Circuit Breakers and Residual Current Devices

Miniature circuit breakers and residual current devices for protecting electrical circuits and people. The range includes MCBs with B, C and D characteristics, DC circuit breakers, RCDs and combined RCBOs. Choose by rated current, number of poles, characteristic and breaking capacity.

Podkategorie

Filtry
Znaleziono 108 produktów
NASZA PORADA DOSTĘPNY

6SM325B, Sigma Elektrik, circuit breaker 3-phase, 25A, characteristic B, 6kA, (25A/B/3f), 25 A, 6 kA

Nr kat.: 6SM325B

6SM325B Sigma Elektrik – circuit breaker 3-phase, 25A, characteristic B, 6kA, (25A/B/3f), 25 A, 6 kA. Key data: 6SM. Exact technical data for selecting the miniature circuit breaker type.

Dostępny 5 i więcej szt.
4,48 €
bez VAT · 5,42 € z VAT
NASZA PORADA DOSTĘPNY

8CB30610D, Gregoo, miniature circuit breaker 3P, 6A, characteristic D, 10kA

Nr kat.: 8CB30610D

8CB30610D, Gregoo, miniature circuit breaker 3P, 6A, characteristic D, 10kA. The three-pole miniature circuit breaker GREGOO 8CB30610D with rated current 6A and characteristic D is designed to…

Dostępny 5 i więcej szt.
4,61 €
bez VAT · 5,57 € z VAT
NASZA PORADA DOSTĘPNY

8CB31610D, Gregoo, miniature circuit breaker, 3P, 16A, characteristic D, 10kA

Nr kat.: 8CB31610D

8CB31610D, Gregoo: miniature circuit breaker 3P/16A with tripping characteristic D and declared breaking capacity 10kA.

Dostępny 5 i więcej szt.
4,61 €
bez VAT · 5,57 € z VAT
NASZA PORADA DOSTĘPNY

8CB32010D, Gregoo, miniature circuit breaker, 3P, 20A, characteristic D, 10kA

Nr kat.: 8CB32010D

8CB32010D, Gregoo: miniature circuit breaker 3P/20A with tripping characteristic D and declared breaking capacity 10kA.

Dostępny 5 i więcej szt.
4,61 €
bez VAT · 5,57 € z VAT
NASZA PORADA DOSTĘPNY

AX3111, Sigma Elektrik, NOARK, auxiliary changeover contact for circuit breakers type Ex9BN, 100540

Nr kat.: AX3111

AX3111 Sigma Elektrik – NOARK, auxiliary changeover contact for circuit breakers type Ex9BN, 100540. Exact technical data for selecting the miniature circuit breaker type.

Dostępny 5 i więcej szt.
8,70 €
bez VAT · 10,52 € z VAT
DOSTĘPNY

EKL1-63-1P+N-16A/AC, CHANGAN, residual current device 1P+N, 16A, 30mA, type AC, 10kA

Nr kat.: EKL1-63-1P+N-16A/AC

EKL1-63-1P+N-16A/AC, CHANGAN, two-pole residual current device 1P+N for network 230VAC, rated current 16A, sensitivity 30mA, type AC and conditional short-circuit current 10kA. DIN rail mounting…

Dostępny 5 i więcej szt.
8,74 €
bez VAT · 10,58 € z VAT
NASZA PORADA DOSTĘPNY

Ex9L-N 2P 16A 30mA, NOARK, residual current device, 16 A

Nr kat.: Ex9L-N 2P 16A 30mA

Ex9L-N 2P 16A 30mA NOARK – residual current device, 16 A. Key data: 30 mA. Exact technical data for selecting the residual current device / RCBO type.

Dostępny 5 i więcej szt.
22,32 €
bez VAT · 27,01 € z VAT
DOSTĘPNY

Ex9L-N 4P 40A 100mA, NOARK, residual current device, 4P, 40A, 100mA, type A

Nr kat.: Ex9L-N 4P 40A 100mA

Ex9L-N 4P 40A 100mA, NOARK: four-pole type A residual current device, 40A, residual sensitivity 100mA, without overcurrent protection.

