Phone +420 774 723 123 Cart · 0 · empty

Individual modules and accessories

Individual modules and accessories for EMAS 50 mm IP65 beacons for assembling or repairing the beacon.

Filters
Found 5 products

IKM5KE, EMAS, 50 mm signal module, red, 24V DC, 50 mm, IP65

Cat. no.: IKM5KE

IKM5KE EMAS - signal module 50 mm, red, 24V DC, 50 mm, IP65. Technical specifications, use, installation and selection of the correct variant.

On request
16,99 €
excl. VAT · 20,56 € incl. VAT

IKM5YE, EMAS, signal module 50 mm, green, 24V DC, 50 mm, IP65

Cat. no.: IKM5YE

IKM5YE EMAS - signal module 50 mm, green, 24V DC, 50 mm, IP65. Technical specifications, use, installation and selection of the correct variant.

On request
16,99 €
excl. VAT · 20,56 € incl. VAT

IKM5RE, EMAS, 50 mm signal module, yellow, 24V DC, 50 mm, IP65

Cat. no.: IKM5RE

IKM5RE EMAS - 50 mm signalling module, yellow, 24V DC, 50 mm, IP65. Technical specifications, use, installation and selection of the correct variant.

On request
16,99 €
excl. VAT · 20,56 € incl. VAT

IKM5BE, EMAS, 50 mm signal module, white, 24V DC, 50 mm, IP65

Cat. no.: IKM5BE

IKM5BE EMAS - 50 mm signal module, white, 24V DC, 50 mm, IP65. Technical specifications, use, installation and selection of the correct variant.

On request
16,99 €
excl. VAT · 20,56 € incl. VAT

IKM5ME, EMAS, 50 mm signal module, blue, 24V DC, 50 mm, IP65

Cat. no.: IKM5ME

IKM5ME EMAS - 50 mm signal module, blue, 24V DC, 50 mm, IP65. Technical specifications, use, installation and selection of the correct variant.

On request
16,99 €
excl. VAT · 20,56 € incl. VAT

Prices include the recycling fee.

Individual modules and accessories

When servicing a lamp from the IP65 branch, you need to determine not only the color of the replacement part, but also its construction. In the catalog, for example, there are white IKM5BE and blue IKM5ME modules without LED bulbs. The optical module, light source, and base perform different tasks; distinguish them in the service order.

Base and optical part

EMAS Catalogue denotes IKM5G as a body with a 50 mm diameter cap.

When replacing the base, request confirmation that the specific construction being supplied matches the repaired column. The same code in the list does not yet describe all installation conditions. Compare the mounting points, the closure of the upper part, and the cable routing. Do not return a damaged or unidentifiable part simply because it can be fitted with an additional layer.

In the overview Economic beacons - diameter 50mm EMAS (IP65) Check the continuity with the original construction. Do not omit the letter E when ordering if it is part of the identification of the smaller module. When replacing a visually similar part from another branch, specify the details, do not generalize from the same diameter.

Repair procedure

  1. After safe disconnection, record the order of the modules and the full marking of all changed components. Before handling remove impurities from the vicinity of the joints.
  2. Check the contact areas, contacts and elements that close the individual parts. See if any of the adjacent parts affected the impact or leak.
  3. Identify separately the embedded light source. In category LED bulbs up to 50mm and 70mm beacons Emas verify the voltage, cap and light function of the specific replacement.
  4. Close the assembly according to its assembly instructions. Enter in the service record the codes exchanged and the result of the functional check of all floors.

Do not add tight-fitting material or new openings without a foundation for the given construction. Such an action changes the conditions of the original construction. Lighting all floors after repair confirms the electrical function, but does not prove the restored cover.

Model example: White module exchange

Consider a column with a burnt white segment marked IKM5BE. Maintenance compares the replacement part with the original and checks the neighboring contacts and closing parts. The source orders separately only if a replacement is also needed. After installation, verify the response to the relevant command and record the action. When the origin of other parts is unclear, compare the repair with the specified replacement. Compound beacons.

Frequently asked questions

Can I add a horn and leave the same cover?

This cannot be confirmed without proof of the resulting configuration. The production catalogue for the IP65 version provides an exception for the horn.

Just keep the original LED bulb?

Only if it complies with voltage, function and mechanical execution and has not been damaged. Consider the cause of the original defect so that it does not repeat after repair.

Is a fixed beacon a safety device?

No. It continues to be used for operational information. The service of individual modules does not add safety function.

Cookies on this website