Phone +420 774 723 123 Cart · 0 · empty

Incremental Encoders

Incremental encoders convert rotation or movement into a sequence of pulses from which the control system determines position, speed and direction of rotation. They are used for length measurement, speed monitoring, drive synchronisation and as feedback for servo drives and frequency inverters. Here you will find encoders with solid and hollow shafts, with flanges and for mounting on a motor shaft, with resolutions from several tens to several thousand pulses per revolution. They are complemented by measuring wheels for measuring belts or material and handwheels for manual control. You can choose by resolution, shaft diameter and type, supply 5 V or 24 V, output type push-pull, open collector or RS422 and by the maximum frequency your PLC input can handle. If needed, contact us and we will gladly help you choose the type for your application.

Subcategories

Filters
Found 17 products

bracket IRC30x/ARC40x, LARM, encoder bracket IRC30x/ARC40x

Cat. no.: držák IRC30x/ARC40x

bracket IRC30x/ARC40x LARM – rotary encoder bracket. Industrial product for automation, measurement and control.

On request
18,05 €
excl. VAT · 21,84 € incl. VAT

bracket IRC31x/ARC41x, LARM, encoder bracket IRC31x/ARC41x

Cat. no.: držák IRC31x/ARC41x

bracket IRC31x/ARC41x LARM – rotary encoder bracket. Industrial product for automation, measurement and control.

On request
18,50 €
excl. VAT · 22,39 € incl. VAT

SP9, LARM, constant-velocity coupling

Cat. no.: SP9

SP9 LARM – constant-velocity coupling for rotary encoder. Industrial product for automation, measurement and control.

On request
24,93 €
excl. VAT · 30,16 € incl. VAT

SV9, LARM, constant-velocity coupling

Cat. no.: SV9

SV9 LARM – constant-velocity coupling for rotary encoder. Industrial product for automation, measurement and control.

On request
35,24 €
excl. VAT · 42,64 € incl. VAT

IRC305/2500PB, LARM, incremental rotary encoder

Cat. no.: IRC305/2500PB

IRC305/2500PB LARM – incremental rotary encoder, cable 1m. Industrial product for automation, measurement and control.

On request
185,48 €
excl. VAT · 224,43 € incl. VAT

IRC320/512PB, LARM, incremental rotary encoder

Cat. no.: IRC320/512PB

IRC320/512PB LARM – incremental rotary encoder, push/pull, cable 1m. Industrial product for automation, measurement and control.

On request
209,75 €
excl. VAT · 253,80 € incl. VAT

IRC305/4096KA, LARM, incremental rotary encoder

Cat. no.: IRC305/4096KA

IRC305/4096KA LARM – incremental rotary encoder. Industrial product for automation, measurement and control.

On request
209,75 €
excl. VAT · 253,80 € incl. VAT

IRC125/1250KB, LARM, incremental rotary encoder

Cat. no.: IRC125/1250KB

IRC125/1250KB LARM – incremental rotary encoder. Industrial product for automation, measurement and control.

On request
217,08 €
excl. VAT · 262,66 € incl. VAT

IRC300/1000KB, LARM, incremental rotary encoder

Cat. no.: IRC300/1000KB

IRC300/1000KB LARM – incremental rotary encoder, push/pull. Industrial product for automation, measurement and control.

On request
219,00 €
excl. VAT · 264,99 € incl. VAT

IRC120/1250KA, LARM, incremental rotary encoder

Cat. no.: IRC120/1250KA

IRC120/1250KA LARM – incremental rotary encoder. Industrial product for automation, measurement and control.

On request
223,09 €
excl. VAT · 269,94 € incl. VAT

IRC536/100KA, LARM, incremental handwheel

Cat. no.: IRC536/100KA

IRC536/100KA LARM – incremental handwheel. Industrial product for automation, measurement and control.

