Two-position switches 60 °

Two stable options, a contact transition and a selection of execution without a middle zero.

Filters
Found 27 products
OUR TIP

PSA063KD333S, EMAS, switch standard 1-2, angle 60 °, number of poles 3, current 63A

Cat. no.: PSA063KD333S

PSA063KD333S EMAS - cam switch 1-2, 400V AC, 63 A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
39,01 €
excl. VAT · 47,21 € incl. VAT
OUR TIP

PSA080KD333S, EMAS, switch standard 1-2, angle 60 °, number of poles 3, current 80A

Cat. no.: PSA080KD333S

PSA080KD333S EMAS - cam switch 1-2, 400V AC, 80 A, IP54. Technical specifications, use, installation and selection of the correct variant.

On request
40,96 €
excl. VAT · 49,56 € incl. VAT

Prices include the recycling fee.

Two-position switches 60 °

A two-position cam switch is a good starting point for selecting between two modes if a central position is not required. The notation 1–2 describes the controller, not the entire electrical system automatically. When selecting, it is crucial whether the signal, control circuit, or load is being switched, and what can happen during the movement of the handle.

Specific example from the offer

TECHNOLINE presents EMAS PSA010KD133S. The manufacturer shall specify for this model: one pole path, position 1-2, angle 60 °, forehead 48 × 48 mm and current Ie 10 A in category AC21A. One pole and two positions are different properties; the number two is not the number of phases. The current figure refers to the declared use, not all possible loads.

First determine the transition between modes

In the specification, write not only 'local/remote' or 'branch A/B', but also the request for change. It should be short and inactive on both sides, or such an interruption is undesirable? Is the current activation disabled? The answer is then compared with the contact diagram of the specific order code. Two stable positions alone do not prove whether contacts are crossing with interruption or overlap.

A missing central zero does not replace the stop of the handle between turned-off positions. Such a state is not a designed operational mode. If the handling needs to independently select 'off', compare the specification with Three-position switches 60 °Transition behaviour and the importance of off status are also verified for them.

Model example of two commands

Consider only logical specifications for a test panel: position 1 requires mode A and position 2 requires mode B. In the first state, the pair of commands A/B should be equal to 1/0, in the second 0/1. The prohibition of the combination 1/1 is another condition that cannot be read from the number of positions alone. This example is not a real PSA010KD133S schematic or a wiring guide for specific screws.

If control records 0/0 during transition, this state must have a predefined meaning. It can be evaluated as a transitional state, but it must not be used to dismiss a real fault without assessment. The duration of such a state depends on the control design and tests, not on a 60° angle. The number of degrees does not determine the switching time in milliseconds.

Electrical and mechanical compatibility

For replacement, compare the voltage, type of load, current, and required usage category. With the data 10 A, do not calculate the permissible motor power. For low signals, however, verify the contact quality for the actual minimum current. Higher maximum current alone is not proof of reliable switching of sensitive inputs.

The face size does not provide information about the required depth. Check the panel thickness, cut-out, orientation of positions and space behind the actuator. Equipment for cam switches according to the full design, not only the commercial name. Network circuits are designed and involved by the competent person according to the production documentation.

Frequently asked questions

Is the switch 1-2 simultaneously a switch?

It does not have a declared separate 0 position with this symbol. If you require shutdown as a normal control state, specify it separately.

Is it enough to maintain the position of the handle when changing?

No. Determines the conformity of the electrical function in each position and in the transition. Basic resolution of poles, positions and loads summarizes the overview Cam switches.