Power Supplies

Power supplies for automation, control cabinets and machines – 5, 12, 24 and 48 V DC switched-mode supplies for DIN rail and panel mounting from MEAN WELL, Siemens, Omron, Balluff, IDEC and others. Choose by output voltage and current with reserve, supply network, dimensions and operating temperature.

Podkategorie

Filtry
Znaleziono 330 produktów

6EP3233-0TA00-0AY0, Siemens SITOP PSU3400 – DC/DC converter 48 V DC → 24 V DC / 5 A

Nr kat.: 6EP3233-0TA00-0AY0

6EP3233-0TA00-0AY0 Siemens SITOP PSU3400 is an industrial DC/DC converter converting 48 V DC to 24 V DC / 5 A. Designed for machines and control cabinets where the available DC voltage needs to be…

Na zapytanie
128,85 €
bez VAT · 155,90 € z VAT

6EP1433-2BA20, Siemens SITOP PSU300S – regulated power supply 24 V DC / 5 A

Nr kat.: 6EP1433-2BA20

6EP1433-2BA20 Siemens SITOP PSU300S is a regulated power supply with an output of 24 V DC / 5 A and a version for three-phase AC input. Designed for standard to more demanding machines and control…

Na zapytanie
129,58 €
bez VAT · 156,80 € z VAT

6EP1322-2BA00, Siemens SITOP PSU100S – regulated power supply 12 V DC / 7 A

Nr kat.: 6EP1322-2BA00

6EP1322-2BA00 Siemens SITOP PSU100S is a regulated power supply with an output of 12 V DC / 7 A and a version for single-phase AC input. Designed for standard to more demanding machines and control…

Na zapytanie
134,71 €
bez VAT · 162,99 € z VAT

6EP3433-7SB00-0AX0, Siemens SITOP PSU6200 – regulated power supply 24 V DC / 5 A

Nr kat.: 6EP3433-7SB00-0AX0

6EP3433-7SB00-0AX0 Siemens SITOP PSU6200 is a regulated power supply with an output of 24 V DC / 5 A and a version for three-phase AC input. Designed for automation control cabinets, PLCs…

Na zapytanie
136,18 €
bez VAT · 164,78 € z VAT

6EP1333-3BA10, Siemens SITOP PSU200M – regulated power supply 24 V DC / 5 A

Nr kat.: 6EP1333-3BA10

6EP1333-3BA10 Siemens SITOP PSU200M is a regulated power supply with an output of 24 V DC / 5 A and a version for single-phase / two-phase AC input. Designed for PLCs, HMIs, sensors, actuators and…

Na zapytanie
137,64 €
bez VAT · 166,55 € z VAT

6EP3233-0TA10-0AY0, Siemens SITOP PSU3400 – DC/DC converter 48 V DC → 24 V DC / 3.5 A

Nr kat.: 6EP3233-0TA10-0AY0

6EP3233-0TA10-0AY0 Siemens SITOP PSU3400 is an industrial DC/DC converter converting 48 V DC to 24 V DC / 3.5 A. Designed for machines and control cabinets where the available DC voltage needs to be…

Na zapytanie
139,83 €
bez VAT · 169,19 € z VAT

S8FS-C35012 OMRON – power supply S8FS-C, 350 W, 12 V DC / 29 A

Nr kat.: S8FS-C35012

S8FS-C35012 OMRON is an industrial power supply of the S8FS-C. series with a power of 350 W, an output of 12 V DC and a rated current of 29 A. Version: Built-in / direct mounting. Supply / phase: 1f…

Na zapytanie
145,90 €
bez VAT · 176,54 € z VAT

S8FS-C35024 OMRON – power supply S8FS-C, 350 W, 24 V DC / 14.6 A

Nr kat.: S8FS-C35024

S8FS-C35024 OMRON is an industrial power supply of the S8FS-C. series with a power of 350 W, an output of 24 V DC and a rated current of 14.6 A. Version: Built-in / direct mounting. Supply / phase…

Na zapytanie
145,90 €
bez VAT · 176,54 € z VAT

S8FS-C35024J OMRON – power supply S8FS-C, 350 W, 24 V DC / 14.6 A

Nr kat.: S8FS-C35024J

S8FS-C35024J OMRON is an industrial power supply of the S8FS-C. series with a power of 350 W, an output of 24 V DC and a rated current of 14.6 A. Version: Built-in / direct mounting. Supply / phase…

