Valves

3/2, 5/2 and 5/3 pneumatic directional valves with electrical, pneumatic or manual actuation. Choose by function, rest position, port and coil voltage.

Filtri
Trovati 174 prodotti
IL NOSTRO CONSIGLIO DISPONIBILE

TE4V310-10-NC-DC24V-LD, valve, TECHNOLINE

Cod. cat.: TE4V310-10-NC-DC24V-LD

TE4V310-10-NC-DC24V-LD, valve 5/2 NC with spring and one coil power supply 24VDC, connection 3/8" with illuminated connector, TECHNOLINE

Disponibile 5 pz e oltre
19,35 €
IVA esclusa · 23,41 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

TE3V310-10-NC-DC24V-LD, valve, TECHNOLINE

Cod. cat.: TE3V310-10-NC-DC24V-LD

TE3V310-10-NC-DC24V-LD, valve 3/2 NC with spring and one coil, power supply 24VDC, connection 3/8 with illuminated connector, TECHNOLINE

Disponibile 5 pz e oltre
19,35 €
IVA esclusa · 23,41 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

TE4V310-10-NO-DC24V-LD, valve, TECHNOLINE

Cod. cat.: TE4V310-10-NO-DC24V-LD

TE4V310-10-NO-DC24V-LD, valve 5/2 NO with spring and one coil, power supply 24VDC, connection 3/8 with illuminated connector, TECHNOLINE

Disponibile 5 pz e oltre
19,59 €
IVA esclusa · 23,71 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

TE3V310-10-NO-DC24V-LD, valve, TECHNOLINE

Cod. cat.: TE3V310-10-NO-DC24V-LD

TE3V310-10-NO-DC24V-LD, valve 3/2 NO with spring and one coil, power supply 24VDC, connection 3/8 with illuminated connector, TECHNOLINE

Disponibile 5 pz e oltre
21,52 €
IVA esclusa · 26,04 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

TE4V320-10-NC-DC24V-LD, valve, TECHNOLINE

Cod. cat.: TE4V320-10-NC-DC24V-LD

TE4V320-10-NC-DC24V-LD, valve 5/2 NC with spring and two coils power supply 24VDC, connection 3/8 with illuminated connector, TECHNOLINE

Disponibile 5 pz e oltre
25,82 €
IVA esclusa · 31,24 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

TE3V320-10-NC-DC24V-LD, valve, TECHNOLINE

Cod. cat.: TE3V320-10-NC-DC24V-LD

TE3V320-10-NC-DC24V-LD, valve 3/2 NC with two coils, power supply 24VDC, connection 3/8 with illuminated connector, TECHNOLINE

Disponibile 5 pz e oltre
25,82 €
IVA esclusa · 31,24 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

TE4V320-10-NO-DC24V-LD, valve, TECHNOLINE

Cod. cat.: TE4V320-10-NO-DC24V-LD

TE4V320-10-NO-DC24V-LD, valve 5/2 NO with spring and two coils, power supply 24VDC, connection 3/8 with illuminated connector, TECHNOLINE

Disponibile 5 pz e oltre
27,95 €
IVA esclusa · 33,82 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

TE3V320-10-NO-DC24V-LD, valve, TECHNOLINE

Cod. cat.: TE3V320-10-NO-DC24V-LD

TE3V320-10-NO-DC24V-LD, valve 3/2 NO with two coils, power supply 24VDC, connection 3/8 with illuminated connector, TECHNOLINE

Disponibile 5 pz e oltre
27,95 €
IVA esclusa · 33,82 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

TE4V330C-10-NC-DC24V-LD, valve, TECHNOLINE

Cod. cat.: TE4V330C-10-NC-DC24V-LD

TE4V330C-10-NC-DC24V-LD, valve 5/3 NC with spring and two coils, closed centre position, power supply 24VDC, connection 3/8 with illuminated connector, TECHNOLINE

Disponibile 5 pz e oltre
32,29 €
IVA esclusa · 39,07 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

TE4V330E-10-NC-DC24V-LD, valve, TECHNOLINE

Cod. cat.: TE4V330E-10-NC-DC24V-LD

TE4V330E-10-NC-DC24V-LD, valve 5/3 NC with spring and two coils, open centre position, power supply 24VDC, connection 3/8 with illuminated connector, TECHNOLINE

