PSA080AK131S, EMAS, Main switch standard 0-1, angle 60 °, number of poles 1, current 80A
PSA080AK131S EMAS - main cam switch 0-1, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Operating on and off, loading of individual routes and assembly.
PSA080AK131S EMAS - main cam switch 0-1, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA040AK831S EMAS - main cam switch 0-1, 400V AC, 40A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA050AK231S EMAS - main cam switch 0-1, 400V AC, 50 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA063AK231S EMAS - main cam switch 0-1, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA080AK231S EMAS - main cam switch 0-1, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA050AK331S EMAS - main cam switch 0-1, 400V AC, 50 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA063AK331S EMAS - main cam switch 0-1, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA050AK831S EMAS - main cam switch 0-1, 400V AC, 50 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA063AK831S EMAS - main cam switch 0-1, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA080AK331S EMAS - main cam switch 0-1, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA080AK831S EMAS - main cam switch 0-1, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.
Prices include the recycling fee.
Splice On/Off switches at 60° for a clear switch between off and on operational states. For a two-way switch, the specification changes: do not choose A or B, but determine which electrical paths to close in position 1 and open in position 0. The required number of poles depends on the circuit, not on the number of these positions.
For example, TECHNOLINE presents EMAS PSA010AK131S, PSA016AK131S and PSA020AK131S. Manufacturer for PSA016AK131S confirms one pole path, marking 0-1, angle 60 ° and forehead 48 × 48 mm. His Ie 16 A is given in category AC21A. This model therefore represents a specific single-pole design, not a universal solution of each supply.
Before selecting, determine all paths that change state together. Current mechanical control does not mean that currents from different poles simply add up to a single allowed value. Each path has its load, and the entire device has its operational conditions. For a combination of several functions, also verify the actual contact program.
Position 0 is the operational state indicator, not proof of suitability for insulation. If the project requires a main disconnection function, handle it explicitly according to the documentation. Even transitioning to a branch On / Off Safety switches 90 ° is not an automatic solution to such a requirement without checking the parameters.
To explain the current, choose two ideal resistive loads, each with 600 W at 230 V. Each draws approximately 600/230 = 2.61 A. The total power is 1,200 W. If considering a common path carrying both loads, it draws approximately 5.22 A; a single path for one load still carries only 2.61 A. The specific circuit structure determines this.
This specific example does not determine the wiring of fuses or the recommended number of poles. It calculates an ideal steady-state load, not a possible startup event or device heating. Results cannot be transferred to a motor of the same power. For a motor, specify the starting value and usage conditions; a simple ratio of watts and volts does not create it.
When swapping, keep function 0–1 but compare the full code, usage category, voltage, and mechanical arrangement. A larger current model does not necessarily have the same depth or mounting. Add the panel part dimensions and access to connection points with a diagram.
For separate installation choose the corresponding box and other accessoriesThe enclosure of the entire assembly depends on the installation of the controller and cable inputs. For a switch, compare the marked position with the actual contact state and the machine documentation. Installing on mains voltage is not a task for trial installation based on a similar photo; it should be done by a professional.
No. Two 0 and 1 positions determine the grip states. The number of poles is a separate electrical figure.
Not always. Another load may require a different category or special switching conditions, even if it has a smaller steady-state consumption.
When the actuator has to choose between multiple functions, not just allow one. The distribution of programs and basic dimensioning rules describes the overview Vacuum cleaners.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.