6EP3436-8SB00-4AY0, Siemens SITOP PSU8400 – regulated power supply 24 V DC / 20 A, IO-Link

Cat. no.: 6EP3436-8SB00-4AY0

6EP3436-8SB00-4AY0 Siemens SITOP PSU8400 is a regulated power supply with an output of 24 V DC / 20 A and a version for three-phase AC input. Designed for production lines, control cabinets and…

On request
277,70 €
excl. VAT · 336,02 € incl. VAT

6EP1536-3AA00, Siemens SITOP PSU400M – DC/DC converter 600 V DC → 24 V DC / 20 A

Cat. no.: 6EP1536-3AA00

6EP1536-3AA00 Siemens SITOP PSU400M is an industrial DC/DC converter converting 600 V DC to 24 V DC / 20 A. Designed for machines and control cabinets where the available DC voltage needs to be…

On request
295,96 €
excl. VAT · 358,11 € incl. VAT

6EP1437-2BA20, Siemens SITOP PSU300S – regulated power supply 24 V DC / 40 A

Cat. no.: 6EP1437-2BA20

6EP1437-2BA20 Siemens SITOP PSU300S is a regulated power supply with an output of 24 V DC / 40 A and a version for three-phase AC input. Designed for standard to more demanding machines and control…

On request
298,97 €
excl. VAT · 361,75 € incl. VAT

6EP3437-8SB00-0AY0, Siemens SITOP PSU8200 – regulated power supply 24 V DC / 40 A

Cat. no.: 6EP3437-8SB00-0AY0

6EP3437-8SB00-0AY0 Siemens SITOP PSU8200 is a regulated power supply with an output of 24 V DC / 40 A and a version for three-phase AC input. Designed for PLCs, HMIs, sensors, actuators and other…

On request
323,82 €
excl. VAT · 391,82 € incl. VAT

6EP3436-7SC00-3AX0, Siemens SITOP PSU6200 – regulated power supply 24 V DC / 20 A, Ex

Cat. no.: 6EP3436-7SC00-3AX0

6EP3436-7SC00-3AX0 Siemens SITOP PSU6200 is a regulated power supply with an output of 24 V DC / 20 A and a version for three-phase AC input. Designed for automation control cabinets, PLCs…

On request
328,86 €
excl. VAT · 397,92 € incl. VAT

6EP1334-7CA10, Siemens SITOP PSU100P – regulated power supply 24 V DC / 8 A, IP67

Cat. no.: 6EP1334-7CA10

6EP1334-7CA10 Siemens SITOP PSU100P is a regulated power supply with an output of 24 V DC / 8 A and a version for single-phase AC input. Designed for installations directly at the machine outside a…

On request
328,85 €
excl. VAT · 397,91 € incl. VAT

6EP3437-8UB00-0AY0, Siemens SITOP PSU3800 – charging power supply 24 V DC / 30–40 A

Cat. no.: 6EP3437-8UB00-0AY0

6EP3437-8UB00-0AY0 Siemens SITOP PSU3800 is a charging power supply with an output of 24 V DC / 30–40 A and a version for three-phase AC input. Designed for industrial DC systems with a battery where…

On request
336,24 €
excl. VAT · 406,85 € incl. VAT

6EP3336-7SC00-3AX0, Siemens SITOP PSU6200 – regulated power supply 24 V DC / 20 A, Ex

Cat. no.: 6EP3336-7SC00-3AX0

6EP3336-7SC00-3AX0 Siemens SITOP PSU6200 is a regulated power supply with an output of 24 V DC / 20 A and a version for single-phase AC input. Designed for automation control cabinets, PLCs…

On request
344,20 €
excl. VAT · 416,48 € incl. VAT

6EP3337-8SB00-0AY0, Siemens SITOP PSU8200 – regulated power supply 24 V DC / 40 A

