Phone +420 774 723 123 Cart · 0 · empty

Circuit Breakers and Residual Current Devices

Miniature circuit breakers and residual current devices for protecting electrical circuits and people. The range includes MCBs with B, C and D characteristics, DC circuit breakers, RCDs and combined RCBOs. Choose by rated current, number of poles, characteristic and breaking capacity.

Subcategories

Filters
Found 108 products
OUR TIP

1SM206C, Sigma Elektrik, two-pole circuit breaker, 6A, tripping characteristic C, 10kA, (6A/C/2f), 6 A, 10 kA

Cat. no.: 1SM206C

1SM206C Sigma Elektrik – two-pole circuit breaker, 6A, tripping characteristic C, 10kA, (6A/C/2f), 6 A, 10 kA. Key data: 1SM. Exact technical data for selecting the miniature circuit breaker type.

On request
3,28 €
excl. VAT · 3,97 € incl. VAT
−2 % OUR TIP

Ex9BN 1P C10, NOARK, miniature circuit breaker 1P, 10A, characteristic C, Icn 6kA

Cat. no.: Ex9BN 1P C10

Ex9BN 1P C10, NOARK: miniature circuit breaker 1P, 10A, characteristic C; breaking capacity Icn 6kA according to EN 60898-1.

On request
3,37 € 3,44 €
excl. VAT · 4,08 € incl. VAT
−2 % OUR TIP

Ex9BN 1P C16, NOARK, circuit breaker 1-pole, 16A, characteristic C, 6 kA, 100098, 16 A

Cat. no.: Ex9BN 1P C16

Ex9BN 1P C16 NOARK – circuit breaker 1-pole, 16A, characteristic C, 6 kA, 100098, 16 A. Key data: NOARK Ex9BN. Exact technical data for selecting the miniature circuit breaker type.

On request
3,37 € 3,44 €
excl. VAT · 4,08 € incl. VAT
OUR TIP

Ex9BN 1P B1, NOARK, miniature circuit breaker 1P, 1A, characteristic B, Icn 6kA

Cat. no.: Ex9BN 1P B1

Ex9BN 1P B1, NOARK, miniature circuit breaker 1P, 1A, characteristic B, Icn 6kA. Single-pole circuit breaker Ex9BN with characteristic B and current 1A for protecting AC circuits against overload and…

On request
3,44 €
excl. VAT · 4,17 € incl. VAT
−2 % OUR TIP

Ex9BN 1P B4, NOARK, circuit breaker 1-pole, 4A, characteristic B, 6 kA, 100003, 1P, 4 A

Cat. no.: Ex9BN 1P B4

Ex9BN 1P B4 NOARK – circuit breaker 1-pole, 4A, characteristic B, 6 kA, 100003, 1P, 4 A. Key data: NOARK Ex9BN. Exact technical data for selecting the miniature circuit breaker type.

On request
3,60 € 3,67 €
excl. VAT · 4,35 € incl. VAT
−10 % OUR TIP

EKM1-63H-1P+N-04A/B, CHANGAN, Miniature circuit breaker 1P+N, 4A, characteristic B, 10kA

Cat. no.: EKM1-63H-1P+N-04A/B

EKM1-63H-1P+N-04A/B, CHANGAN, Miniature circuit breaker 1P+N, 4A, characteristic B, 10kA. This circuit breaker of the EKM1-63H series protects the circuit against overcurrent and short circuit.

On request
3,66 € 4,06 €
excl. VAT · 4,42 € incl. VAT
OUR TIP

EKM1-63DCH-1P-01A/C, CHANGAN, DC circuit breaker 1P, 1A, characteristic C, 250VDC, 10kA

Cat. no.: EKM1-63DCH-1P-01A/C

EKM1-63DCH-1P-01A/C, CHANGAN, DC circuit breaker 1P, 1A, characteristic C, 250VDC, 10kA. DC circuit breaker EKM1-63DCH for protecting a 250VDC circuit with rated current 1A and characteristic C.

On request
3,73 €
excl. VAT · 4,51 € incl. VAT
OUR TIP

EKM1-63DCH-1P-05A/C, CHANGAN, DC circuit breaker 1P, 5A, characteristic C, 250VDC, 10kA

Cat. no.: EKM1-63DCH-1P-05A/C

EKM1-63DCH-1P-05A/C, CHANGAN, DC circuit breaker 1P, 5A, characteristic C, 250VDC, 10kA. DC circuit breaker EKM1-63DCH for protecting a 250VDC circuit with rated current 5A and characteristic C.

