Power Supplies

Power supplies for automation, control cabinets and machines – 5, 12, 24 and 48 V DC switched-mode supplies for DIN rail and panel mounting from MEAN WELL, Siemens, Omron, Balluff, IDEC and others. Choose by output voltage and current with reserve, supply network, dimensions and operating temperature.

Podkategorie

Filtry
Znaleziono 330 produktów

6EP3436-7SC00-3AX0, Siemens SITOP PSU6200 – regulated power supply 24 V DC / 20 A, Ex

Nr kat.: 6EP3436-7SC00-3AX0

6EP3436-7SC00-3AX0 Siemens SITOP PSU6200 is a regulated power supply with an output of 24 V DC / 20 A and a version for three-phase AC input. Designed for automation control cabinets, PLCs…

Na zapytanie
329,46 €
bez VAT · 398,65 € z VAT

6EP1334-7CA10, Siemens SITOP PSU100P – regulated power supply 24 V DC / 8 A, IP67

Nr kat.: 6EP1334-7CA10

6EP1334-7CA10 Siemens SITOP PSU100P is a regulated power supply with an output of 24 V DC / 8 A and a version for single-phase AC input. Designed for installations directly at the machine outside a…

Na zapytanie
329,46 €
bez VAT · 398,64 € z VAT

S8VK-X12024A-EIP OMRON – power supply S8VK-X, 120 W, 24 V DC / 5 A

Nr kat.: S8VK-X12024A-EIP

S8VK-X12024A-EIP OMRON is an industrial power supply of the S8VK-X. series with a power of 120 W, an output of 24 V DC and a rated current of 5 A. Version: Smart / network power supply. Supply /…

Na zapytanie
335,25 €
bez VAT · 405,66 € z VAT

S8VK-G48024 OMRON – power supply S8VK-G, 480 W, 24 V DC / 20 A

Nr kat.: S8VK-G48024

S8VK-G48024 OMRON is an industrial power supply of the S8VK-G. series with a power of 480 W, an output of 24 V DC and a rated current of 20 A. Version: Pro, DIN rail. Supply / phase: 1f. Connection…

Na zapytanie
335,54 €
bez VAT · 406,00 € z VAT

6EP3437-8UB00-0AY0, Siemens SITOP PSU3800 – charging power supply 24 V DC / 30–40 A

Nr kat.: 6EP3437-8UB00-0AY0

6EP3437-8UB00-0AY0 Siemens SITOP PSU3800 is a charging power supply with an output of 24 V DC / 30–40 A and a version for three-phase AC input. Designed for industrial DC systems with a battery where…

Na zapytanie
336,86 €
bez VAT · 407,60 € z VAT

S8VK-G48048 OMRON – power supply S8VK-G, 480 W, 48 V DC / 10 A

Nr kat.: S8VK-G48048

S8VK-G48048 OMRON is an industrial power supply of the S8VK-G. series with a power of 480 W, an output of 48 V DC and a rated current of 10 A. Version: Pro, DIN rail. Supply / phase: 1f. Connection…

Na zapytanie
338,82 €
bez VAT · 409,98 € z VAT

SDR-960-48, Mean Well, switched-mode DIN-rail power supply, 48VDC/20A, 960W

Nr kat.: SDR-960-48

SDR-960-48 Mean Well – switched-mode power supply of the SDR-960 series for DIN rail, 960W, 48VDC/20A, input 180–264VAC. Suitable for industrial control cabinets, PLCs, HMIs, sensors, relays and…

Na zapytanie
342,71 €
bez VAT · 414,68 € z VAT

6EP3336-7SC00-3AX0, Siemens SITOP PSU6200 – regulated power supply 24 V DC / 20 A, Ex

Nr kat.: 6EP3336-7SC00-3AX0

6EP3336-7SC00-3AX0 Siemens SITOP PSU6200 is a regulated power supply with an output of 24 V DC / 20 A and a version for single-phase AC input. Designed for automation control cabinets, PLCs…

Na zapytanie
344,84 €
bez VAT · 417,25 € z VAT

6EP3337-8SB00-0AY0, Siemens SITOP PSU8200 – regulated power supply 24 V DC / 40 A

Nr kat.: 6EP3337-8SB00-0AY0

6EP3337-8SB00-0AY0 Siemens SITOP PSU8200 is a regulated power supply with an output of 24 V DC / 40 A and a version for single-phase AC input. Designed for PLCs, HMIs, sensors, actuators and other…

