6SM316B, Sigma Elektrik, miniature circuit breaker, 3, 16 A, B
6SM316B Sigma Elektrik – miniature circuit breaker, 3, 16 A, B. Key data: 6 kA, 6SM. Exact technical data for selecting the miniature circuit breaker type.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
Miniature circuit breakers and residual current devices for protecting electrical circuits and people. The range includes MCBs with B, C and D characteristics, DC circuit breakers, RCDs and combined RCBOs. Choose by rated current, number of poles, characteristic and breaking capacity.
6SM316B Sigma Elektrik – miniature circuit breaker, 3, 16 A, B. Key data: 6 kA, 6SM. Exact technical data for selecting the miniature circuit breaker type.
6SM325B Sigma Elektrik – circuit breaker 3-phase, 25A, characteristic B, 6kA, (25A/B/3f), 25 A, 6 kA. Key data: 6SM. Exact technical data for selecting the miniature circuit breaker type.
8CB30610D, Gregoo, miniature circuit breaker 3P, 6A, characteristic D, 10kA. The three-pole miniature circuit breaker GREGOO 8CB30610D with rated current 6A and characteristic D is designed to…
8CB31610D, Gregoo: miniature circuit breaker 3P/16A with tripping characteristic D and declared breaking capacity 10kA.
8CB32010D, Gregoo: miniature circuit breaker 3P/20A with tripping characteristic D and declared breaking capacity 10kA.
AX3111 Sigma Elektrik – NOARK, auxiliary changeover contact for circuit breakers type Ex9BN, 100540. Exact technical data for selecting the miniature circuit breaker type.
EKL1-63-1P+N-16A/AC, CHANGAN, two-pole residual current device 1P+N for network 230VAC, rated current 16A, sensitivity 30mA, type AC and conditional short-circuit current 10kA. DIN rail mounting…
EKL1-63-3P+N-16A/AC, CHANGAN, four-pole combined device 3P+N, 16A, IΔn 30mA, type AC, with integrated overcurrent protection.
Ex9L-N 2P 16A 30mA NOARK – residual current device, 16 A. Key data: 30 mA. Exact technical data for selecting the residual current device / RCBO type.
Ex9L-N 4P 40A 100mA, NOARK: four-pole type A residual current device, 40A, residual sensitivity 100mA, without overcurrent protection.
Ex9L-N 2P 40A 30mA, NOARK, residual current device 2P, 40A, 30mA, type A. The two-pole residual current device of the Ex9L-N series is designed to monitor residual current in a single-phase…
6SM106B, Sigma Elektrik, miniature circuit breaker 1P, 6A, characteristic B, 6kA. The single-pole Sigma Electric SND series circuit breaker 6000 for a current of 6A with characteristic B protects the…
6SM106C Sigma Elektrik – circuit breaker 1-phase, 6A, characteristic C, 6kA, (6A/C/1f), 6 A, 6 kA. Key data: 6SM. Exact technical data for selecting the miniature circuit breaker type.
1SM106C Sigma Elektrik – circuit breaker 1-phase, 6A, characteristic C, breaking capacity 10kA, (6A/C/1f), elektronik. Key data: 10 kA, 6 A. Exact technical data for selecting the miniature circuit…
EKM1-63-1P-4A/B CHANGAN – circuit breaker 1-pole, 4A, characteristic B, 6 kA, 4 A, 6kA. Key data: EKM1-OF. Exact technical data for selecting the miniature circuit breaker type.
EKM1-63-1P-16A/B, CHANGAN: miniature circuit breaker 1P/16A with tripping characteristic B and declared breaking capacity 6kA.
EKM1-63H-1P-02A/B, CHANGAN: miniature circuit breaker 1P/2A with tripping characteristic B and declared breaking capacity 10kA.
EKM1-63H-1P-04A/B CHANGAN – circuit breaker 1-pole, 4A, characteristic B, 10kA, 04 A. Key data: EKM1-OF. Exact technical data for selecting the miniature circuit breaker type.