On request
3,73 €
excl. VAT · 4,51 € incl. VAT
OUR TIP

Ex9BN 1P C4, NOARK, circuit breaker 1-pole, 4A, characteristic C, 6 kA, 100093, 1P, 4 A

Cat. no.: Ex9BN 1P C4

Ex9BN 1P C4 NOARK – circuit breaker 1-pole, 4A, characteristic C, 6 kA, 100093, 1P, 4 A. Key data: NOARK Ex9BN. Exact technical data for selecting the miniature circuit breaker type.

On request
3,89 €
excl. VAT · 4,71 € incl. VAT
OUR TIP

Ex9BN 1P C1, NOARK, circuit breaker, 100090, 1 A, C, 6 kA

Cat. no.: Ex9BN 1P C1

Ex9BN 1P C1 NOARK – circuit breaker, 100090, 1 A, C, 6 kA. Key data: NOARK Ex9BN, 1A. Exact technical data for selecting the miniature circuit breaker type.

On request
3,93 €
excl. VAT · 4,76 € incl. VAT
−10 % OUR TIP

EKM1-63H-3P-16A/C, CHANGAN, Miniature circuit breaker 3P, 16A, characteristic C, 10kA

Cat. no.: EKM1-63H-3P-16A/C

EKM1-63H-3P-16A/C, CHANGAN, Miniature circuit breaker 3P, 16A, characteristic C, 10kA. This circuit breaker of the EKM1-63H series protects the circuit against overcurrent and short circuit.

On request
4,03 € 4,47 €
excl. VAT · 4,87 € incl. VAT
OUR TIP

EKM1-63-1P+N-04A/B, CHANGAN, Miniature circuit breaker 1P+N, 4A, characteristic B, 6kA

Cat. no.: EKM1-63-1P+N-04A/B

EKM1-63-1P+N-04A/B, CHANGAN, Miniature circuit breaker 1P+N, 4A, characteristic B, 6kA. This circuit breaker of the EKM1-63 series protects the circuit against overcurrent and short circuit.

On request
4,55 €
excl. VAT · 5,51 € incl. VAT
OUR TIP

EKM1-63-1P+N-10A/B, CHANGAN, circuit breaker 2-pole, 1P+N, 10A, characteristic B, 6kA, 2 (1P+N), 10 A

Cat. no.: EKM1-63-1P+N-10A/B

EKM1-63-1P+N-10A/B CHANGAN – circuit breaker 2-pole, 1P+N, 10A, characteristic B, 6kA, 2 (1P+N), 10 A. Key data: EKM1-OF. Exact technical data for selecting the miniature circuit breaker type.

On request
4,55 €
excl. VAT · 5,51 € incl. VAT
−2 % OUR TIP

Ex9BN 3P B16, NOARK, miniature circuit breaker 3P, 16A, characteristic B, 6kA

Cat. no.: Ex9BN 3P B16

Ex9BN 3P B16, NOARK, miniature circuit breaker 3P, 16A, characteristic B, 6kA. Miniature circuit breaker Ex9BN protects single-phase or three-phase branches according to the number of poles 3P.

On request
8,83 € 9,01 €
excl. VAT · 10,68 € incl. VAT
OUR TIP

Ex9BN 3P B10, NOARK, circuit breaker 3-pole, 10A, characteristic B, 6 kA, 100051, 3P, 10 A

Cat. no.: Ex9BN 3P B10

Ex9BN 3P B10 NOARK – circuit breaker 3-pole, 10A, characteristic B, 6 kA, 100051, 3P, 10 A. Key data: NOARK Ex9BN. Exact technical data for selecting the miniature circuit breaker type.

On request
8,85 €
excl. VAT · 10,71 € incl. VAT
−2 % OUR TIP

Ex9BN 3P B32, NOARK, circuit breaker 3-pole, 32A, characteristic B, 6 kA, 100056, 3P, 32 A

Cat. no.: Ex9BN 3P B32

Ex9BN 3P B32 NOARK – circuit breaker 3-pole, 32A, characteristic B, 6 kA, 100056, 3P, 32 A. Key data: NOARK Ex9BN. Exact technical data for selecting the miniature circuit breaker type.

On request
9,28 € 9,47 €
excl. VAT · 11,23 € incl. VAT
OUR TIP

Ex9BN 3P B6, NOARK, circuit breaker 3-pole, 6A, characteristic B, 6 kA, 100049, 3P, 6 A

Cat. no.: Ex9BN 3P B6

Ex9BN 3P B6 NOARK – circuit breaker 3-pole, 6A, characteristic B, 6 kA, 100049, 3P, 6 A. Key data: NOARK Ex9BN. Exact technical data for selecting the miniature circuit breaker type.

