PR-18DC-DA-R, Rievtech, programmable relay, 12–24VDC, 12 DI (6 AI 0–10V), 6 relay 10A, RS232/RS485
PR-18DC-DA-R Rievtech – 12–24VDC, 12 DI (6 AI 0–10V), 6 relay 10A, RS232/RS485.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Programmable relays (smart relays, logic modules) Siemens LOGO! and Rievtech for controlling smaller machines, cabinets and buildings. Choose by supply, number of inputs and outputs, expansion options, display and communication.
PR-18DC-DA-R Rievtech – 12–24VDC, 12 DI (6 AI 0–10V), 6 relay 10A, RS232/RS485.
6EP3336-3SB00-0AX0 Siemens SITOP PSU100S – 24 V DC / 20 A. Parameters, Siemens documentation and technical support.
SR-22AC-R-B Rievtech – 110–240VAC, 14 DI, 8 relay, Ethernet/RS485, without LCD.
SR-22DC-DA-R-B Rievtech – 14 DI (6 AI), 8 relay, Ethernet/RS485, without LCD.
PR-E-AC-16DO Rievtech – 110–240VAC, 16 relay (15×3A + 1×10A), without inputs.
6EP3334-7SB00-3AX0 Siemens SITOP PSU6200 – 24 V DC / 10 A. Parameters, Siemens documentation and technical support.
PR-18DC-DAI-TN-N Rievtech – 12 DI (8 analogue), 6 PNP 0.3A, Ethernet/RS485, MQTT.
PR-12AC-R-N Rievtech – 110–240VAC, 8 DI, 4 relay, Ethernet/RS485, MQTT.
SET-LOGO9-START-NODISPLAY Siemens – Siemens LOGO! starter kit 9 without display with control module, LOGO!Power supply and LOGO! Soft Comfort software V9. Contents: 6ED1052-2.
PR-18DC Starter Kit Rievtech – PR-18DC-DA-R + USB cable, 12–24VDC, 12 DI, 6 relay.
PR-18AC Starter Kit Rievtech – PR-18AC-R + USB cable, 110–240VAC, 12 DI, 6 relay.
6AG1055-1CB00-7BA2 Siemens SIPLUS LOGO! DM8 24 – 4 DI, 4 DO. SIPLUS LOGO! 8 (0BA2). -40 … +70 °C. Parameters, Siemens documentation and technical support.
6AG1055-1FB00-7BA2 Siemens SIPLUS LOGO! DM8 230R – 4 DI, 4 relay DO. SIPLUS LOGO! 8 (0BA2). -40 … +70 °C. Parameters, Siemens documentation and technical support.
6AG1055-1HB00-7BA2 Siemens SIPLUS LOGO! DM8 24R – 4 DI, 4 DO. SIPLUS LOGO! 8 (0BA2). -40 … +70 °C. Parameters, Siemens documentation and technical support.
6AG1055-1MB00-7BA2 Siemens SIPLUS LOGO! DM8 12/24R – 4 DI, 4 DO. SIPLUS LOGO! 8 (0BA2). -40 … +70 °C. Parameters, Siemens documentation and technical support.
6AG1331-6SB00-7AY0, Siemens – SIPLUS LOGO!Power power supply. Input: 100–240 V AC; Output: 24 V DC; Output current: 1.3 A; Temperature range: -40 to +70 °C; Product series: SIPLUS LOGO!Power.
SET-LOGO9-START Siemens – Siemens LOGO! starter kit 9 with control module, LOGO!Power supply and LOGO! Soft Comfort software V9. Contents: 6ED1052-1MD08-0BA3, 6EP3331-6SB0.
6EP3336-7SB00-3AX0 Siemens SITOP PSU6200 – 24 V DC / 20 A. Parameters, Siemens documentation and technical support.
6AG1055-1MD00-7BA2 Siemens SIPLUS LOGO! AM2 RTD – 2 AI for PT100 / PT1000. SIPLUS LOGO! 8 (0BA2). -40 … +70 °C. Parameters, Siemens documentation and technical support.
6AG1333-6SB00-7AY0 Siemens SIPLUS LOGO!Power 24 V / 4 A. SIPLUS LOGO!Power. -40 … +70 °C. Parameters, Siemens documentation and technical support.
Rievtech kit – SR-22DC-DA-R + 4 DI/AI + 4 relay expansion + RS485 module.
PR-26DC-DAI-RT-N Rievtech – 16 inputs, 2 PNP, 4×5A+4×10A relay, Ethernet, 2×RS485.
SET-LOGO9-EXTENDED Siemens – Siemens LOGO! extended kit 9 with control module, expansion module, LOGO!Power supply and LOGO! Soft Comfort software V9. Contents: 6ED1052-.