EKM1-63H-1P-10A/B CHANGAN – circuit breaker 1-pole, 10A, characteristic B, 10kA, 10 A. Key data: Value. Exact technical data for selecting the miniature circuit breaker type.
EKM1-63-1P-02A/C CHANGAN – circuit breaker 1-pole, 2A, characteristic C, 6 kA, 2 A, 6kA. Key data: Value. Exact technical data for selecting the miniature circuit breaker type.
EKM1-63DC-1P-01A/C, CHANGAN, circuit breaker for DC circuits 1P, 1A, characteristic C, 250VDC, 6kA. DC circuit breaker EKM1-63DC for protecting DC distribution systems; 250VDC applies to the…
Ex9BN 1P B6, NOARK, miniature circuit breaker 1P, 6A, characteristic B, 6kA. Miniature circuit breaker Ex9BN protects single-phase or three-phase branches according to the number of poles 1P.
Ex9BN 1P B10, NOARK: miniature circuit breaker 1P, 10A, characteristic B; breaking capacity Icn 6kA according to EN 60898-1.
Ex9BN 1P B16, NOARK, miniature circuit breaker 1P, 16A, characteristic B, Icn 6kA. Single-pole circuit breaker Ex9BN with characteristic B and current 16A for protecting AC circuits against overload…
Ex9BN 1P C6, NOARK: miniature circuit breaker 1P, 6A, characteristic C; breaking capacity Icn 6kA according to EN 60898-1.
Prices include the recycling fee.
Choose circuit breakers and residual current devices according to the faults that the specific circuit must handle safely. The figure in amps, the number of modules or the appearance of the toggle are not a complete brief. The design links the power source, wiring, loads and fault conditions. This category helps distinguish protective functions and prepare data for professional selection; it does not replace the design or verification of the installation.
An MCB circuit breaker responds to overcurrent. A residual current device RCCB on its own monitors residual current and has no overcurrent protection of its own. A combined RCBO joins both functions. The distinction is also confirmed by the Schneider Electric technical explanation. The designation “RCD” is therefore not enough: for the specific device, verify whether it is an RCCB or RCBO and how the downstream protection is arranged.
For each offer, read the data sheet for the exact order code. Data taken from another size or a related series may look credible but may not apply to the product being assessed. Unclear data must be resolved before the device is included in the project, not only during its installation.
The rated current In describes the current size of the device. The tripping characteristic of a circuit breaker expresses its response to overcurrent as a function of time. Breaking capacity refers to interrupting the short-circuit current under specified conditions. For an RCD, the rated residual operating current IΔn is also important. Each value answers a different question; a higher number by itself does not mean more suitable protection.
Add the voltage, AC or DC use, number and function of poles, type of residual sensitivity and environmental conditions to the comparison. Separately check coordination with the upstream protection. Selectivity cannot be confirmed by simply comparing two rated currents; request documentation for the specific combination.
The model list contains three devices marked 16 A: a circuit breaker, an RCD alone and a combined RCBO. The match of this number does not make them replacements. The purchase table must have separate columns “protective function”, “voltage”, “poles”, “characteristic” and “residual sensitivity”. An empty mandatory cell means missing documentation, not assumed conformity.
Before ordering, check the module space, connection terminals, compatibility of the busbar and any auxiliary contact. Entrust mounting, measurement and commissioning to a qualified person. After the protection trips, record the circumstances: the load being switched on, the operating time and other loads started at the same time. Repeated switching on without finding the cause or arbitrarily increasing the current value is not a solution to the fault.
An RCCB on its own is not. The required protective functions must be provided by a correctly designed assembly or a corresponding combined device.
A photo of the whole rating plate, the full code, the circuit diagram and data on the supply and load. Also attach the requirements for coordination of protection and the reason for replacement. The same width is not enough to confirm interchangeability.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.