Cat. no.: 6EP3337-8SB00-0AY0

6EP3337-8SB00-0AY0 Siemens SITOP PSU8200 is a regulated power supply with an output of 24 V DC / 40 A and a version for single-phase AC input. Designed for PLCs, HMIs, sensors, actuators and other…

On request
362,53 €
excl. VAT · 438,67 € incl. VAT

6EP3437-8SB00-4AY0, Siemens SITOP PSU8400 – regulated power supply 24 V DC / 40 A, IO-Link

Cat. no.: 6EP3437-8SB00-4AY0

6EP3437-8SB00-4AY0 Siemens SITOP PSU8400 is a regulated power supply with an output of 24 V DC / 40 A and a version for three-phase AC input. Designed for production lines, control cabinets and…

On request
369,06 €
excl. VAT · 446,56 € incl. VAT

6EP3436-8SB00-2AY0, Siemens SITOP PSU8600 – regulated power supply 24 V DC / 20 A, PROFINET

Cat. no.: 6EP3436-8SB00-2AY0

6EP3436-8SB00-2AY0 Siemens SITOP PSU8600 is a regulated power supply with an output of 24 V DC / 20 A and a version for three-phase AC input. Designed for machines with higher requirements for…

On request
383,67 €
excl. VAT · 464,24 € incl. VAT

6EP3447-8SB00-0AY0, Siemens SITOP PSU8200 – regulated power supply 48 V DC / 20 A

Cat. no.: 6EP3447-8SB00-0AY0

6EP3447-8SB00-0AY0 Siemens SITOP PSU8200 is a regulated power supply with an output of 48 V DC / 20 A and a version for three-phase AC input. Designed for PLCs, HMIs, sensors, actuators and other…

On request
386,65 €
excl. VAT · 467,84 € incl. VAT

6EP3437-7SC00-3AX0, Siemens SITOP PSU6200 – regulated power supply 24 V DC / 40 A, Ex

Cat. no.: 6EP3437-7SC00-3AX0

6EP3437-7SC00-3AX0 Siemens SITOP PSU6200 is a regulated power supply with an output of 24 V DC / 40 A and a version for three-phase AC input. Designed for automation control cabinets, PLCs…

On request
439,19 €
excl. VAT · 531,42 € incl. VAT

6ES7148-4PC00-0HA0, Siemens SIMATIC ET 200pro PS – regulated power supply 24 V DC / 8 A, IP67

Cat. no.: 6ES7148-4PC00-0HA0

6ES7148-4PC00-0HA0 Siemens SIMATIC ET 200pro PS is a regulated power supply with an output of 24 V DC / 8 A and a version for three-phase AC input. Designed for decentralised automation and…

On request
449,47 €
excl. VAT · 543,86 € incl. VAT

6EP3337-8SC00-0AY0, Siemens SITOP PSU8200 – regulated power supply 24 V DC / 40 A, Ex

Cat. no.: 6EP3337-8SC00-0AY0

6EP3337-8SC00-0AY0 Siemens SITOP PSU8200 is a regulated power supply with an output of 24 V DC / 40 A and a version for single-phase AC input. Designed for PLCs, HMIs, sensors, actuators and other…

On request
480,17 €
excl. VAT · 581,01 € incl. VAT

6EP3437-8SB00-2AY0, Siemens SITOP PSU8600 – regulated power supply 24 V DC / 40 A, PROFINET

Cat. no.: 6EP3437-8SB00-2AY0

6EP3437-8SB00-2AY0 Siemens SITOP PSU8600 is a regulated power supply with an output of 24 V DC / 40 A and a version for three-phase AC input. Designed for machines with higher requirements for…

On request
489,65 €
excl. VAT · 592,48 € incl. VAT

6EP3436-8MB00-2CY0, Siemens SITOP PSU8600 – regulated power supply 24 V DC / 20 A, PROFINET

Cat. no.: 6EP3436-8MB00-2CY0

6EP3436-8MB00-2CY0 Siemens SITOP PSU8600 is a regulated power supply with an output of 24 V DC / 20 A and a version for three-phase AC input. Designed for machines with higher requirements for…