6AG1055-1MA00-7BA2 Siemens SIPLUS LOGO! AM2 – 2 AI. SIPLUS LOGO! 8 (0BA2). -40 … +70 °C. Parameters, Siemens documentation and technical support.
PR-26DC-DAI-R-N Rievtech – 16 inputs (12 usable as analogue), 10 relay, Ethernet/2×RS485, MQTT.
Prices include the recycling fee.
The entire tutorial is available free of charge directly on this page.
Product price: 10 CZK
The entire tutorial is publicly available free of charge directly on this page. Purchase is not a condition of access to the content. By a symbolic purchase for 10 CZK you can support the creation of further practical guides and technical materials from TECHNOLINE.
This tutorial is intended for TECHNOLINE customers who are starting with Siemens LOGO! 9 or want to quickly understand its practical use. The content is designed to be useful for people, easy to read for search engines and easy to cite for AI systems.
Safety notice: Work on electrical equipment must comply with applicable regulations and may only be carried out by a suitably qualified person. Always verify training examples in simulation first. Always verify specific wiring according to the documentation of the LOGO! 9, module used, the power supply and the connected devices.
Siemens LOGO! 9 is a compact logic module for small and standalone automation tasks. It is used, for example, for controlling lighting, ventilation, pumps, gates, smaller machines, process units and building automation functions.
LOGO! 9 is programmed in LOGO! Soft Comfort V9. The environment allows you to create control logic, simulate the project, prepare web visualisation and then transfer the project to the device.
LOGO! 9 supports up to 800 function blocks. Depending on the configuration, the system can be expanded up to 64 digital inputs, 60 digital outputs, 16 analogue inputs and 16 analogue outputs. Ethernet communication, Modbus TCP/IP, Modbus RTU and MQTT are supported.
After completing the programme you will be able to:
Any simple automation can be described as:
inputs → program logic → outputs
An input can be a push button, limit switch, thermostat, level sensor or other signal. The program evaluates the conditions and controls the output according to the result, for example a contactor, relay, signalling or other actuator.
Create the simplest task in which a digital input controls a digital output. In the simulation, change the state of the input and observe the state of the output.
Recommendation: always verify the behaviour in simulation before transferring the program to the real device.
The output is active only when all required conditions are met.
Example: the fan may only start when the equipment is enabled and at the same time there is a demand for ventilation.
The output is active if at least one of the conditions is met.
Example: the warning light is activated by an alarm from sensor A or from sensor B.
The function inverts the logic state.
Create Q1, which switches on only when I1 and I2. are activated at the same time
In many applications, a direct connection of input to output is not enough. The state needs to be remembered.
Example:
After pressing START, the operating state is activated and remains active. STOP cancels it.
Create START/STOP logic and also test the state when both commands are active at the same time. The design must clearly define the priority.
Time functions are among the most frequently used LOGO! functions.
The output is activated only after the set time.
Use: delayed fan start, sequential start of equipment or filtering of a short request.
After the condition ceases, the output remains active for a certain time.
Use: fan run-on, after-cooling or lighting run-on.
When triggered, a time-limited signal is generated.
After activation of I1 switch on Q1 with a delay of 5 seconds.
A counter processes individual events or pulses.
Typical use:
Count rising edges on I1. After 10 pulses have been reached, activate Q1. Add a separate counter reset.
A time program can be used for:
Set Q1 so that it is active on working days in a defined time interval.
Add manual enable or blocking and clearly define the priority of manual and automatic mode.
An analogue signal represents a continuous quantity, for example temperature, pressure, level or another measured value.
In the design, distinguish:
In the simulation, create an analogue value, compare it with a set limit and control the output according to the result.
Without hysteresis, the output may repeatedly switch on and off around the decision limit.
Example:
Create two-point control with separate switch-on and switch-off limits.
Practical automation often uses:
Manual mode must not bypass process or protective conditions in an uncontrolled way.
Create Q1 with AUTO/MANUAL mode. The common blocking must be effective in both modes.
A well-designed program does not just show that the equipment is not running. It also lets you find out why.
Suitable diagnostic states:
Create three separate diagnostic signals explaining why Q1 cannot be active.
LOGO! 9 offers local visualisation and can be supplemented by LOGO! TDE. LOGO! Soft Comfort V9 also integrates work with the LOGO! Web Editor.
Good visualisation should answer:
Prepare a screen with the state of Q1, the active mode, one process value and one adjustable parameter.
LOGO! 9 uses Ethernet for network communication and supports web monitoring.
When connecting to a network:
LOGO! 9 offers Secure Boot, encrypted communication and UMAC user management with four roles. However, these functions do not replace correct design of the entire network architecture.
Modbus TCP/IP is used to exchange process data between compatible systems over Ethernet.
