PSA050KD334S, EMAS, Switch standard 1-0-2, angle 60 °, number of poles 3, current 50A
PSA050KD334S EMAS - cam switch 1-0-2, 400V AC, 50 A, IP54. Technical specifications, use, installation and selection of the correct variant.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Two central choices, the importance of position 0 and the continuity of the steering.
PSA050KD334S EMAS - cam switch 1-0-2, 400V AC, 50 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA080KD234S EMAS - cam switch 1-0-2, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA063KD334S EMAS - cam switch 1-0-2, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.
PSA080KD334S EMAS - cam switch 1-0-2, 400V AC, 80A, IP54. Technical specifications, use, installation and selection of the correct variant.
Prices include the recycling fee.
A three-position switch with the marking 1–0–2 offers two options separated by the central position. It is suitable as a default solution where the operator must explicitly select the neutral state besides two modes. The electrical meaning of the center must correspond to the contact program and the function of the entire device. Zero on the label is not itself confirmation of safe disconnection.
The offer includes EMAS PSA010KD134S, PSA016KD234S and PSA025KD434S. PSA010KD134S Manufacturer presents One pole, position 1-0-2, angle 60 °, forehead 48 × 48 mm and Ie 10 A in AC21A. The device has three marked positions, yet it is not three-pole. The required number of switched paths is therefore determined separately.
Compared to two-position switches 60 ° The main difference is the available central option, not automatically higher load capacity. Even the number of visible contacts cannot be simply converted to the number of poles without a diagram. The contact program may include bindings that are not visible on the front side.
Describe which paths in the center are interrupted and which functions should remain available. For the process mode 'off', for example, signalization or diagnostics may remain active. This is not the same as disconnecting the input for maintenance. If the switch has to handle disconnection, you need a specifically specified applicability of the concrete device and the design of the corresponding circuit.
Besides the fixed positions, check the passage through the center. The assignment must determine whether a conflict of commands can occur when switching from 1 to 2 and how it might be evaluated. The actual contact closure, the moment of disconnection and engagement, and any auxiliary paths are determined by the production diagram. The angle on the label does not replace the time sequence.
Consider your own logical panel assignment. Position 1 requires the local mode, the center interrupts both mode requests, and position 2 asks for automation. The table of required signals M/A has therefore the states 1/0, 0/0, and 0/1. The combination 1/1 is not permissible. This is not the actual contact table PSA010KD134S; it is the basis on which the designer selects the appropriate program.
We will then select the request so that the input to the automation does not automatically start the movement. The mode selection differs from the command to start. When crossing zero, the control must unequivocally determine whether the unfinished request is being cancelled and whether new confirmation is necessary. A mechanical switch cannot resolve this follow-up logic without the design of other parts.
For each looped path, determine the type of load and working conditions. Two circuits controlled by one handle do not necessarily have to have the same voltage or contact resistance; the suitability of such use must be determined. The current from the catalog name is not a universal motor value. For control inputs, also consider the actual small looped current.
On the panel, the center must be clearly identifiable and the marking must agree with the mechanism setting. Check the mounting dimensions and cable space both before and after closing the doors. Comparing multiple options offers a branch. step cam switches; general selection procedure Vacuum cleanersElectrical installation is performed by a competent person.
No. Revision requires appropriate program and motor switching parameters. A similar label does not demonstrate such function.
Only if this function explicitly meets the specific performance and is correctly incorporated into the device. Normal cancellation of command is not proof of a hopeless state.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.