Dostępny 1 ks
36,47 €
bez VAT · 44,13 € z VAT
DOSTĘPNY

Ex9L-N 2P 40A 30mA, NOARK, residual current device 2P, 40A, 30mA, type A

Nr kat.: Ex9L-N 2P 40A 30mA

Ex9L-N 2P 40A 30mA, NOARK, residual current device 2P, 40A, 30mA, type A. The two-pole residual current device of the Ex9L-N series is designed to monitor residual current in a single-phase…

Dostępny 1 ks
45,86 €
bez VAT · 55,49 € z VAT
NASZA PORADA

6SM106B, Sigma Elektrik, miniature circuit breaker 1P, 6A, characteristic B, 6kA

Nr kat.: 6SM106B

6SM106B, Sigma Elektrik, miniature circuit breaker 1P, 6A, characteristic B, 6kA. The single-pole Sigma Electric SND series circuit breaker 6000 for a current of 6A with characteristic B protects the…

Na zapytanie
0,82 €
bez VAT · 1,00 € z VAT
NASZA PORADA

6SM106C, Sigma Elektrik, circuit breaker 1-phase, 6A, characteristic C, 6kA, (6A/C/1f), 6 A, 6 kA

Nr kat.: 6SM106C

6SM106C Sigma Elektrik – circuit breaker 1-phase, 6A, characteristic C, 6kA, (6A/C/1f), 6 A, 6 kA. Key data: 6SM. Exact technical data for selecting the miniature circuit breaker type.

Na zapytanie
0,82 €
bez VAT · 1,00 € z VAT
NASZA PORADA

1SM106C, Sigma Elektrik, circuit breaker 1-phase, 6A, characteristic C, breaking capacity 10kA, (6A/C/1f), elektronik

Nr kat.: 1SM106C

1SM106C Sigma Elektrik – circuit breaker 1-phase, 6A, characteristic C, breaking capacity 10kA, (6A/C/1f), elektronik. Key data: 10 kA, 6 A. Exact technical data for selecting the miniature circuit…

Na zapytanie
1,85 €
bez VAT · 2,24 € z VAT
NASZA PORADA

EKM1-63-1P-4A/B, CHANGAN, circuit breaker 1-pole, 4A, characteristic B, 6 kA, 4 A, 6kA

Nr kat.: EKM1-63-1P-4A/B

EKM1-63-1P-4A/B CHANGAN – circuit breaker 1-pole, 4A, characteristic B, 6 kA, 4 A, 6kA. Key data: EKM1-OF. Exact technical data for selecting the miniature circuit breaker type.

Na zapytanie
2,01 €
bez VAT · 2,44 € z VAT
NASZA PORADA

EKM1-63H-1P-04A/B, CHANGAN, circuit breaker 1-pole, 4A, characteristic B, 10kA, 04 A

Nr kat.: EKM1-63H-1P-04A/B

EKM1-63H-1P-04A/B CHANGAN – circuit breaker 1-pole, 4A, characteristic B, 10kA, 04 A. Key data: EKM1-OF. Exact technical data for selecting the miniature circuit breaker type.

Na zapytanie
2,34 €
bez VAT · 2,83 € z VAT
NASZA PORADA

EKM1-63H-1P-10A/B, CHANGAN, circuit breaker 1-pole, 10A, characteristic B, 10kA, 10 A

Nr kat.: EKM1-63H-1P-10A/B

EKM1-63H-1P-10A/B CHANGAN – circuit breaker 1-pole, 10A, characteristic B, 10kA, 10 A. Key data: Value. Exact technical data for selecting the miniature circuit breaker type.

Na zapytanie
2,34 €
bez VAT · 2,83 € z VAT
NASZA PORADA

EKM1-63-1P-02A/C, CHANGAN, circuit breaker 1-pole, 2A, characteristic C, 6 kA, 2 A, 6kA

Nr kat.: EKM1-63-1P-02A/C

EKM1-63-1P-02A/C CHANGAN – circuit breaker 1-pole, 2A, characteristic C, 6 kA, 2 A, 6kA. Key data: Value. Exact technical data for selecting the miniature circuit breaker type.