On request
228,26 €
excl. VAT · 276,20 € incl. VAT

IRC302/1000KB, LARM, incremental rotary encoder

Cat. no.: IRC302/1000KB

IRC302/1000KB LARM – incremental rotary encoder, PNP. Industrial product for automation, measurement and control.

On request
232,30 €
excl. VAT · 281,09 € incl. VAT

LS501-10P/1250/R5k L0.25%/KB, LARM, draw-wire encoder, IP65

Cat. no.: LS501-10P/1250/R5k L0,25%/KB

LS501-10P/1250/R5k L0.25%/KB, LARM, draw-wire encoder, IP65. Incremental encoder for precise position or speed measurement. Parameters at Technoline.cz.

On request
236,41 €
excl. VAT · 286,05 € incl. VAT

IRC315/6000KB, LARM, incremental rotary encoder

Cat. no.: IRC315/6000KB

IRC315/6000KB LARM – incremental rotary encoder. Industrial product for automation, measurement and control.

On request
242,01 €
excl. VAT · 292,83 € incl. VAT

IRC325/5000KBB, LARM, incremental rotary encoder

Cat. no.: IRC325/5000KBB

IRC325/5000KBB LARM – incremental rotary encoder. Industrial product for automation, measurement and control.

On request
247,58 €
excl. VAT · 299,57 € incl. VAT

IRC310/5000KB, LARM, incremental rotary encoder

Cat. no.: IRC310/5000KB

IRC310/5000KB LARM – incremental rotary encoder, push/pull. Industrial product for automation, measurement and control.

On request
265,22 €
excl. VAT · 320,91 € incl. VAT

ARC410/10KA, LARM, absolute rotary encoder

Cat. no.: ARC410/10KA

ARC410/10KA LARM – absolute rotary encoder. Industrial product for automation, measurement and control.

On request
296,37 €
excl. VAT · 358,61 € incl. VAT

Prices include the recycling fee.

Incremental Encoders

An incremental encoder converts movement into increments that the evaluation device counts. When designing position, length or speed measurement, you therefore choose the encoder, the mechanical transmission and the control system input together. The number of pulses per revolution alone is not enough: the signal speed, electrical wiring and method of determining the home position must also be suitable.

The catalogue under this branch also groups absolute and draw-wire versions. However, incremental and absolute denote different methods of transmitting position; draw-wire denotes the mechanical arrangement. Therefore do not use the category name as a substitute for data on the actual output of a specific product.

First decide what you need to measure

  • For a change in angle or shaft speed, choose in the category Incremental rotary encoders. Determine the ratio between the measured movement and the encoder shaft.
  • For a position value after switching on, study Absolute encoders. The exact catalogue name combines two different principles; for a product, its documentation is decisive.
  • For converting linear movement using a wound wire, use Draw-wire incremental encoders. Depending on the version, the output can be incremental or, for example, potentiometric.
  • Address the mechanical connection at the same time as selecting the encoder. The category that will help is Incremental encoder accessories.

How to read the A, B and Z signals

The A/B pair in quadrature design has a mutual offset of 90 electrical degrees. The order of changes makes it possible to recognise the direction of movement. This is a quarter of the signal period, not a quarter turn of the shaft. Verify the positive direction according to the view of the shaft, wiring and counter settings; the terminal names alone do not determine the direction of machine movement.

Channel Z, also called the index or zero pulse, provides a reference mark. On a conventional rotary version it appears once per revolution; verify its presence, width and relation to A/B for the specific type. The inverted signals A−, B− and possibly Z− are not additional measuring axes. In differential transmission, they complement the corresponding positive signals.

Resolution, accuracy and edge evaluation

Resolution expresses the smallest distinguishable step. Accuracy describes the relationship of the result to the actual position and repeatability the scatter of repeated measurements under the same conditions. A finer step alone does not remove backlash in the transmission, slip of the measuring wheel or mounting error. Therefore convert the requirement "measure to a tenth of a millimetre" separately into the step size and the permissible error of the entire assembly.