Na zapytanie
363,20 €
bez VAT · 439,48 € z VAT

S8VK-T48024 OMRON – power supply S8VK-T, 480 W, 24 V DC / 20 A

Nr kat.: S8VK-T48024

S8VK-T48024 OMRON is an industrial power supply of the S8VK-T. series with a power of 480 W, an output of 24 V DC and a rated current of 20 A. Version: Three-phase DIN power supply. Supply / phase…

Na zapytanie
368,52 €
bez VAT · 445,91 € z VAT

S8VK-WB24024 OMRON – power supply S8VK-WB, 240 W, 24 V DC / 10 A

Nr kat.: S8VK-WB24024

S8VK-WB24024 OMRON is an industrial power supply of the S8VK-WB. series with a power of 240 W, an output of 24 V DC and a rated current of 10 A. Version: Three-phase DIN power supply. Supply / phase…

Na zapytanie
369,55 €
bez VAT · 447,16 € z VAT

S8VK-WB24048 OMRON – power supply S8VK-WB, 240 W, 48 V DC / 5 A

Nr kat.: S8VK-WB24048

S8VK-WB24048 OMRON is an industrial power supply of the S8VK-WB. series with a power of 240 W, an output of 48 V DC and a rated current of 5 A. Version: Three-phase DIN power supply. Supply / phase…

Na zapytanie
369,55 €
bez VAT · 447,16 € z VAT

6EP3437-8SB00-4AY0, Siemens SITOP PSU8400 – regulated power supply 24 V DC / 40 A, IO-Link

Nr kat.: 6EP3437-8SB00-4AY0

6EP3437-8SB00-4AY0 Siemens SITOP PSU8400 is a regulated power supply with an output of 24 V DC / 40 A and a version for three-phase AC input. Designed for production lines, control cabinets and…

Na zapytanie
369,74 €
bez VAT · 447,39 € z VAT

S8VK-S48024 OMRON – power supply S8VK-S, 480 W, 24 V DC / 20 A

Nr kat.: S8VK-S48024

S8VK-S48024 OMRON is an industrial power supply of the S8VK-S. series with a power of 480 W, an output of 24 V DC and a rated current of 20 A. Version: DIN, coated. Supply / phase: 1f. Connection…

Na zapytanie
372,90 €
bez VAT · 451,20 € z VAT

S8VK-X24024-EIP OMRON – power supply S8VK-X, 240 W, 24 V DC / 10 A

Nr kat.: S8VK-X24024-EIP

S8VK-X24024-EIP OMRON is an industrial power supply of the S8VK-X. series with a power of 240 W, an output of 24 V DC and a rated current of 10 A. Version: Smart / network power supply. Supply /…

Na zapytanie
377,39 €
bez VAT · 456,64 € z VAT

6EP3436-8SB00-2AY0, Siemens SITOP PSU8600 – regulated power supply 24 V DC / 20 A, PROFINET

Nr kat.: 6EP3436-8SB00-2AY0

6EP3436-8SB00-2AY0 Siemens SITOP PSU8600 is a regulated power supply with an output of 24 V DC / 20 A and a version for three-phase AC input. Designed for machines with higher requirements for…

Na zapytanie
384,38 €
bez VAT · 465,10 € z VAT

6EP3447-8SB00-0AY0, Siemens SITOP PSU8200 – regulated power supply 48 V DC / 20 A

Nr kat.: 6EP3447-8SB00-0AY0

6EP3447-8SB00-0AY0 Siemens SITOP PSU8200 is a regulated power supply with an output of 48 V DC / 20 A and a version for three-phase AC input. Designed for PLCs, HMIs, sensors, actuators and other…

Na zapytanie
387,36 €
bez VAT · 468,71 € z VAT

S8VS-06024A OMRON – power supply S8VS-A/B, 60 W, 24 V DC / 2.5 A

Nr kat.: S8VS-06024A

S8VS-06024A OMRON is an industrial power supply of the S8VS-A/B. series with a power of 60 W, an output of 24 V DC and a rated current of 2.5 A. Version: DIN power supply. Supply / phase: 1f…

Na zapytanie
409,77 €
bez VAT · 495,82 € z VAT

S8VK-T48024-400 OMRON – power supply S8VK-T, 480 W, 24 V DC / 20 A

Nr kat.: S8VK-T48024-400

S8VK-T48024-400 OMRON is an industrial power supply of the S8VK-T. series with a power of 480 W, an output of 24 V DC and a rated current of 20 A. Version: Three-phase DIN power supply. Supply /…

