Economical Elstein Ceramic Infrared Heaters - FSR

Economical Elstein FSR and T-FSR ceramic infrared heaters as an affordable replacement or the basis of a new heating field. Choose by size, power and the version with thermocouple (T-FSR) for temperature control.

Filters
Found 26 products
OUR TIP

T-FSR 1000W, ELSTEIN, ceramic infrared emitter with thermocouple, 1000 W, 245 x 60mm, type K (NiCr-Ni)

Cat. no.: T-FSR 1000W

T-FSR 1000W ELSTEIN – ceramic infrared emitter with thermocouple, 1000 W, 245 x 60mm, type K (NiCr-Ni). Key data: ELSTEIN FSR, 230 V, 750 °C. Exact technical data for selecting the ceramic infrared…

On request
105,52 €
excl. VAT · 127,67 € incl. VAT

Prices include the recycling fee.

Economical ceramic infrared emitters Elstein - FSR

When replacing an FSR emitter, start by identifying the original part and its position in the assembly. A photo of a similar body does not tell you whether you will maintain the required power and measurement. Before selecting, record the designation, voltage, size and position. After replacement, you also need to confirm the heating result on the product.

Version and actual range

The FSR data sheet describes fully cast concave ceramics. T-FSR versions contain a type K thermocouple.

The range includes FSR, FSR/2 and FSR/4 as well as their T variants. The listing also includes FSR 150 W and 650 W or FSR/2 325 W. Choose the available type from the specific item; the manufacturer's overview of standard versions is not a complete list of historical or special order variants.

For your own check of the replacement, compare the documentation of the original equipment with the data of the piece being ordered. Record any uncertainty in a single parameter as an open point. For example, the same footprint may meet the mechanical requirement, but the conformity of the entire function also depends on the electrical version and the connection to the control system.

Curvature and uniformity are not the same

According to the explanation of ELSTEIN radiation distribution the concave shape of the FSR does not create a focus. In the field, the contributions of the individual emitters overlap, so the same power of all bodies can lead to stronger heating of the centre. Therefore assess the design of the edge and centre zones separately.

In the acceptance plan, draw the check points relative to the product, not just relative to the machine frame. Otherwise, if the product position changes, the same point designation would represent a different place. For each reading, record the time from the start of heating. This gives you comparable data for deciding whether it makes sense to change the zone power, the fixture position or the whole work procedure. To distinguish the influence of the sample from a fixed position, different loadings of the same test part can be compared in a safely designed test. Record whether the deviation stays in the same place on the machine or moves with the part. Use the result as a basis for further diagnostics.

Author's model example: the average can hide a problem

Let us choose a fictitious acceptance with a requirement of 145 to 155 °C at all five check points. At the same moment of the cycle we measure 144, 148, 150, 151 and 152 °C. The average is 149 °C and the difference between maximum and minimum is 8 °C. Nevertheless, the result does not comply, because the first point is below the lower limit.

The figures are the author's and do not describe the performance of any emitter offered. For simplicity, we assume correct measurement; the actual report must include its uncertainty. When looking for a remedy, first verify the repeatability of the deviation. Always change one assessed condition and measure the whole map again. Raising all values according to a single cold spot is not in itself proof of correct adjustment.

Mounting and operating limits

The mounting instructions require professional installation and protection against moisture and mechanical damage. Data sheet M 1.2 prohibits contact of the emitter with the heated product and requires temperature control for installation in an oven or for opposing emitters.

After a service intervention, compare the record of the new cycle with the last compliant state. Record the replaced position and the code used. Electrical diagnostics are carried out by a qualified worker after safe shutdown; the production process record serves to target this check, not as a substitute for an electrical test.

FAQ

Does an economical version mean the lowest operating costs?

Such a conclusion does not follow from the name. In your own evaluation, monitor purchase, service, consumption and the number of compliant pieces under comparable conditions.

When should another series be assessed?

When requirements change, prepare a comparison with HTS and a new acceptance test. The context of the whole system is explained in the category Ceramic infrared emitters.