Phone +420 774 723 123 Cart · 0 · empty

Pneumatic accessories

SMC, Pneuflex and other pneumatic accessories – push-in fittings, threaded fittings, reducers, flow control valves, silencers, plugs, blow guns and suction cups. Choose by tube diameter and connection thread.

Subcategories

Filters
Found 696 products

AS2211F-01-06SA, SMC, elbow one-way speed controller with check function, tube Ø6mm, thread R1/8, meter-in (supply throttling)

Cat. no.: AS2211F-01-06SA

AS2211F-01-06SA, SMC: elbow one-way speed controller with check function. tube Ø6mm, thread R1/8, meter-in (supply throttling). Use in pneumatic distribution and verified mounting criteria.

On request
10,93 €
excl. VAT · 13,22 € incl. VAT

AS2301F-01-06S, SMC, elbow one-way speed controller with check function, tube Ø6mm, thread R1/8, meter-out (exhaust throttling), universal, swivel according to the AS series

Cat. no.: AS2301F-01-06S

AS2301F-01-06S, SMC: elbow one-way speed controller with check function. tube Ø6mm, thread R1/8, meter-out (exhaust throttling), universal, swivel according to the AS series. Use in pneumatic…

On request
11,05 €
excl. VAT · 13,37 € incl. VAT

KQ2VD06-02AS, SMC, elbow double manifold with thread, tube Ø6mm, male R1/4

Cat. no.: KQ2VD06-02AS

KQ2VD06-02AS, SMC, elbow double manifold with thread, tube Ø6mm, male R1/4. Air branching from threaded port R1/4 into several tube outlets. With pre-applied thread seal.

On request
11,05 €
excl. VAT · 13,37 € incl. VAT
OUR TIP

KQ2L16-04AS, SMC, elbow fitting 90°, tube Ø16mm, male R1/2

Cat. no.: KQ2L16-04AS

KQ2L16-04AS, SMC, elbow fitting 90°, tube Ø16mm, male R1/2. Elbow connection of the tube to threaded port R1/2; changes the line direction at the component. With pre-applied thread seal.

On request
11,34 €
excl. VAT · 13,72 € incl. VAT

ANA1-03, SMC, pneumatic exhaust silencer, thread R3/8, body size 1

Cat. no.: ANA1-03

ANA1-03, SMC: pneumatic exhaust silencer. thread R3/8, body size 1. Use in pneumatic distribution and verified mounting criteria.

On request
11,46 €
excl. VAT · 13,87 € incl. VAT

ANB1-C10, SMC, pneumatic exhaust silencer, push-in connection Ø10mm, body size 1

Cat. no.: ANB1-C10

ANB1-C10, SMC: pneumatic exhaust silencer. push-in connection Ø10mm, body size 1. Use in pneumatic distribution and verified mounting criteria.

On request
11,46 €
excl. VAT · 13,87 € incl. VAT
OUR TIP

AN40-04, SMC, pneumatic exhaust silencer, thread R1/2, body size 40

Cat. no.: AN40-04

AN40-04, SMC: pneumatic exhaust silencer. thread R1/2, body size 40. Use in pneumatic distribution and verified mounting criteria.

On request
11,67 €
excl. VAT · 14,12 € incl. VAT

AS2201F-01-08A, SMC, elbow one-way speed controller with check function, tube Ø8mm, thread R1/8, meter-out (exhaust throttling)

Cat. no.: AS2201F-01-08A

AS2201F-01-08A, SMC: elbow one-way speed controller with check function. tube Ø8mm, thread R1/8, meter-out (exhaust throttling). Use in pneumatic distribution and verified mounting criteria.

On request
11,67 €
excl. VAT · 14,12 € incl. VAT

KQ2E12-00A, SMC, bulkhead fitting, tube Ø12mm on both sides

Cat. no.: KQ2E12-00A

KQ2E12-00A, SMC, bulkhead fitting, tube Ø12mm on both sides. Fixed pass-through of a pneumatic line through a mounting plate or cabinet wall.

On request
11,67 €
excl. VAT · 14,12 € incl. VAT

KQ2E12-03A, SMC, bulkhead fitting, tube Ø12mm, female Rc3/8

Cat. no.: KQ2E12-03A

KQ2E12-03A, SMC, bulkhead fitting, tube Ø12mm, female Rc3/8. Fixed pass-through of a pneumatic line through a mounting plate or cabinet wall.