On request
9,71 €
excl. VAT · 11,75 € incl. VAT
OUR TIP

Ex9BN 3P C32, NOARK, circuit breaker 3-pole, 32A, characteristic C, 6 kA, 100146, 3P, 32 A

Cat. no.: Ex9BN 3P C32

Ex9BN 3P C32 NOARK – circuit breaker 3-pole, 32A, characteristic C, 6 kA, 100146, 3P, 32 A. Key data: NOARK Ex9BN. Exact technical data for selecting the miniature circuit breaker type.

On request
9,88 €
excl. VAT · 11,95 € incl. VAT
OUR TIP

Ex9BN 3P C16, NOARK, circuit breaker 3-pole, 16A, characteristic C, 6 kA, 100143, 3P, 16 A

Cat. no.: Ex9BN 3P C16

Ex9BN 3P C16 NOARK – circuit breaker 3-pole, 16A, characteristic C, 6 kA, 100143, 3P, 16 A. Key data: NOARK Ex9BN. Exact technical data for selecting the miniature circuit breaker type.

On request
10,50 €
excl. VAT · 12,70 € incl. VAT
OUR TIP

Ex9BN 3P B4, NOARK, circuit breaker 3-pole, 4A, characteristic B, 6 kA, 100048, 3P, 4 A

Cat. no.: Ex9BN 3P B4

Ex9BN 3P B4 NOARK – circuit breaker 3-pole, 4A, characteristic B, 6 kA, 100048, 3P, 4 A. Key data: NOARK Ex9BN. Exact technical data for selecting the miniature circuit breaker type.

On request
10,61 €
excl. VAT · 12,84 € incl. VAT

Prices include the recycling fee.

Circuit breakers and RCDs

Choose circuit breakers and residual current devices according to the faults that the specific circuit must handle safely. The figure in amps, the number of modules or the appearance of the toggle are not a complete brief. The design links the power source, wiring, loads and fault conditions. This category helps distinguish protective functions and prepare data for professional selection; it does not replace the design or verification of the installation.

Circuit breaker, RCD and RCBO

An MCB circuit breaker responds to overcurrent. A residual current device RCCB on its own monitors residual current and has no overcurrent protection of its own. A combined RCBO joins both functions. The distinction is also confirmed by the Schneider Electric technical explanation. The designation “RCD” is therefore not enough: for the specific device, verify whether it is an RCCB or RCBO and how the downstream protection is arranged.

For each offer, read the data sheet for the exact order code. Data taken from another size or a related series may look credible but may not apply to the product being assessed. Unclear data must be resolved before the device is included in the project, not only during its installation.

Orientation in the range

Four values that must not be confused

The rated current In describes the current size of the device. The tripping characteristic of a circuit breaker expresses its response to overcurrent as a function of time. Breaking capacity refers to interrupting the short-circuit current under specified conditions. For an RCD, the rated residual operating current IΔn is also important. Each value answers a different question; a higher number by itself does not mean more suitable protection.

Add the voltage, AC or DC use, number and function of poles, type of residual sensitivity and environmental conditions to the comparison. Separately check coordination with the upstream protection. Selectivity cannot be confirmed by simply comparing two rated currents; request documentation for the specific combination.

Author's example: why the 16 A designation is not enough

The model list contains three devices marked 16 A: a circuit breaker, an RCD alone and a combined RCBO. The match of this number does not make them replacements. The purchase table must have separate columns “protective function”, “voltage”, “poles”, “characteristic” and “residual sensitivity”. An empty mandatory cell means missing documentation, not assumed conformity.

Mounting and diagnostics in context

Before ordering, check the module space, connection terminals, compatibility of the busbar and any auxiliary contact. Entrust mounting, measurement and commissioning to a qualified person. After the protection trips, record the circumstances: the load being switched on, the operating time and other loads started at the same time. Repeated switching on without finding the cause or arbitrarily increasing the current value is not a solution to the fault.

FAQ

Is an RCD a replacement for a circuit breaker?

An RCCB on its own is not. The required protective functions must be provided by a correctly designed assembly or a corresponding combined device.

What should be supplied with a replacement request?

A photo of the whole rating plate, the full code, the circuit diagram and data on the supply and load. Also attach the requirements for coordination of protection and the reason for replacement. The same width is not enough to confirm interchangeability.

Cookies on this website