Na zapytanie
424,72 €
bez VAT · 513,91 € z VAT

6EP3437-7SC00-3AX0, Siemens SITOP PSU6200 – regulated power supply 24 V DC / 40 A, Ex

Nr kat.: 6EP3437-7SC00-3AX0

6EP3437-7SC00-3AX0 Siemens SITOP PSU6200 is a regulated power supply with an output of 24 V DC / 40 A and a version for three-phase AC input. Designed for automation control cabinets, PLCs…

Na zapytanie
440,00 €
bez VAT · 532,40 € z VAT

6ES7148-4PC00-0HA0, Siemens SIMATIC ET 200pro PS – regulated power supply 24 V DC / 8 A, IP67

Nr kat.: 6ES7148-4PC00-0HA0

6ES7148-4PC00-0HA0 Siemens SIMATIC ET 200pro PS is a regulated power supply with an output of 24 V DC / 8 A and a version for three-phase AC input. Designed for decentralised automation and…

Na zapytanie
450,30 €
bez VAT · 544,86 € z VAT

S8AS2-24024-06S OMRON – power supply S8AS2, 240 W, 24 V DC / 10 A

Nr kat.: S8AS2-24024-06S

S8AS2-24024-06S OMRON is an industrial power supply of the S8AS2. series with a power of 240 W, an output of 24 V DC and a rated current of 10 A. Version: Power supply + electronic circuit breaker…

Na zapytanie
460,19 €
bez VAT · 556,83 € z VAT

S8AS2-24024-06SN OMRON – power supply S8AS2, 240 W, 24 V DC / 10 A

Nr kat.: S8AS2-24024-06SN

S8AS2-24024-06SN OMRON is an industrial power supply of the S8AS2. series with a power of 240 W, an output of 24 V DC and a rated current of 10 A. Version: Power supply + electronic circuit breaker…

Na zapytanie
460,19 €
bez VAT · 556,83 € z VAT

6EP3337-8SC00-0AY0, Siemens SITOP PSU8200 – regulated power supply 24 V DC / 40 A, Ex

Nr kat.: 6EP3337-8SC00-0AY0

6EP3337-8SC00-0AY0 Siemens SITOP PSU8200 is a regulated power supply with an output of 24 V DC / 40 A and a version for single-phase AC input. Designed for PLCs, HMIs, sensors, actuators and other…

Na zapytanie
481,06 €
bez VAT · 582,08 € z VAT

S8VK-X24024A-EIP OMRON – power supply S8VK-X, 240 W, 24 V DC / 10 A

Nr kat.: S8VK-X24024A-EIP

S8VK-X24024A-EIP OMRON is an industrial power supply of the S8VK-X. series with a power of 240 W, an output of 24 V DC and a rated current of 10 A. Version: Smart / network power supply. Supply /…

Na zapytanie
482,28 €
bez VAT · 583,56 € z VAT

Ceny zawierają opłatę recyklingową.

Power supplies

Choose a power supply as part of the entire supply circuit: from the mains feed through the control cabinet to the terminals of the most distant load. The correct output voltage is the first condition, not full confirmation of compatibility. The current during normal operation and start-up, the temperature inside the enclosure, protection, mounting method and the requirements of the connected equipment for protective separation are also decisive.

What this branch includes

The catalogue divides the range into the categories Allen-Bradley power supplies, IDEC 5/12/24V DC power supplies, CHINFA 12/24V DC power supplies, PULS 24V DC power supplies, Rievtech power supplies and Siemens power supplies. Catalogue items include, for example, CHINFA DRS1-24A and DRS5-24A, PULS PIC120.241C, Rievtech RPS-60-24 and several Siemens order codes. The parameters of these products are not common parameters of the whole category. The existence of the branch also does not confirm the availability of a specific type.

How a switched-mode regulated power supply works

A switched-mode power supply converts input energy using a rapidly switched power circuit; feedback adjusts the operation so that the output holds the required voltage within the permitted limits. Output filtering limits ripple but does not eliminate all transients. The basic difference from a linear power supply is described in the IDEC technical FAQ. For sensitive analogue measurement, therefore check not only the rated voltage but also the ripple, permissible interference and the routing of common return conductors.