On request
11,71 €
excl. VAT · 14,17 € incl. VAT

KQ2U12-16A, SMC, Y-connector, reducer Ø12mm↔Ø16mm

Cat. no.: KQ2U12-16A

KQ2U12-16A, SMC, Y-connector, reducer Ø12mm↔Ø16mm. Angled Y-branching for routing three branches with suitable tube geometry.

On request
11,87 €
excl. VAT · 14,36 € incl. VAT
OUR TIP

AS2201F-01-06SA, SMC, elbow one-way speed controller with check function, tube Ø6mm, thread R1/8, meter-out (exhaust throttling)

Cat. no.: AS2201F-01-06SA

AS2201F-01-06SA, SMC: elbow one-way speed controller with check function. tube Ø6mm, thread R1/8, meter-out (exhaust throttling). Use in pneumatic distribution and verified mounting criteria.

On request
11,89 €
excl. VAT · 14,38 € incl. VAT

AS1301F-M3-04, SMC, elbow one-way speed controller with check function, tube Ø4mm, thread M3, meter-out (exhaust throttling), universal, swivel according to the AS series

Cat. no.: AS1301F-M3-04

AS1301F-M3-04, SMC: elbow one-way speed controller with check function. tube Ø4mm, thread M3, meter-out (exhaust throttling), universal, swivel according to the AS series. Use in pneumatic…

On request
12,08 €
excl. VAT · 14,61 € incl. VAT

AS2201F-G01-06A, SMC, elbow one-way speed controller with check function, tube Ø6mm, thread G1/8, meter-out (exhaust throttling)

Cat. no.: AS2201F-G01-06A

AS2201F-G01-06A, SMC: elbow one-way speed controller with check function. tube Ø6mm, thread G1/8, meter-out (exhaust throttling). Use in pneumatic distribution and verified mounting criteria.

On request
12,24 €
excl. VAT · 14,81 € incl. VAT

AS2201F-G01-08A, SMC, elbow one-way speed controller with check function, tube Ø8mm, thread G1/8, meter-out (exhaust throttling)

Cat. no.: AS2201F-G01-08A

AS2201F-G01-08A, SMC: elbow one-way speed controller with check function. tube Ø8mm, thread G1/8, meter-out (exhaust throttling). Use in pneumatic distribution and verified mounting criteria.

On request
12,24 €
excl. VAT · 14,81 € incl. VAT

AS2002F-06, SMC, in-line speed / flow regulator, tube Ø6mm, body size 200

Cat. no.: AS2002F-06

AS2002F-06, SMC: in-line speed / flow regulator. tube Ø6mm, body size 200. Use in pneumatic distribution and verified mounting criteria.

On request
12,32 €
excl. VAT · 14,91 € incl. VAT

KQ2VD08-04AS, SMC, elbow double manifold with thread, tube Ø8mm, male R1/2

Cat. no.: KQ2VD08-04AS

KQ2VD08-04AS, SMC, elbow double manifold with thread, tube Ø8mm, male R1/2. Air branching from threaded port R1/2 into several tube outlets. With pre-applied thread seal.

On request
12,69 €
excl. VAT · 15,35 € incl. VAT

AS2201F-G02-08A, SMC, elbow one-way speed controller with check function, tube Ø8mm, thread G1/4, meter-out (exhaust throttling)

Cat. no.: AS2201F-G02-08A

AS2201F-G02-08A, SMC: elbow one-way speed controller with check function. tube Ø8mm, thread G1/4, meter-out (exhaust throttling). Use in pneumatic distribution and verified mounting criteria.

On request
12,89 €
excl. VAT · 15,60 € incl. VAT

AS2201F-G02-06A, SMC, elbow one-way speed controller with check function, tube Ø6mm, thread G1/4, meter-out (exhaust throttling)

Cat. no.: AS2201F-G02-06A

AS2201F-G02-06A, SMC: elbow one-way speed controller with check function. tube Ø6mm, thread G1/4, meter-out (exhaust throttling). Use in pneumatic distribution and verified mounting criteria.

On request
12,89 €
excl. VAT · 15,60 € incl. VAT
OUR TIP

AS1002F-06, SMC, in-line speed / flow regulator, tube Ø6mm, body size 100

Cat. no.: AS1002F-06

AS1002F-06, SMC: in-line speed / flow regulator. tube Ø6mm, body size 100. Use in pneumatic distribution and verified mounting criteria.