Na zapytanie
145,90 €
bez VAT · 176,54 € z VAT

6EP1334-2BA20, Siemens SITOP PSU100S – regulated power supply 24 V DC / 10 A

Nr kat.: 6EP1334-2BA20

6EP1334-2BA20 Siemens SITOP PSU100S is a regulated power supply with an output of 24 V DC / 10 A and a version for single-phase AC input. Designed for standard to more demanding machines and control…

Na zapytanie
150,09 €
bez VAT · 181,61 € z VAT

6EP1434-2BA20, Siemens, SITOP PSU300S, three-phase regulated power supply 24VDC/10A, 240W

Nr kat.: 6EP1434-2BA20

6EP1434-2BA20, Siemens, SITOP PSU300S, three-phase regulated power supply 24VDC/10A, 240W. The three-phase input 400–500VAC and the regulated output 24VDC/10A are decisive for replacing the power…

Na zapytanie
152,38 €
bez VAT · 184,38 € z VAT
NASZA PORADA

BAE00LJ, BALLUFF, power supply 24VDC/10A, 240W, IO-Link, DIN rail

Nr kat.: BAE00LJ

BAE00LJ BALLUFF is an industrial power supply 24VDC/10A with a power of 240W. Version: IO-Link, IP20, DIN rail. Suitable for industrial automation, machines and control cabinets.

Na zapytanie
152,68 €
bez VAT · 184,74 € z VAT
NASZA PORADA

BAE00LJ, BALLUFF, power supply 24VDC/10A, 240W, IO-Link, DIN rail

Nr kat.: BAE00LJ

BAE00LJ BALLUFF is an industrial power supply 24VDC/10A with a power of 240W. Version: IO-Link, IP20, DIN rail. Suitable for industrial automation, machines and control cabinets.

Na zapytanie
152,68 €
bez VAT · 184,74 € z VAT

S8VK-G12024 OMRON – power supply S8VK-G, 120 W, 24 V DC / 5 A

Nr kat.: S8VK-G12024

S8VK-G12024 OMRON is an industrial power supply of the S8VK-G. series with a power of 120 W, an output of 24 V DC and a rated current of 5 A. Version: Pro, DIN rail. Supply / phase: 1f. Connection…

Na zapytanie
152,96 €
bez VAT · 185,08 € z VAT

6EP3333-7SC00-0AX0, Siemens SITOP PSU6200 – regulated power supply 24 V DC / 5 A, Ex

Nr kat.: 6EP3333-7SC00-0AX0

6EP3333-7SC00-0AX0 Siemens SITOP PSU6200 is a regulated power supply with an output of 24 V DC / 5 A and a version for single-phase AC input. Designed for automation control cabinets, PLCs…

Na zapytanie
155,95 €
bez VAT · 188,69 € z VAT

6EP3332-0TA00-0AY0, Siemens SITOP PSU3400 uni – DC/DC converter 24 V DC / 230 V AC → 24 V DC / 2.5 A

Nr kat.: 6EP3332-0TA00-0AY0

6EP3332-0TA00-0AY0 Siemens SITOP PSU3400 uni is an industrial DC/DC converter converting 24 V DC / 230 V AC to 24 V DC / 2.5 A. Designed for machines and control cabinets where the available DC…

Na zapytanie
158,86 €
bez VAT · 192,22 € z VAT

S8VK-S12024 OMRON – power supply S8VK-S, 120 W, 24 V DC / 5 A

Nr kat.: S8VK-S12024

S8VK-S12024 OMRON is an industrial power supply of the S8VK-S. series with a power of 120 W, an output of 24 V DC and a rated current of 5 A. Version: DIN, coated. Supply / phase: 1f. Connection…

Na zapytanie
159,70 €
bez VAT · 193,24 € z VAT

6EP3334-8SB00-0AY0, Siemens SITOP PSU8200 – regulated power supply 24 V DC / 10 A

Nr kat.: 6EP3334-8SB00-0AY0

6EP3334-8SB00-0AY0 Siemens SITOP PSU8200 is a regulated power supply with an output of 24 V DC / 10 A and a version for single-phase AC input. Designed for PLCs, HMIs, sensors, actuators and other…

Na zapytanie
161,81 €
bez VAT · 195,80 € z VAT

SDR-480-24, Mean Well, switched-mode DIN-rail power supply, 24VDC/20A, 480W

Nr kat.: SDR-480-24

SDR-480-24 Mean Well – switched-mode power supply of the SDR-480 series for DIN rail, 480W, 24VDC/20A, input 90–264VAC. Suitable for industrial control cabinets, PLCs, HMIs, sensors, relays and other…

