6075489, SICK, ultrasonic label sensor UFS3-37P115, fork 2.6mm, PNP, IO-Link, 10–30VDC, Cable 2m
UFS3-37P115 (6075489), SICK – ultrasonic label sensor, fork 2.6mm, PNP, IO-Link, 10–30VDC, Cable 2m. Parameters, wiring and manufacturer documentation.
Kurs 24,39 Kč za 1 EUR. Ceny są orientacyjne, rozliczenie następuje w koronach czeskich.
Special ultrasonic sensors for double sheet, label and splice detection, through-beam detection and hydraulic cylinder position measurement. Choose the version according to the task, mounting and operating environment.
UFS3-37P115 (6075489), SICK – ultrasonic label sensor, fork 2.6mm, PNP, IO-Link, 10–30VDC, Cable 2m. Parameters, wiring and manufacturer documentation.
UFS3-37P117 (6075480), SICK – ultrasonic label sensor, fork 2.6mm, PNP, IO-Link, 10–30VDC, Cable 2m. Parameters, wiring and manufacturer documentation.
UFS3-37P415 (6075483), SICK – ultrasonic label sensor, fork 2.6mm, PNP, IO-Link, 10–30VDC, Connector M8/4. Parameters, wiring and manufacturer documentation.
UFS3-37P417 (6075474), SICK – ultrasonic label sensor, fork 2.6mm, PNP, IO-Link, 10–30VDC, Connector M8/4. Parameters, wiring and manufacturer documentation.
UFS3-37P515 (6075486), SICK – ultrasonic label sensor, fork 2.6mm, PNP, IO-Link, 10–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
UFS3-37P517 (6075477), SICK – ultrasonic label sensor, fork 2.6mm, PNP, IO-Link, 10–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
UFW3-43B717IZZ (6086478), SICK – ultrasonic web edge sensor, fork 30mm, PNP/NPN, 4–20mA/0–10V, IO-Link. Parameters, wiring and manufacturer documentation.
UFW3-43B717ZZZ (6086479), SICK – ultrasonic web edge sensor, fork 30mm, PNP/NPN, 4–20mA/0–10V, IO-Link. Parameters, wiring and manufacturer documentation.
UFW6-73B717IZZ (6086480), SICK – ultrasonic web edge sensor, fork 60mm, PNP/NPN, 4–20mA/0–10V, IO-Link. Parameters, wiring and manufacturer documentation.
UFW6-73B717ZZZ (6086481), SICK – ultrasonic web edge sensor, fork 60mm, PNP/NPN, 4–20mA/0–10V, IO-Link. Parameters, wiring and manufacturer documentation.
UR18.TB0.2-ZZZZ.9SF – ultrasonic through-beam emitter BAUMER. Range 0–2000mm. Connector M12, 5 pins. IP69.
UR12.EA0-GP2C.7BCU – ultrasonic through-beam receiver BAUMER. Range 0–1000mm. Output push-pull. Cable 2m, 5 wires. IP67.
UR12.EA0-GP2C.7BF – ultrasonic through-beam receiver BAUMER. Range 0–1000mm. Output push-pull. Connector M12, 5 pins. IP67.
UR12.TA0-ZZZX.7BCU – ultrasonic through-beam emitter BAUMER. Range 0–1000mm. Cable 2m, 5 wires. IP67.
UR12.TA0-ZZZX.7BF – ultrasonic through-beam emitter BAUMER. Range 0–1000mm. Connector M12, 5 pins. IP67.
U300.EA0-GP2J.72CU – ultrasonic through-beam receiver BAUMER. Range 0–1000mm. Output push-pull. Cable 2m, 4 wires. IP67.
U300.EA0-GP2J.72N – ultrasonic through-beam receiver BAUMER. Range 0–1000mm. Output push-pull. Connector M8, 4 pins. IP67.
U300.TA0-ZZZX.72CU – ultrasonic through-beam emitter BAUMER. Range 0–1000mm. Cable 2m, 4 wires. IP67.
U300.TA0-ZZZX.72N – ultrasonic through-beam emitter BAUMER. Range 0–1000mm. Connector M8, 4 pins. IP67.
UF200.EA0-GP2J.72CV – ultrasonic through-beam receiver BAUMER. Range 0–1000mm. Output push-pull. Cable 2m, 4 wires. IP67.
UF200.EA0-GP2J.72N – ultrasonic through-beam receiver BAUMER. Range 0–1000mm. Output push-pull. Connector M8, 4 pins. IP67.
UF200.EB0-GP2J.72CV – ultrasonic through-beam receiver BAUMER. Range 0–2000mm. Output push-pull. Cable 2m, 4 wires. IP67.
UF200.EB0-GP2J.72N – ultrasonic through-beam receiver BAUMER. Range 0–2000mm. Output push-pull. Connector M8, 4 pins. IP67.
UF200.TA0-ZZZX.72CV – ultrasonic through-beam emitter BAUMER. Range 0–1000mm. Cable 2m, 4 wires. IP67.
UF200.TA0-ZZZX.72N – ultrasonic through-beam emitter BAUMER. Range 0–1000mm. Connector M8, 4 pins. IP67.
Ceny zawierają opłatę recyklingową.
Special ultrasonic sensors differ in measuring principle, design and the environment for which they are intended. First determine whether you need to detect an object, check material layers or measure position. Choose the group according to this task and only then compare the range, outputs and mounting.
| Sensor group | Typical task |
|---|---|
| Ultrasonic double material detection | Sheet feeding, detection of missing and multiple material |
| Ultrasonic label and splice sensors | Label detection and detection of splices in material webs |
| Ultrasonic through-beam barriers | Detection of objects between a separate emitter and receiver |
| Fork ultrasonic sensors | Detection in the fixed gap of a fork housing |
| Ultrasonic position sensors for hydraulic cylinders | Position monitoring in short-stroke hydraulic cylinders |
| Hygienic ultrasonic sensors | Diffuse sensing and through-beam barriers in hygienic stainless steel design |
| Amplifiers and evaluation units | Signal evaluation for a compatible ultrasonic head |
The Pepperl+Fuchs UDC series are used to monitor single and multiple feeding. For labelling and winding machines, compare ULB sensors for labels and UGB sensors for splices. For assessment, prepare an actual sample of the material, its thickness or grammage and speed of movement.
A split ultrasonic through-beam barrier uses a separate emitter and receiver. A fork housing holds both parts at a fixed distance. For cleaned environments, the range includes UMC stainless steel sensors and UME through-beam barriers; here also compare materials, mounting accessories and cleaning conditions.
For short-stroke hydraulic cylinders, choose specialised BALLUFF BFD sensors. The variants offered monitor position in the range 0–80 mm. Amplifiers, for example IPF UV540000,, are a different type of solution: they evaluate the signal of a compatible sensing head and are selected as part of the corresponding assembly.
Help with choosing a specific model is provided by TECHNOLINE technical support. For other versions, continue to the complete ultrasonic sensor catalogue or vyberte sensor cables and connectors.
Start with the required result: distinguishing sheet layers, labels or splices, interruption of a through-beam barrier, cylinder position or sensing in a cleaned environment. Then compare the design, speed and output of the specific series.
These devices evaluate a different task. Double material detection distinguishes the states of sound passing through layers, while a diffuse distance sensor evaluates the echo from the target. Assess the replacement according to the function of the entire assembly.
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.