On request
12,97 €
excl. VAT · 15,69 € incl. VAT
OUR TIP

AS1002F-04, SMC, in-line speed / flow regulator, tube Ø4mm, body size 100

Cat. no.: AS1002F-04

AS1002F-04, SMC: in-line speed / flow regulator. tube Ø4mm, body size 100. Use in pneumatic distribution and verified mounting criteria.

On request
12,98 €
excl. VAT · 15,70 € incl. VAT

KCE06-00, SMC, self-sealing bulkhead fitting, tube Ø6mm

Cat. no.: KCE06-00

KCE06-00, SMC, self-sealing bulkhead fitting, tube Ø6mm. A self-sealing joint for disconnectable pneumatic assemblies; requires the correct counterpart.

On request
13,10 €
excl. VAT · 15,85 € incl. VAT

VHK3A-02S-08F, SMC, push-in fitting

Cat. no.: VHK3A-02S-08F

VHK3A-02S-08F, SMC, push-in fitting. A pneumatic fitting connects a tube to another element of the distribution or connects two tubes. The tube diameter, thread, shape and sealing method are decisive.

On request
13,10 €
excl. VAT · 15,85 € incl. VAT

Prices include the recycling fee.

Pneumatic accessories

Pneumatic accessories connect individual parts of the air circuit and help adapt its arrangement to a specific machine. When selecting, you need to know not only the part designation, but also both connected counterparts, the required function and operating conditions. A similar appearance of fittings or the same brand do not by themselves confirm interchangeability. This category is a signpost for line design, air distribution, flow adjustment and vacuum gripping.

Select the branch according to the task in the circuit

  • Threaded fitting: connection to a specific threaded port of the equipment.
  • Push-in fittings: selecting a connection for the corresponding pipe or tube.
  • Bulkhead fittings: passing the line through a panel with resolved fixing.
  • Reducing fittings: connecting different connection sizes.
  • Flow control valves: flow adjustment taking into account the direction and function of the valve.
  • Silencers: exhaust accessories, which are also selected according to flow requirements.
  • Blanking plugs: closing the connection with a corresponding version.
  • Blow gun: manual work with air according to the rules of the given workplace.
  • Pneumatic suction cups: contact of the vacuum gripper with the surface of the handled part.

Three checks before ordering

Mechanical interface: record the full connection designation on both sides. For the tube, distinguish the outer and inner diameter; for the thread, its type, size and sealing method. Also check the space for mounting and service; the correct part may not be suitable for an installation that is too tight.

Function: draw where the medium should flow from and to. Connecting, branching, blanking, throttling and gripping are different tasks. For more complex accessories, compare the diagram and the full order code, not just the first part of the name.

Operating conditions: verify the permissible medium, pressure, temperature and environment for the specific version in the manufacturer's documentation. Assess use in vacuum separately. Do not derive the permitted range of the whole assembly from a parameter of one of its elements.

Model list of connection points

Let us consider four workstations, each with two separate lines. If each line forms one uninterrupted section, eight sections have a total of sixteen ends to connect. Dividing all eight sections into two parts adds eight intermediate fittings and sixteen more tube ends. This is our own inventory example, not a calculation of pressure loss or probability of leakage. It helps reveal missing counterparts and distinguish a spare piece from a part actually needed in the assembly.

Mounting and troubleshooting

Before intervention, shut down the equipment according to its instructions and secure it against unexpected movement. Disconnect lines only after safely removing pressure; for vacuum gripping, first secure the transported object. Take the mounting procedure, tightening and insertion check from the instructions of the specific accessory. After assembly, verify tightness, actual function and maintenance access during controlled commissioning.

In case of a leak, first determine its location, then check the counterpart, line size, seal condition and mechanical stress on the joint. In case of slow movement, monitor the whole supply and exhaust. Random replacement of one part without verifying the cause can leave the original problem in another part of the circuit.

FAQ

Can I replace a fitting based on a photo?

A photo helps determine the shape. For ordering, however, add dimensions, exact connection, function and operating limitations. For a replacement, record the original code and also compare the counterpart.

How to prepare documentation for selecting accessories?

Attach a simple circuit diagram, a list of connections, tube sizes and operating conditions. Mark what you already have and what should be part of the delivery; this makes the list and the compatibility check more precise.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.