Let N denote the number of complete periods of channel A per revolution. The abbreviations PPR and CPR do not have the same meaning for all manufacturers, so verify their definition. For a quadrature counter:

  • ×1 evaluation produces one increment per period, i.e. N increments per revolution.
  • ×2 evaluation uses both edges of one channel, i.e. 2N increments.
  • ×4 evaluation uses both edges of A and B, i.e. 4N increments.

The selected mode must match the conversion in the program. At ×4, the ideal angular step is 360°/(4N). Some function blocks perform the conversion themselves; multiplying again in the program would distort the result.

Technical document: NI: ×1, ×2 and ×4 evaluation.

Channel frequency is not the rate of all edges

At a speed n in revolutions per minute, each A/B channel has a frequency f = N × n / 60 in hertz. With ×4 evaluation, the counter processes a total of 4f increments per second. This does not mean that each channel has four times the frequency. Input documentation may state the limit in periods per second or in increments per second; unify the meaning of the data before comparing.

Technical document: Beckhoff: frequency and increment rate.

Own checking procedure: calculate the frequency at the highest actual speed, compare it with the output limit of the encoder and then with the input limit for the selected mode. Separately verify the minimum length of the Z pulse and the input filter setting. The mechanical speed limit does not replace the electrical limit. A conventional cyclically read PLC input cannot be used instead of a fast counter without verification.

Model example: conveyor measuring wheel

Consider an ideal wheel circumference of 200 mm, a direct connection to the encoder N = 1 000 periods/revolution and a belt speed of 1 m/s without slip. The wheel makes 5 revolutions per second, i.e. 300 rpm. Each channel has a frequency of 5 kHz; at ×4 the counter processes 20 000 increments per second. The calculated length step is 200/4 000 = 0.05 mm.

This result is not a promise of accuracy for a specific product. For your own test, compare the reading over a known length at slow and fast feed and in both directions. A constant proportional deviation suggests checking the circumference and scale; a speed-dependent deviation suggests checking the signal and slip. This is a diagnostic guide, not an unambiguous determination of the fault.

TTL, HTL and RS422: compare the output with the input

TTL denotes logic levels commonly associated with 5V signals. HTL is used for higher levels in industrial encoders, often derived from the supply. RS422 describes a differential electrical interface. The designation TTL/RS422 can therefore appear together; these are not three mutually interchangeable connectors. The exact voltage limits are determined by the datasheet.

Technical document: Baumer: example of an HTL and TTL/RS422 specification (PDF).

Do not confuse the supply voltage of the encoder with its output level. Check the supply, receiver input thresholds, permitted current, reference potential, differential pairs and any line termination. Do not connect an HTL output directly to a pure 5V input. An NPN/PNP open collector also cannot automatically be considered push-pull; the required load wiring depends on both devices.

Homing and return to operation

Incremental pulses alone do not contain an unambiguous absolute coordinate. After the counted position is lost, the system needs homing or another documented method of restoring it. One procedure is to find the area with a reference switch and then capture the index Z. An index repeated every revolution does not itself tell which revolution of a multi-turn movement the machine is in.

When designing acceptance, therefore also check restart: will the coordinate remain valid if the mechanism moves while evaluation is switched off? The stored counter value alone does not solve this situation. Also check the relation of the reference to the working range of the machine and the repeatability of returning to the same mark.

Frequently asked questions when choosing

Is an identical connector enough for a replacement?

No. Prepare a comparison of pins, levels, supply, number of periods, reference, shaft and flange. Add space for the cable outlet and the permissible shaft load. An identical appearance is not proof of functional interchangeability.

Is the highest available resolution always an advantage?

Choose according to the required step and achievable measurement error. A higher number of periods increases the demands on transmission at the same speed. A practical order specification therefore also includes the maximum speed, input type, evaluation mode, environment and the required behaviour after switching on.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.