During integration, document:
Design a data list for transferring the equipment state, one command and one analogue value between two systems.
MQTT uses the publisher/subscriber principle.
Basic terms:
Example topic names: technologie/linka1/stav technologie/linka1/teplota
In a production environment, address authentication, permissions, encryption and behaviour during a communication failure.
Test every project at least in these states:
| Test | Input state | Expected result |
|---|---|---|
| T01 | START, no interlock | Q1 active |
| T02 | STOP | Q1 inactive |
| T03 | Interlock | Q1 must not be active |
| T04 | Value at the decision limit | behaviour according to the defined hysteresis |
Requirements:
Procedure:
The fan works in automatic mode according to temperature.
Add:
Requirements:
For a real pumping system, add suitable protections, feedback and safe behaviour in case of failure.
Before you start programming, create:
This gives you a program that is easier to simulate, document and service.
First define the required behaviour and only then assemble the blocks.
For each conflicting state, it must be clearly defined which command takes precedence.
A manual command should not automatically mean bypassing all protective conditions.
An analogue value around a single limit can cause unwanted cycling.
The operator needs to know not only that the equipment is not running, but also why.
Also simulate limit and fault states.
Siemens LOGO! 9 is a compact logic module for small and standalone automation tasks in machines, switchboards and buildings.
LOGO! Soft Comfort V9 or newer is intended for LOGO! 9.
Yes. LOGO! Soft Comfort V9 includes simulation, so the logic can be verified before transfer to the device.
Up to 800 function blocks.
Siemens states up to 64 DI, 60 DQ, 16 AI and 16 AQ per LOGO! 9. system
Yes.
Yes.
Yes. LOGO! 9 supports web monitoring and LOGO! Soft Comfort V9 integrates the LOGO! Web Editor.
Yes, especially for smaller and clearly defined automation tasks. For beginners we recommend simulation first.
For larger PLC architectures, PROFINET IO, fail-safe applications, motion control or projects based on TIA Portal, the SIMATIC series is usually more suitable.
For the first practical projects, choose in particular:
Below you will find compatible related products with real order codes from the current TECHNOLINE catalogue.
The current selection of suitable products can be found in the related products for this course. Prices and stock availability are always shown directly from the TECHNOLINE catalogue.
Recommended groups:
Also use the TECHNOLINE guide to selecting Siemens LOGO! components.
This practical part takes you from the LOGO! 9 program to the design of the complete assembly. It shows how a functional control assembly is put together from the current TECHNOLINE range.
Procedure: choose the supply system and control voltage; number of DI/DQ/AI/AQ; basic module and expansions; add up the consumption of the PLC, modules, sensors, relays, TDE and other DC loads; design a power supply with reserve; determine protections; decide on interface relays/contactors; select sensors, controls, terminals, wires and enclosure; create a bill of materials.
In the design, create a table of the consumption of individual components. Verify the values in the catalogue parameters and datasheets. Do not estimate a missing value; mark it as "to be verified". After adding up the operating consumption, take into account the design reserve and peak consumption. Then select a suitable power supply from the current TECHNOLINE range, for example Siemens LOGO!Power, if it is suitable for the assembly.
A specific circuit breaker cannot be determined just by the PLC. The design depends on the voltage and system, conductors, installation method, nature of the load, short-circuit conditions, breaking capacity, selectivity and other conditions. The configurator can show suitable categories and candidate products, but marks them "verify according to the specific project". Choose suitable circuit breakers, residual current devices, DC circuit breakers, disconnectors and motor protection from the current range according to the project parameters.
Before switching directly from LOGO!, verify the output type of the specific module, AC/DC, current, switching peaks, inductive character and switching frequency. For higher or unsuitable loads, use suitable interface relays, contactors, auxiliary contacts and motor protection from the TECHNOLINE catalogue.
When choosing, consider mechanical limit switches and inductive, optical, capacitive, magnetic, temperature or pressure sensors according to the specific task. For mechanical limit switches, the EMAS range can also be used. Always check NO/NC, PNP/NPN, supply, degree of protection, connection method and compatibility with the LOGO! input. Compatibility cannot be determined just from the category name.
For control, START/STOP/RESET buttons, AUTO/MANUAL selector switches, indicator lights, signal towers, beacons, push-button boxes and engraved labels can be used. Use emergency stop only in the context of a proper safety design; a standard LOGO! does not replace a safety control system where one is required.
Recommended functional layout: incoming supply and main switch → protections → power supply → LOGO! and expansions → relays/contactors → terminal blocks → communication. Allow a reserve for cable ducts, wire bends, service, heat losses, cooling and future expansion. Complete the switchboard with a suitable enclosure or distribution board, DIN rails, cable ducts, terminals, jumpers, glands, protective conduits, ferrules, lugs and CYA wires.