Na zapytanie
165,32 €
bez VAT · 200,03 € z VAT

SDR-480-48, Mean Well, switched-mode DIN-rail power supply, 48VDC/10A, 480W

Nr kat.: SDR-480-48

SDR-480-48 Mean Well – switched-mode power supply of the SDR-480 series for DIN rail, 480W, 48VDC/10A, input 90–264VAC. Suitable for industrial control cabinets, PLCs, HMIs, sensors, relays and other…

Na zapytanie
165,32 €
bez VAT · 200,03 € z VAT

SDR-480P-48, Mean Well, switched-mode DIN-rail power supply, 48VDC/10A, 480W

Nr kat.: SDR-480P-48

SDR-480P-48 Mean Well – switched-mode power supply of the SDR-480P series for DIN rail, 480W, 48VDC/10A, input 90–264VAC. Suitable for industrial control cabinets, PLCs, HMIs, sensors, relays and…

Na zapytanie
165,32 €
bez VAT · 200,03 € z VAT

SDR-480P-24, Mean Well, switched-mode DIN-rail power supply, 24VDC/20A, 480W

Nr kat.: SDR-480P-24

SDR-480P-24 Mean Well – switched-mode power supply of the SDR-480P series for DIN rail, 480W, 24VDC/20A, input 90–264VAC. Suitable for industrial control cabinets, PLCs, HMIs, sensors, relays and…

Na zapytanie
166,08 €
bez VAT · 200,95 € z VAT

6EP3436-3SB00-0AX0, Siemens SITOP PSU4200 – regulated power supply 24 V DC / 20 A

Nr kat.: 6EP3436-3SB00-0AX0

6EP3436-3SB00-0AX0 Siemens SITOP PSU4200 is a regulated power supply with an output of 24 V DC / 20 A and a version for three-phase AC input. Designed for series machines, control cabinets, PLCs and…

Na zapytanie
166,26 €
bez VAT · 201,18 € z VAT

S8VK-C24024 OMRON – power supply S8VK-C, 240 W, 24 V DC / 10 A

Nr kat.: S8VK-C24024

S8VK-C24024 OMRON is an industrial power supply of the S8VK-C. series with a power of 240 W, an output of 24 V DC and a rated current of 10 A. Version: Lite, DIN rail. Supply / phase: 1f. Connection…

Na zapytanie
167,66 €
bez VAT · 202,86 € z VAT

6EP3434-7SB00-3AX0, Siemens SITOP PSU6200 – regulated power supply 24 V DC / 10 A

Nr kat.: 6EP3434-7SB00-3AX0

6EP3434-7SB00-3AX0 Siemens SITOP PSU6200 is a regulated power supply with an output of 24 V DC / 10 A and a version for three-phase AC input. Designed for automation control cabinets, PLCs…

Na zapytanie
168,40 €
bez VAT · 203,76 € z VAT

Ceny zawierają opłatę recyklingową.

Power supplies

Choose a power supply as part of the entire supply circuit: from the mains feed through the control cabinet to the terminals of the most distant load. The correct output voltage is the first condition, not full confirmation of compatibility. The current during normal operation and start-up, the temperature inside the enclosure, protection, mounting method and the requirements of the connected equipment for protective separation are also decisive.

What this branch includes

The catalogue divides the range into the categories Allen-Bradley power supplies, IDEC 5/12/24V DC power supplies, CHINFA 12/24V DC power supplies, PULS 24V DC power supplies, Rievtech power supplies and Siemens power supplies. Catalogue items include, for example, CHINFA DRS1-24A and DRS5-24A, PULS PIC120.241C, Rievtech RPS-60-24 and several Siemens order codes. The parameters of these products are not common parameters of the whole category. The existence of the branch also does not confirm the availability of a specific type.

How a switched-mode regulated power supply works

A switched-mode power supply converts input energy using a rapidly switched power circuit; feedback adjusts the operation so that the output holds the required voltage within the permitted limits. Output filtering limits ripple but does not eliminate all transients. The basic difference from a linear power supply is described in the IDEC technical FAQ. For sensitive analogue measurement, therefore check not only the rated voltage but also the ripple, permissible interference and the routing of common return conductors.