Na zapytanie
2,46 €
bez VAT · 2,98 € z VAT
NASZA PORADA

EKM1-63DC-1P-01A/C, CHANGAN, circuit breaker for DC circuits 1P, 1A, characteristic C, 250VDC, 6kA

Nr kat.: EKM1-63DC-1P-01A/C

EKM1-63DC-1P-01A/C, CHANGAN, circuit breaker for DC circuits 1P, 1A, characteristic C, 250VDC, 6kA. DC circuit breaker EKM1-63DC for protecting DC distribution systems; 250VDC applies to the…

Na zapytanie
2,46 €
bez VAT · 2,98 € z VAT
NASZA PORADA

Ex9BN 1P B6, NOARK, miniature circuit breaker 1P, 6A, characteristic B, 6kA

Nr kat.: Ex9BN 1P B6

Ex9BN 1P B6, NOARK, miniature circuit breaker 1P, 6A, characteristic B, 6kA. Miniature circuit breaker Ex9BN protects single-phase or three-phase branches according to the number of poles 1P.

Na zapytanie
2,87 €
bez VAT · 3,48 € z VAT
NASZA PORADA

Ex9BN 1P B16, NOARK, miniature circuit breaker 1P, 16A, characteristic B, Icn 6kA

Nr kat.: Ex9BN 1P B16

Ex9BN 1P B16, NOARK, miniature circuit breaker 1P, 16A, characteristic B, Icn 6kA. Single-pole circuit breaker Ex9BN with characteristic B and current 16A for protecting AC circuits against overload…

Na zapytanie
2,87 €
bez VAT · 3,48 € z VAT
NASZA PORADA

1SM206C, Sigma Elektrik, two-pole circuit breaker, 6A, tripping characteristic C, 10kA, (6A/C/2f), 6 A, 10 kA

Nr kat.: 1SM206C

1SM206C Sigma Elektrik – two-pole circuit breaker, 6A, tripping characteristic C, 10kA, (6A/C/2f), 6 A, 10 kA. Key data: 1SM. Exact technical data for selecting the miniature circuit breaker type.

Na zapytanie
3,29 €
bez VAT · 3,98 € z VAT

Ceny zawierają opłatę recyklingową.

Circuit breakers and RCDs

Choose circuit breakers and residual current devices according to the faults that the specific circuit must handle safely. The figure in amps, the number of modules or the appearance of the toggle are not a complete brief. The design links the power source, wiring, loads and fault conditions. This category helps distinguish protective functions and prepare data for professional selection; it does not replace the design or verification of the installation.

Circuit breaker, RCD and RCBO

An MCB circuit breaker responds to overcurrent. A residual current device RCCB on its own monitors residual current and has no overcurrent protection of its own. A combined RCBO joins both functions. The distinction is also confirmed by the Schneider Electric technical explanation. The designation “RCD” is therefore not enough: for the specific device, verify whether it is an RCCB or RCBO and how the downstream protection is arranged.

For each offer, read the data sheet for the exact order code. Data taken from another size or a related series may look credible but may not apply to the product being assessed. Unclear data must be resolved before the device is included in the project, not only during its installation.

Orientation in the range

Four values that must not be confused

The rated current In describes the current size of the device. The tripping characteristic of a circuit breaker expresses its response to overcurrent as a function of time. Breaking capacity refers to interrupting the short-circuit current under specified conditions. For an RCD, the rated residual operating current IΔn is also important. Each value answers a different question; a higher number by itself does not mean more suitable protection.

Add the voltage, AC or DC use, number and function of poles, type of residual sensitivity and environmental conditions to the comparison. Separately check coordination with the upstream protection. Selectivity cannot be confirmed by simply comparing two rated currents; request documentation for the specific combination.

Author's example: why the 16 A designation is not enough

The model list contains three devices marked 16 A: a circuit breaker, an RCD alone and a combined RCBO. The match of this number does not make them replacements. The purchase table must have separate columns “protective function”, “voltage”, “poles”, “characteristic” and “residual sensitivity”. An empty mandatory cell means missing documentation, not assumed conformity.

Mounting and diagnostics in context

Before ordering, check the module space, connection terminals, compatibility of the busbar and any auxiliary contact. Entrust mounting, measurement and commissioning to a qualified person. After the protection trips, record the circumstances: the load being switched on, the operating time and other loads started at the same time. Repeated switching on without finding the cause or arbitrarily increasing the current value is not a solution to the fault.

FAQ

Is an RCD a replacement for a circuit breaker?

An RCCB on its own is not. The required protective functions must be provided by a correctly designed assembly or a corresponding combined device.

What should be supplied with a replacement request?

A photo of the whole rating plate, the full code, the circuit diagram and data on the supply and load. Also attach the requirements for coordination of protection and the reason for replacement. The same width is not enough to confirm interchangeability.

Pliki cookies na tej stronie

Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.