Continuous load, simultaneity and peaks

List all loads by voltage branch. For each, record the highest operating current, short-term consumption, its duration and when it occurs. Do not calculate the coil current from the current capacity of its contacts; the figure on a relay output is not the relay's consumption. For equipment with externally powered outputs, check whether the documented consumption also includes the connected loads. Do not count the same current twice.

The required continuous current is determined by the worst permissible simultaneous operation, not by the average over a shift. Compare the peak with the overload characteristic of the selected power supply, including its duration and repetition. The boost designation alone is not enough. Design the reserve according to expansion and actual operating uncertainties; a universal percentage does not replace assessment of the start-up.

Model example of a current balance

Consider a hypothetical 24 V branch: the controller draws 0.45 A, the panel 0.35 A, eight sensors 0.03 A each and four simultaneously energised coils 0.12 A each. The sum is 1.52 A, i.e. 36.48 W. If the panel needs 1.10 A instead of 0.35 A at switch-on for 80 ms, the simultaneous consumption rises to 2.27 A. These are chosen inputs for the example, not data of the devices offered.

A power supply with a rated current of 2 A cannot be approved from the first sum alone, nor automatically rejected from the second: the permissible time characteristic and the voltage drop will decide. If we do not know it, we do not assume a short-term reserve. Delaying some loads can only help if their sequence is also ensured after the power supply is restored.

Derating, losses and space in the control cabinet

Derating means reducing the permissible load under specified conditions. It may relate to ambient temperature, altitude or a different mounting position; the curve of the specific type is decisive, as explained in the PULS guide to derating. The upper operating temperature is not automatically the temperature for full power. Assess the air at the power supply, not just the room temperature.

Your own design check should include the width on the rail, the depth including terminals, conductor bending and the prescribed ventilation clearances. Losses also belong in the heat balance. As a model, with an output of 100 W and an assumed efficiency of 90 %, approximately 11.1 W of heat is generated: 100 / 0.90 − 100. However, determine the efficiency of the chosen product for the actual load. Free space above the device does not replace verification of airflow in the enclosure.

Input inrush current and protection

AC inrush is a short input current when charging capacitors after connection to the mains. It is not the same as the starting current of a load on the DC output. The cause and methods of limiting it are described in the PULS documentation on inrush current. When several power supplies are switched on together, check the entire feed, the switching element and the manufacturer's recommendations. The ratio of output watts to mains voltage alone is not enough to choose a circuit breaker.

On the output, coordinate the protection of the individual branches with the current limiting of the power supply and the resistance of the wiring. The power supply may limit the current before an ordinary circuit breaker trips quickly; this relationship is discussed in PULS: protection of DC circuits. The specific solution must suit the cabling, load and required selectivity. The internal protection of the power supply does not automatically replace the protection of every branch.

SELV and PELV are not designations of 24 V

Both extra-low-voltage protective systems require appropriate protective separation from higher-voltage circuits. SELV maintains separation from earth; PELV allows earthing according to the protection design. The difference is explained in Schneider Electric documentation on SELV and the relationship between SELV and PELV. Connecting the protective conductor to the chassis of the power supply is not the same as connecting the negative output to earth.

Assess suitability for the whole circuit, including connections to other devices. 24 V alone, a plastic housing or the general brand of the manufacturer do not prove SELV or PELV. The equipment requirements, specific documents and earthing method must match.

Voltage at the load and verification procedure

Also check the voltage at the load at maximum consumption. As a model, a total loop resistance of 0.4 Ω at 1.5 A creates a drop of 0.6 V. By increasing the supply voltage you may overload nearby devices; first assess the conductors, length and distribution of branches.

  1. Verify the input network, number of phases, output voltage and polarity.
  2. Compare the current balance with the permissible load after derating and with the start-up.
  3. Check the mounting, terminals, protective connection and coordination of protection.
  4. During commissioning, verify start-up of the whole assembly, the voltage at the load and behaviour after a power failure. Mains wiring and interventions are carried out by a qualified person according to the documentation, de-energised and after securing the workplace.

FAQ

Can I connect two outputs and get double the current?

Only with parallel operation permitted by the manufacturer and meeting its conditions. Redundancy also requires capacity for the fault state and suitable separation of branches; the difference is described in PULS: parallel operation and redundancy. Two power supplies loaded together to the maximum do not provide backup if one fails.

Will a more powerful power supply solve every PLC restart?

No. First separate insufficient power from voltage drop on the wiring, overload of one branch, interference or an intermittent contact. Record during which event the problem occurs; replacement without this distinction may leave the real cause untouched.

Pliki cookies na tej stronie

Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.