16PU1T: portable socket, 16p, side entry, 16A, prepared for one metal lever. EBM industrial series.
EMAS EBM16PU3T: portable socket, 16p, top entry, 16A, prepared for one metal lever. EBM industrial series.
EMAS EBM16GD27: surface-mounted empty housing, 16p, double side entry, with two metal levers. EBM industrial series.
EMAS EBM16GD17: surface-mounted empty housing, 16p, side entry, with two metal levers. EBM industrial series.
EBM16GD14, EMAS – surface-mount empty housing for EBM industrial multi-pole connector, 16 poles, 16A, side entry, PG21, IP65. Metal powder-coated version, operating temperature -40 to +125°C. It is…
Prices include the recycling fee.
16-pin EMAS EBM metal connectors for connecting multi-pole cable harnesses. Choose a cable or fixed version, a contact insert, an empty housing or a protective cover. Verify the number of poles for the specific item: the category also contains some 6-pole inserts.
Besides EBM16CF00 and EBM16CP00 the range includes, for example, EBM16FU10, EBM16FU30, EBM16PM44, EBA16TK and LAPP EPIC H-BE 16SSDR. The EMAS manufacturer overview distinguishes cable and fixed versions. Therefore do not consider the insert code as an automatic order for both halves of the complete connection.
There are also EB0606CF00 and EB0606CP00. The manufacturer designates EB0606CF00 as a six-pole insert. Its inclusion in this category does not make it a sixteen-pole version. The selection must be based on the exact code and drawing, not just on the group heading.
For each loaded branch, note the current during normal operation, any inrush and its duration. Then describe the combinations that can occur at the same time. An interface of sequentially activated functions looks different from an assembly in which all loads run permanently. A single figure for the total power consumption of the machine does not replace this information.
HARTING explains derating as the dependence of the permissible current on temperature. When assessing a specific connector, therefore look for its own load conditions and the conductors used. A third-party curve helps to understand the principle, not as an approval of a product of another series.
Design the internal core lengths so that the insert can be fitted without forcibly folding the conductors. Check the prescribed cross-section, termination and mounting procedure for each terminal. There is no universal tightening torque for all inserts. The number of conductors also does not determine the outer diameter of the cable, by which you select the gland.
In the test report, distinguish between checking the wiring and verifying the behaviour of the equipment. Correct continuity of one core does not yet confirm that the operator will see the correct signal. Record changes made during replacement in the same revision of the diagram. Other sizes can be found in the category Industrial connectors.
No. The range also includes parts with a different function or number of contacts; verify the order code of each component.
Not without explicit approval of such a design. The current distribution may not be even, and the number of free positions alone guarantees nothing.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.