Phone +420 774 723 123 Cart · 0 · empty

Electrical Consumables

Electrical consumables – cable lugs and ferrules, cable glands, conduits and conduit glands, cable ties, cable chains, trunking and DIN rails, sockets and bells. Choose by conductor cross-section and mounting method.

Subcategories

Filters
Found 101 products
IN STOCK

ONKA 8162-100, ONKA, 8162, crimp cable ferrule - pack of 100Ks

Cat. no.: ONKA 8162-100

ONKA 8162-100 ONKA – 8162, crimp cable ferrule - pack of 100Ks. Key data: 0.75 × 8 mm, 100 pcs. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
2,87 €
excl. VAT · 3,47 € incl. VAT
IN STOCK

ONKA 8014-100, ONKA, 8014, crimp cable ferrule - pack of 100 pcs

Cat. no.: ONKA 8014-100

ONKA 8014-100 ONKA – 8014, crimp cable ferrule - pack of 100 pcs. Key data: 1.0 × 8 mm. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
2,87 €
excl. VAT · 3,47 € incl. VAT
IN STOCK

ONKA 8164-100, ONKA, 8164, crimp cable ferrule - pack of 100Ks

Cat. no.: ONKA 8164-100

ONKA 8164-100 ONKA – 8164, crimp cable ferrule - pack of 100Ks. Key data: 1 × 8 mm, 100 pcs. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
2,95 €
excl. VAT · 3,57 € incl. VAT
IN STOCK

ONKA 8166-100, ONKA, 8166, crimp cable ferrule - pack of 100ks

Cat. no.: ONKA 8166-100

ONKA 8166-100 ONKA – 8166, crimp cable ferrule - pack of 100ks. Key data: 1.5 × 8 mm, 100 pcs. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
3,24 €
excl. VAT · 3,92 € incl. VAT
OUR TIP IN STOCK

T1-E 25x60 G01166, IBOCO, plastic wiring duct

Cat. no.: T1-E 25x60 G01166

T1-E 25x60 G01166 IBOCO – plastic wiring duct. Key data: 25x60. Exact technical data for selecting the DIN rail / wiring duct type.

In stock 5 or more pcs · in multiples of 2 pcs
3,32 €
excl. VAT · 4,01 € incl. VAT
OUR TIP IN STOCK

EPRFR2K, EMAS, socket; supply: 230 V AC; for DIN rail; colour: red

Cat. no.: EPRFR2K

EPRFR2K EMAS – socket; supply: 230 V AC; for DIN rail; colour: red. Exact technical data for selecting the industrial socket / plug type.

In stock 5 or more pcs
3,40 €
excl. VAT · 4,12 € incl. VAT
OUR TIP IN STOCK

T1-E 40x40 G01134, IBOCO, plastic wiring duct

Cat. no.: T1-E 40x40 G01134

T1-E 40x40 G01134 IBOCO – plastic wiring duct. Key data: 40x40. Exact technical data for selecting the DIN rail / wiring duct type.

In stock 4 ks · in multiples of 2 pcs
3,40 €
excl. VAT · 4,11 € incl. VAT
IN STOCK

ONKA-8170-100, ONKA, 8170, crimp cable ferrule - pack of 100ks

Cat. no.: ONKA-8170-100

ONKA-8170-100 ONKA – 8170, crimp cable ferrule - pack of 100ks. Key data: 4 × 12 mm, 100 pcs. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
3,52 €
excl. VAT · 4,26 € incl. VAT
OUR TIP IN STOCK

PC-104-0B, PC Electric, panel-mounted socket 16A, 230VAC

Cat. no.: PC-104-0B

PC-104-0B, PC Electric, panel-mounted socket 16A for 230VAC. Version and basic data confirmed by TECHNOLINE according to the product export.

In stock 5 or more pcs
3,60 €
excl. VAT · 4,36 € incl. VAT
OUR TIP IN STOCK

ECE416V5PU, EMAS, industrial CEE cable socket, 4-pole (3P+PE), 16A, 380–415VAC, IP44

Cat. no.: ECE416V5PU

ECE416V5PU, EMAS, 4-pole (3P+PE) CEE cable socket with a current of 16A, voltage class 380–415VAC, screw terminals and protection rating IP44.

In stock 5 or more pcs
3,66 €
excl. VAT · 4,43 € incl. VAT
OUR TIP IN STOCK

T1-E 40x60 G01107, IBOCO, plastic wiring duct

Cat. no.: T1-E 40x60 G01107

T1-E 40x60 G01107 IBOCO – plastic wiring duct. Key data: 40x60. Exact technical data for selecting the DIN rail / wiring duct type.