The assembly should contain LOGO! 9, 24V DC power supply, START/STOP, AUTO/MANUAL, limit switch, proximity sensor, indicator lights, interface relay, model load, terminal block, protective devices, DIN rail and duct. Assemble the specific bill of materials from the currently available TECHNOLINE products.
The basic structure is LOGO! 9 → interface or switching element → contactor → motor protection → motor. Choose the specific contactor and protection only according to the motor and network parameters. Select suitable components according to the actual motor and network parameters.
Training example: OPEN, CLOSE, open/closed end position, mutual interlocking of directions, time monitoring and signalling. For sensing positions, relevant EMAS limit switches can be used according to the parameters. Real doors, gates and machines require a separate safety assessment.
Divide the bill of materials into categories: Control; Power supply and protection; Switching; Sensors; Operation; Switchboard. Recommended BOM columns: Function | Product | MPN | Quantity | Price | In stock | Link. Always verify commercial data in the current catalogue.
When designing the assembly, determine step by step: supply, control voltage, DI/DQ/AI/AQ, sensors, number of limit switches, motors/loads, TDE, communication, enclosure protection rating, buttons and indicator lights. The result is a design of the assembly and bill of materials. Verify each item according to the specific application before ordering.
Specific circuit protection, conductor cross-sections, protection against electric shock, short-circuit withstand, selectivity, EMC, degree of protection and thermal conditions must be verified for a real installation by a qualified person according to the specific application and applicable regulations. The configurator must not present an automatic design as a standards-approved project.
This part shows the basic blocks from which a LOGO! 9. solution can be assembled. Always verify specific order numbers, prices, stock availability and links in the current TECHNOLINE catalogue. Do not use LOGO! 8 expansion modules as a substitute for LOGO! 9 – Siemens states that LOGO! 8 expansion modules are not hardware-compatible with LOGO! 9.
Each LOGO! 9 basic module has 8 inputs and 4 outputs. Selection starts with the supply voltage, output type, required I/O and the need for a local display.
Application: training, laboratory panel, small 24V DC automation tasks, push buttons and common industrial sensors.
Recommended composition:
Who it is for: the best starting assembly for practical training and most demonstration projects.
To select the power supply, add up the maximum or operating consumption of the basic module and all devices supplied from 24 V DC. Select the nearest suitable TECHNOLINE power supply with a reasonable reserve. Do not estimate a missing consumption value.
Application: switchboards and applications where operation is carried out via external visualisation, web or LOGO! TDE.
Composition:
The choice "I want a display directly on LOGO!" or "I don't need a display" determines the suitable variant of the basic module.
Application: more push buttons, limit switches, sensors, relays and controlled devices.
Composition:
LOGO! DM8 12/24R adds 4 digital inputs and 4 digital outputs. Determine the number of modules according to the required DI/DQ while respecting the system limits.
Application: temperature via a transmitter, pressure, level, flow, 0–10 V / current analogue signals and analogue control.
Composition:
LOGO! AM4 AI/AQ provides 2 analogue inputs and 2 analogue outputs. Before recommending a specific sensor, check the signal type and supply.
Application: a small machine or process unit with both digital and analogue signals.
Example composition:
Here the power supply must not be chosen according to LOGO! alone. All 24V DC components supplied from the same power supply are included in the balance.
Application: applications where the LOGO! 9 basic module for 115/240 V AC/DC is chosen.
Composition:
Important: supplying LOGO! from 230 V does not mean that all peripheral devices must be 230V. If the project uses 24V DC sensors or control circuits, add a suitable 24V DC power supply.
Application: LOGO! is inside the switchboard and the operator needs an external panel.
Composition:
Do not confuse LOGO! 9 TDE with the older TDE intended for previous generations.
Quick selection of LOGO! 9 starts with the following questions:
1. What supply do you have?
2. Do you want a display directly on LOGO!?
3. How many digital inputs do you need?
4. How many digital outputs do you need?
5. Do you need analogue inputs/outputs?
6. Do you want an external LOGO! TDE?
7. What will be supplied from the auxiliary 24V DC power supply?
The resulting design includes:
Calculate the power supply from the specific assembly, not from a fixed table.
Calculation:
I_total = I_LOGO + I_snimace + I_rele + I_indication + I_TDE + I_dalsi
Then:
I_design = I_total × reserve
State the design reserve transparently. A conservative reserve does not replace checking peak currents and datasheets.
The power supply is suitable only if:
I_design,Prefer the smallest suitable power supply with reserve and consider a higher variant for future expansion.
For each design, state:
If any component does not have a verified consumption, state a prominent warning: "The power supply cannot be definitively sized – verified consumption is missing for some components."
Basic training and starter assembly
Compact assembly without local display
Extended digital assembly
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.