Continuous load, simultaneity and peaks

List all loads by voltage branch. For each, record the highest operating current, short-term consumption, its duration and when it occurs. Do not calculate the coil current from the current capacity of its contacts; the figure on a relay output is not the relay's consumption. For equipment with externally powered outputs, check whether the documented consumption also includes the connected loads. Do not count the same current twice.

The required continuous current is determined by the worst permissible simultaneous operation, not by the average over a shift. Compare the peak with the overload characteristic of the selected power supply, including its duration and repetition. The boost designation alone is not enough. Design the reserve according to expansion and actual operating uncertainties; a universal percentage does not replace assessment of the start-up.

Model example of a current balance

Consider a hypothetical 24 V branch: the controller draws 0.45 A, the panel 0.35 A, eight sensors 0.03 A each and four simultaneously energised coils 0.12 A each. The sum is 1.52 A, i.e. 36.48 W. If the panel needs 1.10 A instead of 0.35 A at switch-on for 80 ms, the simultaneous consumption rises to 2.27 A. These are chosen inputs for the example, not data of the devices offered.

A power supply with a rated current of 2 A cannot be approved from the first sum alone, nor automatically rejected from the second: the permissible time characteristic and the voltage drop will decide. If we do not know it, we do not assume a short-term reserve. Delaying some loads can only help if their sequence is also ensured after the power supply is restored.

Derating, losses and space in the control cabinet

Derating means reducing the permissible load under specified conditions. It may relate to ambient temperature, altitude or a different mounting position; the curve of the specific type is decisive, as explained in the PULS guide to derating. The upper operating temperature is not automatically the temperature for full power. Assess the air at the power supply, not just the room temperature.

Your own design check should include the width on the rail, the depth including terminals, conductor bending and the prescribed ventilation clearances. Losses also belong in the heat balance. As a model, with an output of 100 W and an assumed efficiency of 90 %, approximately 11.1 W of heat is generated: 100 / 0.90 − 100. However, determine the efficiency of the chosen product for the actual load. Free space above the device does not replace verification of airflow in the enclosure.

Input inrush current and protection

AC inrush is a short input current when charging capacitors after connection to the mains. It is not the same as the starting current of a load on the DC output. The cause and methods of limiting it are described in the PULS documentation on inrush current. When several power supplies are switched on together, check the entire feed, the switching element and the manufacturer's recommendations. The ratio of output watts to mains voltage alone is not enough to choose a circuit breaker.

On the output, coordinate the protection of the individual branches with the current limiting of the power supply and the resistance of the wiring. The power supply may limit the current before an ordinary circuit breaker trips quickly; this relationship is discussed in PULS: protection of DC circuits. The specific solution must suit the cabling, load and required selectivity. The internal protection of the power supply does not automatically replace the protection of every branch.

SELV and PELV are not designations of 24 V

Both extra-low-voltage protective systems require appropriate protective separation from higher-voltage circuits. SELV maintains separation from earth; PELV allows earthing according to the protection design. The difference is explained in Schneider Electric documentation on SELV and the relationship between SELV and PELV. Connecting the protective conductor to the chassis of the power supply is not the same as connecting the negative output to earth.

Assess suitability for the whole circuit, including connections to other devices. 24 V alone, a plastic housing or the general brand of the manufacturer do not prove SELV or PELV. The equipment requirements, specific documents and earthing method must match.

Voltage at the load and verification procedure

Also check the voltage at the load at maximum consumption. As a model, a total loop resistance of 0.4 Ω at 1.5 A creates a drop of 0.6 V. By increasing the supply voltage you may overload nearby devices; first assess the conductors, length and distribution of branches.

  1. Verify the input network, number of phases, output voltage and polarity.
  2. Compare the current balance with the permissible load after derating and with the start-up.
  3. Check the mounting, terminals, protective connection and coordination of protection.
  4. During commissioning, verify start-up of the whole assembly, the voltage at the load and behaviour after a power failure. Mains wiring and interventions are carried out by a qualified person according to the documentation, de-energised and after securing the workplace.

FAQ

Can I connect two outputs and get double the current?

Only with parallel operation permitted by the manufacturer and meeting its conditions. Redundancy also requires capacity for the fault state and suitable separation of branches; the difference is described in PULS: parallel operation and redundancy. Two power supplies loaded together to the maximum do not provide backup if one fails.

Will a more powerful power supply solve every PLC restart?

No. First separate insufficient power from voltage drop on the wiring, overload of one branch, interference or an intermittent contact. Record during which event the problem occurs; replacement without this distinction may leave the real cause untouched.

Pliki cookies na tej stronie

Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.