Disponibile 5 pz e oltre
32,29 €
IVA esclusa · 39,07 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

TE4V330C-10-NO-DC24V-LD, valve, TECHNOLINE

Cod. cat.: TE4V330C-10-NO-DC24V-LD

TE4V330C-10-NO-DC24V-LD, valve 5/3 NO with spring and two coils, closed centre position, power supply 24VDC, connection 3/8 with illuminated connector, TECHNOLINE

Disponibile 5 pz e oltre
34,42 €
IVA esclusa · 41,64 € IVA inclusa
IL NOSTRO CONSIGLIO DISPONIBILE

TE4V330E-10-NO-DC24V-LD, valve, TECHNOLINE

Cod. cat.: TE4V330E-10-NO-DC24V-LD

TE4V330E-10-NO-DC24V-LD, valve 5/3 NO with spring and two coils, open centre position, power supply 24VDC, connection 3/8 with illuminated connector, TECHNOLINE

Disponibile 5 pz e oltre
34,42 €
IVA esclusa · 41,64 € IVA inclusa
DISPONIBILE

VZOA-3-1/4 3464, SMC, Time-delay solenoid valve, Festo

Cod. cat.: VZOA-3-1/4 3464

VZOA-3-1/4 3464 SMC – Time-delay solenoid valve, Festo. When selecting, verify the connection, size and other parameters of the specific variant.

Disponibile 1 ks
640,56 €
IVA esclusa · 775,07 € IVA inclusa

VDW22QAA, SMC, solenoid 2/2 valve, 24 V DC

Cod. cat.: VDW22QAA

VDW22QAA, SMC, solenoid 2/2 valve, 24 V DC. A pneumatic valve controls the direction, pressure or flow of the medium in a pneumatic circuit.

Su richiesta
21,07 €
IVA esclusa · 25,49 € IVA inclusa

V111-5LOU, SMC, direct-operated solenoid 3/2 valve, standard version

Cod. cat.: V111-5LOU

V111-5LOU, SMC, direct-operated solenoid 3/2 valve, standard version. A pneumatic valve controls the direction, pressure or flow of the medium in a pneumatic circuit.

Su richiesta
26,64 €
IVA esclusa · 32,23 € IVA inclusa

VHS20-F01-D, single-stage valve, SMC

Cod. cat.: VHS20-F01-D

VHS20-F01-D, single-stage valve, SMC

Su richiesta
28,27 €
IVA esclusa · 34,21 € IVA inclusa

AQ3000-03, SMC, quick exhaust valve

Cod. cat.: AQ3000-03

AQ3000-03 SMC – quick exhaust valve. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
33,39 €
IVA esclusa · 40,40 € IVA inclusa

VT307K-4D1-01F-Q, SMC, solenoid 3/2 valve

Cod. cat.: VT307K-4D1-01F-Q

VT307K-4D1-01F-Q, SMC, solenoid 3/2 valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
38,10 €
IVA esclusa · 46,10 € IVA inclusa

VX212EZ3AA, SMC, solenoid valve

Cod. cat.: VX212EZ3AA

VX212EZ3AA, SMC, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
38,92 €
IVA esclusa · 47,09 € IVA inclusa

VT307-5DO1-01F-Q, SMC, solenoid valve

Cod. cat.: VT307-5DO1-01F-Q

VT307-5DO1-01F-Q, SMC, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
40,35 €
IVA esclusa · 48,83 € IVA inclusa

VQ21A1-5YO-C6-F-Q, SMC, solenoid 2/2 valve of series VQ20, 24 V DC, port C6

Cod. cat.: VQ21A1-5YO-C6-F-Q

VQ21A1-5YO-C6-F-Q SMC – solenoid 2/2 valve of series VQ20, 24 V DC, port C6. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
40,80 €
IVA esclusa · 49,37 € IVA inclusa

VM132-M5-30BA, SMC, 3/2 valve

Cod. cat.: VM132-M5-30BA

VM132-M5-30BA, SMC, 3/2 valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
41,79 €
IVA esclusa · 50,56 € IVA inclusa

MS4-LR-1/4-D5-AS, pressure reducing valve, 529415, Festo

Cod. cat.: MS4-LR-1/4-D5-AS

MS4-LR-1/4-D5-AS, pressure reducing valve, 529415, Festo

Su richiesta
41,79 €
IVA esclusa · 50,56 € IVA inclusa

MS4-LR-1/4-D6-AS, pressure reducing valve, 529417, Festo

Cod. cat.: MS4-LR-1/4-D6-AS

MS4-LR-1/4-D6-AS, pressure reducing valve, 529417, Festo

Su richiesta
43,01 €
IVA esclusa · 52,05 € IVA inclusa

I prezzi includono il contributo di riciclaggio.

