TBPC06-M5, TECHNOLINE, all-metal straight push-in fitting, tube Ø6mm, male thread M5
TBPC06-M5, TECHNOLINE: straight push-in fitting; tube Ø6mm, male thread M5. Push-in connection for pneumatics.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
SMC, Pneuflex and other pneumatic accessories – push-in fittings, threaded fittings, reducers, flow control valves, silencers, plugs, blow guns and suction cups. Choose by tube diameter and connection thread.
TBPC06-M5, TECHNOLINE: straight push-in fitting; tube Ø6mm, male thread M5. Push-in connection for pneumatics.
KQ2H04-01AS, SMC: straight push-in fitting with male thread; tube Ø4mm, thread R1/8. Dimensions and use according to the catalogue series.
KQ2R23-06A, SMC: plug-in reducer into a push-in fitting. tube Ø3.2mm → stem for Ø6mm port. Use in pneumatic distribution and verified mounting criteria.
TBPCF04-G01, TECHNOLINE: straight push-in fitting with female thread; tube Ø4mm, female thread G1/8. Push-in connection for pneumatics.
TBPC06-M6, TECHNOLINE: straight push-in fitting; tube Ø6mm, male thread M6. Push-in connection for pneumatics.
KQ2H06-00A, SMC, straight fitting, 2× tube Ø6mm. Straight connection of two tubes; suitable for extending a pneumatic route without a thread.
KQ2H04-00A, SMC, straight fitting, 2× tube Ø4mm. Straight connection of two tubes; suitable for extending a pneumatic route without a thread.
KQ2H06-01AS, SMC: straight push-in fitting with male thread; tube Ø6mm, thread R1/8. Dimensions and use according to the catalogue series.
TPCF06-G04, TECHNOLINE: straight push-in fitting with female thread; tube Ø6mm, female thread G1/2. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
TPCF08-G01, TECHNOLINE: straight push-in fitting with female thread; tube Ø8mm, female thread G1/8. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
TPCF10-G01, TECHNOLINE: straight push-in fitting with female thread; tube Ø10mm, female thread G1/8. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
KQ2L08-99A, SMC, elbow fitting 90°, plug-in stem and tube Ø8mm. A plug-in adapter into a push-in counterpart with a separate tube connection.
KQ2R06-10A, SMC: plug-in reducer into a push-in fitting. tube Ø6mm → stem for Ø10mm port. Use in pneumatic distribution and verified mounting criteria.
KQ2R04-10A, SMC: plug-in reducer into a push-in fitting. tube Ø4mm → stem for Ø10mm port. Use in pneumatic distribution and verified mounting criteria.
KQ2R06-12A, SMC: plug-in reducer into a push-in fitting. tube Ø6mm → stem for Ø12mm port. Use in pneumatic distribution and verified mounting criteria.
TBPCF04-G02, TECHNOLINE: straight push-in fitting with female thread; tube Ø4mm, female thread G1/4. Push-in connection for pneumatics.
TBPCF04-M5, TECHNOLINE: straight push-in fitting with female thread; tube Ø4mm, female thread M5. Push-in connection for pneumatics.
KQ2L02-M5A, SMC, elbow fitting 90°, tube Ø2mm, male M5. Elbow connection of the tube to threaded port M5; changes the line direction at the component.
KQ2C08-00A, SMC: plug for open tube end. Ø8mm. Use in pneumatic distribution and verified mounting criteria.
TBPCF06-G01, TECHNOLINE: straight push-in fitting with female thread; tube Ø6mm, female thread G1/8. Push-in connection for pneumatics.
KQ2C10-00A, SMC: plug for open tube end. Ø10mm. Use in pneumatic distribution and verified mounting criteria.
KQ2H06-M5A, SMC: straight push-in fitting with male thread; tube Ø6mm, thread M5. Dimensions and use according to the catalogue series.
TBESL-G03, TECHNOLINE: adjustable exhaust silencer. male thread G3/8. Use in pneumatic distribution and verified mounting criteria.
TBPCF08-G01, TECHNOLINE: straight push-in fitting with female thread; tube Ø8mm, female thread G1/8. Push-in connection for pneumatics.
TPCF08-G03, TECHNOLINE: straight push-in fitting with female thread; tube Ø8mm, female thread G3/8. Series 0–10bar, 0 to +60°C. Push-in connection for pneumatics.
Prices include the recycling fee.
Pneumatic accessories connect individual parts of the air circuit and help adapt its arrangement to a specific machine. When selecting, you need to know not only the part designation, but also both connected counterparts, the required function and operating conditions. A similar appearance of fittings or the same brand do not by themselves confirm interchangeability. This category is a signpost for line design, air distribution, flow adjustment and vacuum gripping.
Mechanical interface: record the full connection designation on both sides. For the tube, distinguish the outer and inner diameter; for the thread, its type, size and sealing method. Also check the space for mounting and service; the correct part may not be suitable for an installation that is too tight.
Function: draw where the medium should flow from and to. Connecting, branching, blanking, throttling and gripping are different tasks. For more complex accessories, compare the diagram and the full order code, not just the first part of the name.
Operating conditions: verify the permissible medium, pressure, temperature and environment for the specific version in the manufacturer's documentation. Assess use in vacuum separately. Do not derive the permitted range of the whole assembly from a parameter of one of its elements.
Let us consider four workstations, each with two separate lines. If each line forms one uninterrupted section, eight sections have a total of sixteen ends to connect. Dividing all eight sections into two parts adds eight intermediate fittings and sixteen more tube ends. This is our own inventory example, not a calculation of pressure loss or probability of leakage. It helps reveal missing counterparts and distinguish a spare piece from a part actually needed in the assembly.
Before intervention, shut down the equipment according to its instructions and secure it against unexpected movement. Disconnect lines only after safely removing pressure; for vacuum gripping, first secure the transported object. Take the mounting procedure, tightening and insertion check from the instructions of the specific accessory. After assembly, verify tightness, actual function and maintenance access during controlled commissioning.
In case of a leak, first determine its location, then check the counterpart, line size, seal condition and mechanical stress on the joint. In case of slow movement, monitor the whole supply and exhaust. Random replacement of one part without verifying the cause can leave the original problem in another part of the circuit.
A photo helps determine the shape. For ordering, however, add dimensions, exact connection, function and operating limitations. For a replacement, record the original code and also compare the counterpart.
Attach a simple circuit diagram, a list of connections, tube sizes and operating conditions. Mark what you already have and what should be part of the delivery; this makes the list and the compatibility check more precise.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.