On request
489,62 €
excl. VAT · 592,44 € incl. VAT

6EP3336-8MB00-2CY0, Siemens SITOP PSU8600 – regulated power supply 24 V DC / 20 A, PROFINET

Cat. no.: 6EP3336-8MB00-2CY0

6EP3336-8MB00-2CY0 Siemens SITOP PSU8600 is a regulated power supply with an output of 24 V DC / 20 A and a version for single-phase / two-phase AC input. Designed for machines with higher…

On request
553,20 €
excl. VAT · 669,37 € incl. VAT

6EP3437-8MB00-2CY0, Siemens SITOP PSU8600 – regulated power supply 24 V DC / 40 A, PROFINET

Cat. no.: 6EP3437-8MB00-2CY0

6EP3437-8MB00-2CY0 Siemens SITOP PSU8600 is a regulated power supply with an output of 24 V DC / 40 A and a version for three-phase AC input. Designed for machines with higher requirements for…

On request
624,82 €
excl. VAT · 756,04 € incl. VAT

Prices include the recycling fee.

Siemens power supplies

This branch is not limited to a single voltage or design series. Catalogue items include, for example, 6EP3331-6SB00-0AY0, 6EP1333-1LB00, 6EP1436-2BA10 and 6EP3311-6SB00-0AY0 for 5 V DC. When selecting, distinguish the complete order code: a similar beginning of the name does not confirm the same mains supply or mounting.

Output voltage and type of supply

A regulated power supply converts the input to the required DC voltage. However, belonging to Siemens alone does not mean that it is a power module for every PLC system. Verify whether the equipment needs an external supply or a system power supply designed for a specific bus.

For 6EP1436-2BA10, the manufacturer states a three-phase rated input of 400–500 V AC and an output of 24 V DC, 20 A; see the Siemens data sheet. These data cannot be transferred to smaller power supplies with the same output voltage. Changing the mains supply is a substantial design change, not just a replacement with higher power.

Power applies under specified conditions

The LOGO!Power manual states the load conditions by type and points out the current limitation when the output voltage is increased. Data sheet 6EP3331-6SB00-0AY0 specifies a derating of 2 % per kelvin at an ambient temperature of +55 to +70 °C. This is not a common characteristic of all Siemens power supplies.

When checking the installation, start from the correct drawing: support rail or mounting surface, dimensions, clearances and space at the terminals. The same power does not mean the same fixing. Before mechanical replacement, confirm the specific version and the necessary mounting accessories. Also include the cabling in the used depth of the enclosure; the dimension of the metal or plastic housing alone is not enough.

Model example of separate voltage branches

Assume a load of 5 V / 2 A and another load of 24 V / 1 A. The total useful power is 10 + 24 = 34 W, but this sum does not mean that both devices can be connected to a single 24V output. A separate suitable branch or a correctly designed DC/DC converter is needed. The figures are model values, not a recommendation of a specific Siemens assembly.

With an assumed converter efficiency of 90 %, the 10W branch requires approximately 11.1 W at the input, i.e. 0.46 A at 24 V. A common 24V power supply would thus supply approximately 1.46 A continuously, even before assessing start-up and derating. Counting only the original 34 W would neglect the conversion loss. Also assess the required separation of the individual circuits.

Frequently asked questions and mistakes when replacing

Are the same 24 V and more amps enough?

No. Check the network type, protection and inrush current, overload behaviour, required SELV/PELV and mounting. The connected conductors and terminals have their own current capacity, which a stronger power supply will not increase.

Can I eliminate the voltage drop on a long cable by increasing the voltage?

Only after verifying all loads, the permissible setting and the power limit. First recalculate the wiring; a nearby load may be exposed to a higher voltage than a distant one. The general procedure and the distinction between continuous consumption and peaks are given in the guide Power supplies.