Pneumatic valves

SMC, Festo and TECHNOLINE pneumatic valves for controlling actuators – 3/2, 5/2 and 5/3 directional valves, base plates for valve terminals and accessories. Choose by function, port, actuation and coil voltage.

Sottocategorie

Filtri
Trovati 196 prodotti

SY7120-5YO-C10F-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SY7120-5YO-C10F-Q

SY7120-5YO-C10F-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
70,03 €
IVA esclusa · 84,74 € IVA inclusa

SYJ5140-5MOZ-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SYJ5140-5MOZ-Q

SYJ5140-5MOZ-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
70,44 €
IVA esclusa · 85,24 € IVA inclusa

SY5120-5LOU-C4F-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SY5120-5LOU-C4F-Q

SY5120-5LOU-C4F-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
70,44 €
IVA esclusa · 85,24 € IVA inclusa

AD402-N02C-6Z-A, SMC, condensate drain valve

Cod. cat.: AD402-N02C-6Z-A

AD402-N02C-6Z-A, SMC, condensate drain valve. The air preparation element filters, regulates or otherwise prepares the compressed air for the pneumatic system.

Su richiesta
71,26 €
IVA esclusa · 86,23 € IVA inclusa

SY5120-5LOU-C6F-Q, solenoid valve, SMC

Cod. cat.: SY5120-5LOU-C6F-Q

solenoid 5/2 valve; monostable; voltage: 24V DC; SMC

Su richiesta
71,67 €
IVA esclusa · 86,72 € IVA inclusa

SY9120-5YO-03F-Q, SMC, solenoid valve

Cod. cat.: SY9120-5YO-03F-Q

SY9120-5YO-03F-Q, SMC, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
71,67 €
IVA esclusa · 86,72 € IVA inclusa

SY7120-5LOU-C8F-Q, SMC, solenoid 5/2 valve, monostable, 24 V DC, tube Ø 8 mm

Cod. cat.: SY7120-5LOU-C8F-Q

SY7120-5LOU-C8F-Q, SMC, solenoid 5/2 valve, monostable, 24 V DC, tube Ø 8 mm. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
72,66 €
IVA esclusa · 87,91 € IVA inclusa

SY7120-5YO-C8F-Q, solenoid pilot-operated valve, SMC

Cod. cat.: SY7120-5YO-C8F-Q

SY7120-5YO-C8F-Q, solenoid pilot-operated valve, SMC

Su richiesta
72,90 €
IVA esclusa · 88,21 € IVA inclusa

VQZ215K-5YB1-Q, solenoid pilot-operated valve, SMC

Cod. cat.: VQZ215K-5YB1-Q

VQZ215K-5YB1-Q, solenoid pilot-operated valve, SMC

Su richiesta
72,90 €
IVA esclusa · 88,21 € IVA inclusa

SY7120-5YOD-02F-Q, solenoid valve, SMC

Cod. cat.: SY7120-5YOD-02F-Q

solenoid valve; voltage: 24VDC; SMC

Su richiesta
72,90 €
IVA esclusa · 88,21 € IVA inclusa

SY513-4YO-C6F-Q, SMC, solenoid pilot-operated valve with threads in body

Cod. cat.: SY513-4YO-C6F-Q

SY513-4YO-C6F-Q, SMC, solenoid pilot-operated valve with threads in body. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
72,90 €
IVA esclusa · 88,21 € IVA inclusa

VQC2101NR-51, solenoid pilot-operated valve, SMC

Cod. cat.: VQC2101NR-51

VQC2101NR-51, solenoid pilot-operated valve, SMC

Su richiesta
73,23 €
IVA esclusa · 88,61 € IVA inclusa

SY513-5YO-C8F-Q, SMC, solenoid valve

Cod. cat.: SY513-5YO-C8F-Q

SY513-5YO-C8F-Q SMC – solenoid valve. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
73,31 €
IVA esclusa · 88,71 € IVA inclusa

SY5160-5LOU-C6-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SY5160-5LOU-C6-Q

SY5160-5LOU-C6-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
73,51 €
IVA esclusa · 88,95 € IVA inclusa

SY7120-4YO-02F-X10-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SY7120-4YO-02F-X10-Q

SY7120-4YO-02F-X10-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
73,72 €
IVA esclusa · 89,20 € IVA inclusa

SY5220-5DO-01F-Q, solenoid valve, SMC

Cod. cat.: SY5220-5DO-01F-Q

SY5220-5DO-01F-Q, solenoid pilot-operated valve, SMC

Su richiesta
74,13 €
IVA esclusa · 89,70 € IVA inclusa

SS5Y5-60-09U-10-Q, SMC, sub-plate

Cod. cat.: SS5Y5-60-09U-10-Q

SS5Y5-60-09U-10-Q SMC – sub-plate. The exact variant is determined by the manufacturer's order code.