Pneumatic directional valves

A directional valve controls the connection of the supply, working paths and exhaust according to its functional symbol. For selection, you need the required state of the actuator and the behaviour when the command and energy change. The number of ways alone does not describe the rest or centre position.

Selection data Valves

Step What to document
Identification symbol, number of ways and positions
Operating requirements pilot pressure and electrical actuation
Acceptance circuit switching and exhaust

The range here includes TE3V/TE4V, SMC SY, VQ, VX and VDW series as well as Festo valves. For a service replacement, start with the function of the original circuit and the full part code. Similar-looking bodies may represent different circuits.

Number of positions and rest state

At TECHNOLINE, they represent TE3V310-10-NC-DC24V-LD a TE3V310-10-NO-DC24V-LD two rest variants 3/2. NC means the supply path to the working output is closed in the home state, NO means it is open. When selecting, therefore, draw the required media path with the electrical command disconnected.

TE4V310-10-NC-DC24V-LD is 5/2, while TE4V330C-10-NC-DC24V-LD is a 5/3 with a closed centre position. NC or NO alone is not a complete description of all channels of a 5-way valve. For example, Festo VUVS-L25-P53E-MD-G14-F8-1C1 uses an exhaust centre. Read the specific arrangement from the symbol; do not create a replacement simply by counting the coils.

Pilot pressure and medium are separate criteria

Festo datasheet 8042543 explicitly states pilot operation and internal pilot air supply. For your own selection sheet, therefore, record the pressure of the working branch and the requirements of the pilot stage separately. For an external pilot, verify its separate supply according to the diagram. Electrical voltage alone does not confirm that the pneumatic conditions for switching are met.

For 2-way valves, the medium and the pressure differential are further distinguished. SMC manual VQ20/30 requires a minimum differential of 0.01 MPa for opening. Catalogue VX21/22/23 separates the highest system pressure from the highest working pressure differential. Record both input values in the comparison; a high pressure upstream of the valve alone is not enough.

Model calculation: pressure upstream of the valve is insufficient

For our own example, let us assume pressures measured against the same reference: 0.43 MPa upstream of the valve and 0.425 MPa downstream. The difference is Δp = 0.43 − 0.425 = 0.005 MPa, i.e. 5 kPa. With our own design requirement of at least 20 kPa, this model situation does not comply, even though there is significant overpressure at the inlet.

If, in the second model situation, the outlet pressure drops to 0.40 MPa, the difference increases to 30 kPa. This only meets the considered pressure differential condition. The example does not determine the flow rate, opening time or suitability of a specific valve. The actual values must be determined during the working sequence, not taken from the compressor setting.

Mounting and targeted diagnostics

Before disconnecting, ensure a de-energised and depressurised state. The VQ20/30 manual requires a functional test and leak check after mounting. For this series, it also points out that a locked manual override can change the response to switching off the electrical command. Therefore, include the manual override position in the check before start-up.

As our own diagnostic procedure, record the command, voltage and pressure conditions at the same time. Compare a standalone cycle with simultaneous operation of other consumers. If the problem occurs only in the assembly, add to the check Plates for terminals and the connected line. Look up the electrical variant via Accessories, always according to the full code.

FAQ

Is the 5/2 valve a replacement for 5/3?

This cannot be assumed without changing the required function. Also include the behaviour of the third position in the comparison and verify whether the working sequence actually needs it.

Can the permitted medium be determined from the series designation?

Only in combination with the exact variant and its documentation. For orientation in the whole range, use Pneumatic valves; inclusion of a product alone does not confirm its suitability for water, oil or vacuum.

Cookie su questo sito

I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.