6058960, SICK, ultrasonic label sensor UFN3-70B113, fork 3mm, PNP/NPN, 10–30VDC
UFN3-70B113 (6058960), SICK – ultrasonic label sensor, fork 3mm, PNP/NPN, 10–30VDC. Parameters, wiring and manufacturer documentation.
Kurs 24,39 Kč za 1 EUR. Ceny są orientacyjne, rozliczenie następuje w koronach czeskich.
Pepperl+Fuchs ULB ultrasonic sensors for labels and UGB for web splices. Choose according to the sensed layer, carrier material, passage speed and PLC connection.
UFN3-70B113 (6058960), SICK – ultrasonic label sensor, fork 3mm, PNP/NPN, 10–30VDC. Parameters, wiring and manufacturer documentation.
UFN3-70B413 (6049678), SICK – ultrasonic label sensor, fork 3mm, PNP/NPN, 10–30VDC. Parameters, wiring and manufacturer documentation.
UFN3-70B417 (6058742), SICK – ultrasonic label sensor, fork 3mm, PNP/NPN, 10–30VDC. Parameters, wiring and manufacturer documentation.
UFN3-70N415 (6049680), SICK – ultrasonic label sensor, fork 3mm, NPN, 10–30VDC. Parameters, wiring and manufacturer documentation.
UFN3-70N417 (6058744), SICK – ultrasonic label sensor, fork 3mm, NPN, 10–30VDC. Parameters, wiring and manufacturer documentation.
UFN3-70P415 (6049679), SICK – ultrasonic label sensor, fork 3mm, PNP, 10–30VDC. Parameters, wiring and manufacturer documentation.
UFN3-70P417 (6058743), SICK – ultrasonic label sensor, fork 3mm, PNP, 10–30VDC. Parameters, wiring and manufacturer documentation.
UFS3-37B115 (6075488), SICK – ultrasonic label sensor, fork 2.6mm, PNP/NPN, IO-Link, 10–30VDC, Cable 2m. Parameters, wiring and manufacturer documentation.
UFS3-37B117 (6075479), SICK – ultrasonic label sensor, fork 2.6mm, PNP/NPN, IO-Link, 10–30VDC, Cable 2m. Parameters, wiring and manufacturer documentation.
UFS3-37B415 (6075482), SICK – ultrasonic label sensor, fork 2.6mm, PNP/NPN, IO-Link, 10–30VDC, Connector M8/4. Parameters, wiring and manufacturer documentation.
UFS3-37B417 (6075473), SICK – ultrasonic label sensor, fork 2.6mm, PNP/NPN, IO-Link, 10–30VDC, Connector M8/4. Parameters, wiring and manufacturer documentation.
UFS3-37B515 (6075485), SICK – ultrasonic label sensor, fork 2.6mm, PNP/NPN, IO-Link, 10–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
UFS3-37B517 (6075476), SICK – ultrasonic label sensor, fork 2.6mm, PNP/NPN, IO-Link, 10–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
UFS3-37N115 (6075490), SICK – ultrasonic label sensor, fork 2.6mm, NPN, IO-Link, 10–30VDC, Cable 2m. Parameters, wiring and manufacturer documentation.
UFS3-37N117 (6075481), SICK – ultrasonic label sensor, fork 2.6mm, NPN, IO-Link, 10–30VDC, Cable 2m. Parameters, wiring and manufacturer documentation.
UFS3-37N415 (6075484), SICK – ultrasonic label sensor, fork 2.6mm, NPN, IO-Link, 10–30VDC, Connector M8/4. Parameters, wiring and manufacturer documentation.
UFS3-37N417 (6075475), SICK – ultrasonic label sensor, fork 2.6mm, NPN, IO-Link, 10–30VDC, Connector M8/4. Parameters, wiring and manufacturer documentation.
UFS3-37N515 (6075487), SICK – ultrasonic label sensor, fork 2.6mm, NPN, IO-Link, 10–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
UFS3-37N517 (6075478), SICK – ultrasonic label sensor, fork 2.6mm, NPN, IO-Link, 10–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
UFS3-37P115 (6075489), SICK – ultrasonic label sensor, fork 2.6mm, PNP, IO-Link, 10–30VDC, Cable 2m. Parameters, wiring and manufacturer documentation.
UFS3-37P117 (6075480), SICK – ultrasonic label sensor, fork 2.6mm, PNP, IO-Link, 10–30VDC, Cable 2m. Parameters, wiring and manufacturer documentation.
UFS3-37P415 (6075483), SICK – ultrasonic label sensor, fork 2.6mm, PNP, IO-Link, 10–30VDC, Connector M8/4. Parameters, wiring and manufacturer documentation.
UFS3-37P417 (6075474), SICK – ultrasonic label sensor, fork 2.6mm, PNP, IO-Link, 10–30VDC, Connector M8/4. Parameters, wiring and manufacturer documentation.
UFS3-37P515 (6075486), SICK – ultrasonic label sensor, fork 2.6mm, PNP, IO-Link, 10–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
UFS3-37P517 (6075477), SICK – ultrasonic label sensor, fork 2.6mm, PNP, IO-Link, 10–30VDC, Connector M12/4. Parameters, wiring and manufacturer documentation.
Ceny zawierają opłatę recyklingową.
Ultrasonic sensing evaluates the passage of sound through the material between the emitter and receiver. On labelling equipment, it helps distinguish the label area on the carrier web; when processing rolls, a suitable version can detect splices and glued sections. Selection starts with what change the sensor is to report.
Prepare a sample of the label, carrier or splice and data on the highest web speed. Compare the smallest gap, the position of the web in the measuring space and the sensor response time. Printing and colour are not the same limitation for ultrasonic evaluation as for the optical principle; verify the usability of the specific combination of layers on a sample.
When wiring, verify the PNP or NPN output, contact logic, pulse length and Teach-in procedure. With a split assembly, maintain the relative position of the heads and the compatibility of its parts.
There are separate ULB and UGB series in the range for the two tasks. When changing the application, compare the evaluated states and the relevant manual.
Manufacturer's documentation: ULB – etikety and UGB – web splices.
A label sample together with the carrier web, the smallest gap between labels and the highest line speed. The whole combination of layers, the web guidance and the required output to the control system are important.
Choose ULB for detecting labels on a carrier, UGB for detecting splices in a material web. For both series, verify the specific material, response and electrical design according to the complete order code.
For selection or replacement, send the complete order code and a description of the application. TECHNOLINE technical support will help compare the required version.
Related: Double sheet detection · Fork sensors · All special ultrasonic sensors · Sensor Cables and Connectors.
Techniczne pliki cookies są potrzebne do działania koszyka i zamówienia — są używane zawsze. Analityczne pliki cookies pokazują nam, których stron ludzie szukają i gdzie się gubią, i pomagają nam ulepszać sklep. Użyjemy ich tylko wtedy, gdy na to pozwolisz. Więcej w zasadach przetwarzania danych.
Wybierz, których plików cookies możemy używać. Wybór możesz w każdej chwili zmienić.
Przechowują zawartość koszyka, logowanie i wybrany język oraz chronią formularze przed nadużyciem. Bez nich nie można złożyć zamówienia, dlatego są używane także bez zgody.
Usługa Google Analytics pokazuje nam ruch i zachowanie na stronie w formie zbiorczej. Dzięki temu wiemy, które strony nie działają dla ludzi. Na podstawie tych danych nikogo nie identyfikujemy.