Phone +420 774 723 123 Cart · 0 · empty

Circuit Breakers and Residual Current Devices

Miniature circuit breakers and residual current devices for protecting electrical circuits and people. The range includes MCBs with B, C and D characteristics, DC circuit breakers, RCDs and combined RCBOs. Choose by rated current, number of poles, characteristic and breaking capacity.

Subcategories

Filters
Found 108 products
OUR TIP

Ex9BN 3P C6, NOARK, circuit breaker 3-pole, 6A, characteristic C, 6 kA, 100139, 3P, 6 A

Cat. no.: Ex9BN 3P C6

Ex9BN 3P C6 NOARK – circuit breaker 3-pole, 6A, characteristic C, 6 kA, 100139, 3P, 6 A. Key data: NOARK Ex9BN. Exact technical data for selecting the miniature circuit breaker type.

On request
10,82 €
excl. VAT · 13,09 € incl. VAT
OUR TIP

Ex9BN 3P C4, NOARK, circuit breaker 3-pole, 4A, characteristic C, 6 kA, 100138, 3P, 4 A

Cat. no.: Ex9BN 3P C4

Ex9BN 3P C4 NOARK – circuit breaker 3-pole, 4A, characteristic C, 6 kA, 100138, 3P, 4 A. Key data: NOARK Ex9BN. Exact technical data for selecting the miniature circuit breaker type.

On request
11,80 €
excl. VAT · 14,28 € incl. VAT

Ex9L-N 2P 25A 30mA, NOARK, residual current device type A, 2P, 25A, 30mA, 230VAC

Cat. no.: Ex9L-N 2P 25A 30mA

NOARK Ex9L-N 2P 25A A 30mA, order no. 108349: type A residual current device, 2-pole, 25A, residual current 30mA, 230VAC, DIN mounting.

On request
21,70 €
excl. VAT · 26,26 € incl. VAT

Ex9L-N 4P 16A 30mA, NOARK, residual current device, 16 A

Cat. no.: Ex9L-N 4P 16A 30mA

Ex9L-N 4P 16A 30mA NOARK – residual current device, 16 A. Key data: 30 mA. Exact technical data for selecting the residual current device / RCBO type.

On request
24,41 €
excl. VAT · 29,54 € incl. VAT

Ex9L-N 4P 25A 30mA, NOARK, residual current device, 4P, 25A, 30mA, type A

Cat. no.: Ex9L-N 4P 25A 30mA

Ex9L-N 4P 25A 30mA, NOARK: four-pole type A residual current device, 25A, residual sensitivity 30mA, without overcurrent protection.

On request
25,03 €
excl. VAT · 30,28 € incl. VAT

Ex9L-N 4P 40A 30mA, NOARK, residual current device type A, 4P, 40A, 30mA, 400VAC

Cat. no.: Ex9L-N 4P 40A 30mA

NOARK Ex9L-N 4P 40A A 30mA, order no. 108362: four-pole type A residual current device, 40A, 30mA, 400VAC, for DIN distribution boards.

On request
25,89 €
excl. VAT · 31,32 € incl. VAT
OUR TIP

Ex9BL-N 1P+N B10 30mA, NOARK, combined residual current device with circuit breaker 1P+N, B10, 10A, 30mA, type A

Cat. no.: Ex9BL-N 1P+N B10 30mA

Ex9BL-N 1P+N B10 30mA, NOARK, combined residual current device with circuit breaker 1P+N, B10, 10A, 30mA, type A. The combined device NOARK Ex9BL-N combines overcurrent protection and residual…

On request
32,72 €
excl. VAT · 39,59 € incl. VAT

Prices include the recycling fee.

Circuit breakers and RCDs

Choose circuit breakers and residual current devices according to the faults that the specific circuit must handle safely. The figure in amps, the number of modules or the appearance of the toggle are not a complete brief. The design links the power source, wiring, loads and fault conditions. This category helps distinguish protective functions and prepare data for professional selection; it does not replace the design or verification of the installation.

Circuit breaker, RCD and RCBO

An MCB circuit breaker responds to overcurrent. A residual current device RCCB on its own monitors residual current and has no overcurrent protection of its own. A combined RCBO joins both functions. The distinction is also confirmed by the Schneider Electric technical explanation. The designation “RCD” is therefore not enough: for the specific device, verify whether it is an RCCB or RCBO and how the downstream protection is arranged.

For each offer, read the data sheet for the exact order code. Data taken from another size or a related series may look credible but may not apply to the product being assessed. Unclear data must be resolved before the device is included in the project, not only during its installation.

Orientation in the range

Four values that must not be confused

The rated current In describes the current size of the device. The tripping characteristic of a circuit breaker expresses its response to overcurrent as a function of time. Breaking capacity refers to interrupting the short-circuit current under specified conditions. For an RCD, the rated residual operating current IΔn is also important. Each value answers a different question; a higher number by itself does not mean more suitable protection.

Add the voltage, AC or DC use, number and function of poles, type of residual sensitivity and environmental conditions to the comparison. Separately check coordination with the upstream protection. Selectivity cannot be confirmed by simply comparing two rated currents; request documentation for the specific combination.

Author's example: why the 16 A designation is not enough

The model list contains three devices marked 16 A: a circuit breaker, an RCD alone and a combined RCBO. The match of this number does not make them replacements. The purchase table must have separate columns “protective function”, “voltage”, “poles”, “characteristic” and “residual sensitivity”. An empty mandatory cell means missing documentation, not assumed conformity.

Mounting and diagnostics in context

Before ordering, check the module space, connection terminals, compatibility of the busbar and any auxiliary contact. Entrust mounting, measurement and commissioning to a qualified person. After the protection trips, record the circumstances: the load being switched on, the operating time and other loads started at the same time. Repeated switching on without finding the cause or arbitrarily increasing the current value is not a solution to the fault.

FAQ

Is an RCD a replacement for a circuit breaker?

An RCCB on its own is not. The required protective functions must be provided by a correctly designed assembly or a corresponding combined device.

What should be supplied with a replacement request?

A photo of the whole rating plate, the full code, the circuit diagram and data on the supply and load. Also attach the requirements for coordination of protection and the reason for replacement. The same width is not enough to confirm interchangeability.

Cookies on this website