Phone +420 774 723 123 Cart · 0 · empty

16-Pin Metal Connectors

16-pin EMAS EBM metal connectors for connecting multi-pole cable harnesses. Choose a cable or fixed version, a contact insert, an empty housing or a protective cover. Verify the number of poles for the specific item: the category also contains some 6-pole inserts.

Filters
Found 43 products
OUR TIP

EBM16PU10, EMAS, industrial plug, 16, 16A

Cat. no.: EBM16PU10

EBM16PU10 – 16-pin EMAS EBM metal industrial connector, female version, 16 A, side entry. Connector with a contact insert for detachable connection of cables and equipment.

On request
14,77 €
excl. VAT · 17,87 € incl. VAT
OUR TIP

EBM16PU30, EMAS, industrial plug, 16, 16A

Cat. no.: EBM16PU30

EBM16PU30 – 16-pin EMAS EBM metal industrial connector, female version, 16 A, top entry. Connector with a contact insert for detachable connection of cables and equipment.

On request
15,88 €
excl. VAT · 19,21 € incl. VAT
OUR TIP

EBM16FM44, EMAS, industrial socket, 16, 16A

Cat. no.: EBM16FM44

EBM16FM44 – 16-pin EMAS EBM metal industrial connector, male version, 16 A, bottom entry. Connector with a contact insert for detachable connection of cables and equipment.

On request
16,71 €
excl. VAT · 20,21 € incl. VAT

EBM16PU14, EMAS, portable socket 16p 16A, side entry, 4 levers

Cat. no.: EBM16PU14

EMAS EBM16PU14: portable socket, 16p, side entry, 16A, with four levers. EBM industrial series.

On request
17,52 €
excl. VAT · 21,19 € incl. VAT
OUR TIP

EBM16FD14, EMAS, industrial socket, 16, 16A

Cat. no.: EBM16FD14

EBM16FD14 – 16-pin EMAS EBM metal industrial connector, male version, 16 A, side entry. Connector with a contact insert for detachable connection of cables and equipment.

On request
20,97 €
excl. VAT · 25,37 € incl. VAT
OUR TIP

EBM16FD24, EMAS, industrial socket, 16, 16A

Cat. no.: EBM16FD24

EBM16FD24 – 16-pin EMAS EBM metal industrial connector, male version, 16 A, double side entry. Connector with a contact insert for detachable connection of cables and equipment.

On request
21,34 €
excl. VAT · 25,82 € incl. VAT

Prices include the recycling fee.

16-pin EMAS EBM metal industrial connectors

16-pin EMAS EBM metal connectors for connecting multi-pole cable harnesses. Choose a cable or fixed version, a contact insert, an empty housing or a protective cover. Verify the number of poles for the specific item: the category also contains some 6-pole inserts.

What you are selecting in this category

Besides EBM16CF00 and EBM16CP00 the range includes, for example, EBM16FU10, EBM16FU30, EBM16PM44, EBA16TK and LAPP EPIC H-BE 16SSDR. The EMAS manufacturer overview distinguishes cable and fixed versions. Therefore do not consider the insert code as an automatic order for both halves of the complete connection.

There are also EB0606CF00 and EB0606CP00. The manufacturer designates EB0606CF00 as a six-pole insert. Its inclusion in this category does not make it a sixteen-pole version. The selection must be based on the exact code and drawing, not just on the group heading.

Supplement the conductor list with operating states

For each loaded branch, note the current during normal operation, any inrush and its duration. Then describe the combinations that can occur at the same time. An interface of sequentially activated functions looks different from an assembly in which all loads run permanently. A single figure for the total power consumption of the machine does not replace this information.

HARTING explains derating as the dependence of the permissible current on temperature. When assessing a specific connector, therefore look for its own load conditions and the conductors used. A third-party curve helps to understand the principle, not as an approval of a product of another series.

Accessibility and harness acceptance

Design the internal core lengths so that the insert can be fitted without forcibly folding the conductors. Check the prescribed cross-section, termination and mounting procedure for each terminal. There is no universal tightening torque for all inserts. The number of conductors also does not determine the outer diameter of the cable, by which you select the gland.

In the test report, distinguish between checking the wiring and verifying the behaviour of the equipment. Correct continuity of one core does not yet confirm that the operator will see the correct signal. Record changes made during replacement in the same revision of the diagram. Other sizes can be found in the category Industrial connectors.

FAQ

Can I go just by the 16-pin heading?

No. The range also includes parts with a different function or number of contacts; verify the order code of each component.

Can the current be increased by doubling the contacts?

Not without explicit approval of such a design. The current distribution may not be even, and the number of free positions alone guarantees nothing.