In stock 5 or more pcs · in multiples of 2 pcs
3,97 €
excl. VAT · 4,80 € incl. VAT
IN STOCK

ONKA 8025-200, ONKA, 8025, crimp cable ferrule - pack of 200 pcs

Cat. no.: ONKA 8025-200

ONKA 8025-200 ONKA – 8025, crimp cable ferrule - pack of 200 pcs. Key data: 4 × 10 mm. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
4,10 €
excl. VAT · 4,96 € incl. VAT
IN STOCK

ONKA 8017-500, ONKA, 8017, crimp cable ferrule - pack of 500 pcs

Cat. no.: ONKA 8017-500

ONKA 8017-500 ONKA – 8017, crimp cable ferrule - pack of 500 pcs. Key data: 1.5 × 8 mm. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
5,71 €
excl. VAT · 6,91 € incl. VAT
IN STOCK

ONKA 8021-500, ONKA, 8021, crimp cable ferrule - pack of 500 pcs

Cat. no.: ONKA 8021-500

ONKA 8021-500 ONKA – 8021, crimp cable ferrule - pack of 500 pcs. Key data: 2.5 × 8 mm. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
5,71 €
excl. VAT · 6,91 € incl. VAT
IN STOCK

EKBT, CHANGAN, bell transformer, 230/8, 12, 24V AC, 8VA, , CHANA

Cat. no.: EKBT

EKBT CHANGAN – bell transformer, 230/8, 12, 24V AC, 8VA, , CHANA. Key data: 230 V AC, taps 8, 12, 24V AC, 24 V AC. Exact technical data for selecting the bell device type.

In stock 2 ks
5,85 €
excl. VAT · 7,08 € incl. VAT
IN STOCK

ONKA 8168-250, ONKA, 8168, crimp cable ferrule - pack of 250Ks

Cat. no.: ONKA 8168-250

ONKA 8168-250 ONKA – 8168, crimp cable ferrule - pack of 250Ks. Key data: 2.5 × 10 mm, 250 pcs. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
6,14 €
excl. VAT · 7,43 € incl. VAT
IN STOCK

ONKA 8161-500, ONKA, 8161, crimp cable ferrule - pack of 500Ks

Cat. no.: ONKA 8161-500

ONKA 8161-500 ONKA – 8161, crimp cable ferrule - pack of 500Ks. Key data: 0.5 × 8 mm, 500 pcs. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
7,00 €
excl. VAT · 8,47 € incl. VAT
IN STOCK

ONKA 8162-500, ONKA, 8162, crimp cable ferrule - pack of 500Ks

Cat. no.: ONKA 8162-500

ONKA 8162-500 ONKA – 8162, crimp cable ferrule - pack of 500Ks. Key data: 0.75 × 8 mm, 500 pcs. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
7,00 €
excl. VAT · 8,47 € incl. VAT
IN STOCK

ONKA 8164-500, ONKA, 8164, crimp cable ferrule - pack of 500Ks

Cat. no.: ONKA 8164-500

ONKA 8164-500 ONKA – 8164, crimp cable ferrule - pack of 500Ks. Key data: 1.0 × 8 mm, 500 pcs. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
7,25 €
excl. VAT · 8,77 € incl. VAT
IN STOCK

ONKA 8166-500, ONKA, 8166, crimp cable ferrule - pack of 500ks

Cat. no.: ONKA 8166-500

ONKA 8166-500 ONKA – 8166, crimp cable ferrule - pack of 500ks. Key data: 1.5 × 8 mm, 500 pcs. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
7,70 €
excl. VAT · 9,32 € incl. VAT
IN STOCK

ONKA 8168-500, ONKA, 8168, crimp cable ferrule - pack of 500Ks

Cat. no.: ONKA 8168-500

ONKA 8168-500 ONKA – 8168, crimp cable ferrule - pack of 500Ks. Key data: 2.5 × 10 mm, 500 pcs. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
8,92 €
excl. VAT · 10,80 € incl. VAT
IN STOCK

ONKA 8010-1000, ONKA, 8010, crimp cable ferrule - pack of 1000 pcs

Cat. no.: ONKA 8010-1000

ONKA 8010-1000 ONKA – 8010, crimp cable ferrule - pack of 1000 pcs. Key data: 0.75 × 8 mm. Exact technical data for selecting the crimp cable terminal type.

In stock 5 or more pcs
9,05 €
excl. VAT · 10,95 € incl. VAT

Prices include the recycling fee.

Electrical consumables

Electrical consumables link the design of electrical equipment with its actual mechanical execution. A well-chosen terminal is no help if the conductor termination does not fit into it; a quality cable in turn needs a suitable wall entry and a well-thought-out route. This category brings together material for terminating, organising, protecting and fixing cabling as well as selected connection and doorbell devices. When selecting, it pays to proceed interface by interface, not just by brand or the nearest size.