Su richiesta
74,10 €
IVA esclusa · 89,67 € IVA inclusa

SS5Y5-42-02-C6F-Q, sub-plate, SMC

Cod. cat.: SS5Y5-42-02-C6F-Q

SS5Y5-42-02-C6F-Q, multiple sub-plate - aluminium, individual electrical connection, SMC

Su richiesta
74,92 €
IVA esclusa · 90,66 € IVA inclusa

SY5240-5LZ-Q, solenoid pilot-operated valve , SMC

Cod. cat.: SY5240-5LZ-Q

SY5240-5LZ-Q, solenoid pilot-operated valve , SMC

Su richiesta
75,77 €
IVA esclusa · 91,68 € IVA inclusa

VUVG-LK10-T32C-AT-M5-1R8L-S, solenoid valve, 8042542, Festo

Cod. cat.: VUVG-LK10-T32C-AT-M5-1R8L-S

solenoid valve; voltage: 24VDC; frequency: 2 Hz; 8042542; Festo

Su richiesta
76,79 €
IVA esclusa · 92,92 € IVA inclusa

VMPA1-M1H-M-PI, Festo, solenoid valve, 533342

Cod. cat.: VMPA1-M1H-M-PI

VMPA1-M1H-M-PI Festo – solenoid valve, 533342. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
76,99 €
IVA esclusa · 93,16 € IVA inclusa

SYJ712-5DZ-01F-F-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SYJ712-5DZ-01F-F-Q

SYJ712-5DZ-01F-F-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
79,04 €
IVA esclusa · 95,64 € IVA inclusa

SY3120-5WAOU-M5-Q, solenoid pilot-operated valve, SMC

Cod. cat.: SY3120-5WAOU-M5-Q

SY3120-5WAOU-M5-Q, solenoid pilot-operated valve, SMC

Su richiesta
79,45 €
IVA esclusa · 96,14 € IVA inclusa

SY3240-5MOZ-Q, SMC, solenoid pilot-operated valve

Cod. cat.: SY3240-5MOZ-Q

SY3240-5MOZ-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
79,94 €
IVA esclusa · 96,73 € IVA inclusa

I prezzi includono il contributo di riciclaggio.

Pneumatic valves

The range includes SMC, Festo and TECHNOLINE pneumatic valves, including the TE3V/TE4V, SY, VQ, VX and VDW series. For selection, it is useful to separate the valve itself, its connection base and electrical accessories.

What the valve actually switches

The designation 5/2 expresses five main ports and two positions; 5/3 adds a third position with a defined connection of channels. The specific Festo VUVG-LK10-M52-AT-M5-1R8L-S is a monostable 5/2 with internal pilot supply. In contrast, VUVS-L25-P53E-MD-G14-F8-1C1 has the 5/3 function with an exhaust centre position. The number of coils alone does not replace reading the pneumatic symbol.

Closing a single flow path is a different requirement. Separate SMC VDW documentation describes direct-operated 2-way valves and distinguishes variants by medium. Documentation VX21/22/23 similarly distinguishes versions for water, air and other media. Inclusion in the pneumatic category therefore does not by itself confirm the suitability of each item for any liquid.

Selection starts with a description of the working sequence

For your own design, write down which branches should be pressurised and which exhausted for each command. In addition to the working cycle, describe a power failure, loss of air supply and restart. These are three separate situations; assess them according to the diagram of the specific valve and the whole machine.

Then compare the full order code, medium, required flow rate, working pressures and electrical connection. In the category Valves choose the functional version; Plates for terminals addresses the common arrangement of the assembly. For the decision, prepare a sketch of the actual line lengths, service clearances and consumer positions. Also record the measuring points for the acceptance test in the sketch.

Model calculation: volume of connecting hoses

Let us consider only a model assembly of eight hoses, each with an inner diameter of 6 mm and a length of 3 m. The geometric volume of one hose is V = π × d² × L / 4 = π × 0.006² × 3 / 4 = 0.0000848 m³, approximately 0.0848 litres. Eight hoses contain approximately 0.679 litres of internal space.

If each route is shortened to 1.5 m, the total drops to approximately 0.339 litres. The calculation compares only the geometry of two designs. It is not the free air consumption, switching time or parameters of the hoses or valves sold. For a time calculation, it would be necessary to add pressure conditions, the flow characteristic and the volume of the connected equipment.

Mounting and troubleshooting

Instructions SMC for VDW mounting require clean piping and prevention of sealing material entering the valve. When dismantling, it is necessary to disconnect the medium, release the pressure and switch off the power supply. A functional check follows assembly. Always take the specific mounting position and tightening from the documentation of the ordered version.

For the diagnostic record, compare the command, the voltage at the connected coil and the pressures upstream and downstream of the valve at the same moment. Record whether the fault occurs at the first switching, after warming up or during simultaneous operation of other branches. Such a distinction will help decide which part of the circuit to investigate further.

FAQ

Is an identical thread enough for replacement?

No. Compare the function, rest state, pilot version, medium and electrical equipment. The thread describes only one interface; also prepare the original diagram and the full order code.

Does an illuminated connector prove that the valve has switched?

Do not use the indicator light alone as acceptance proof of pneumatic function. Verify the actual response of the circuit. Select electrical parts in the category Accessories according to the exact version of the coil and connector.

Cookie su questo sito

I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.