Overview of subcategories

Start with the function of the part, not its similar appearance

For stranded conductors connected to suitable terminals, use insulated crimp ferrules; crimp cable lugs are used for a screw connection with a ring. A ferrule and a lug are therefore not two interchangeable variants of the same termination. They differ in contact shape, the space required for connection and the tool used to make the joint. The cross-section figure alone does not determine whether the termination suits a specific terminal.

For organising conductors inside a control cabinet, choose trunking and suitable fixing elements. A DIN rail carries devices; it is not a substitute for cable trunking. A conduit protects the route, while its end fitting handles the transition to the equipment. A cable gland works with the cable sheath and the opening in the wall. For moving equipment, routing cables in an energy chain is added. Each of these parts answers a different design question.

Four values that must not be confused

The conductor cross-section in mm² describes the conductive part. The outer diameter of an insulated conductor or of the whole cable in millimetres is a different dimension, needed for example when assessing the entry and the space. The length of the metal sleeve of a ferrule is not the same as the overall length with the insulating collar. The nominal thread of a gland, in turn, does not say how wide a cable its seal will actually accept.

In the working list, therefore record electrical and mechanical data separately. For termination, it is the cross-section, conductor construction and receiving terminal. For the entry, add the outer cable diameter, the thread or mounting hole, the wall thickness and the environment. The need to assess the cable, thread and sealing interface together is explained in the LAPP technical guide to cable glands. The specific ranges, however, must come from the data sheet of the product being ordered.

A fixed route and repeated movement require a different brief

For a fixed installation, draw the route including entries into the control cabinet, slack at the doors and access to devices. For movement, also describe the stroke, the position of the fixed points, the smallest permissible cable radius and the duty cycle. Flexible cable chains choose as part of a moving system, not as a simple substitute for plastic trunking.

The chain length reflects the stroke arrangement and the allowance for the bend. The manufacturer igus distinguishes these relationships in its documentation for calculating energy chain length. The dimensional similarity of another series does not justify adopting its design tables. Already at the design stage, leave space for the end brackets and any chain guidance; the moving bend must not intrude into the operator area or adjacent mechanics.

Mounting interfaces determine the result

For a crimped joint, the conductor, termination and crimping tool belong to a single work procedure. The suitability of this combination and the quality of workmanship are emphasised by Weidmüller in its ferrule documentation. Therefore use the collar colour as an aid to organising work, not as the sole proof of the cross-section. With a twin ferrule, the termination must also be permitted by the receiving terminal.

For a conduit, check its size and profile, compatibility of the fitting and how the route is fixed. For a cable tie, the permissible bundle, material and fixing method are essential. An adhesive base needs a suitable substrate; the mere presence of an adhesive layer is no proof of long-term load capacity in all positions. Each interface has its own conditions and the resulting assembly must meet them all at once.

Worked example: bill of materials for a small assembly

Consider our own production plan for eight identical assemblies. Each has 24 separate stranded conductors and both ends are to be terminated with a single ferrule permitted by the terminals in question. The basic requirement is 8 × 24 × 2 = 384 pieces. Another twelve ferrules are needed for twelve test terminations. In total, the plan therefore counts on 396 pieces, not 192 based on the number of conductors.

If the selected order item contained one hundred pieces, four packs would cover exactly this model requirement. Such a calculation does not, however, merge different cross-sections or lengths into one item: with two types of termination, the quantities are itemised separately. Openings in the enclosure, glands, fixing bases and conduit ends are counted separately in the same way. The reserve is determined by your own production process; it is not a universal percentage.

Ordering and maintenance without unnecessary mix-ups

For small material, a short internal description containing the function, size, series and order unit helps. On receipt, distinguish between a piece, a bag and a whole pack. In the workshop, keep similar terminations separate and attach information on the tool used. When repairing, do not select a replacement only by colour or photo; also compare the size of the contact part and the documentation of the connected equipment.

Socket and doorbell devices belong in this overview as separate functional parts. For sockets and plugs 230V / 400V the complete connection system is assessed; for a transformer, the powered appliance and its consumption. The mains part of the equipment must be designed and carried out by a qualified person. The designation of one part does not transfer the protection rating, current capacity or other properties to an arbitrarily assembled whole.

FAQ

Is a larger accessory size always the safer choice?

No. An oversized termination may fit the conductor or terminal poorly, and an unsuitable sealing range of a gland may not match the cable. The size must suit both sides of the joint.

Can a spare part be identified just by the material designation?

Material is only one piece of information. Add the design series, dimensions, environment, mounting conditions and the function of the original part. For a repair, the complete order code is more useful than a general name.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.