MHZL2-16D, SMC, 2 fingers, double-acting, Ø16mm, stroke 12mm
MHZL2-16D, SMC – pneumatic long-stroke parallel gripper; Number of fingers: 2; Piston diameter: 16mm; Opening/closing stroke: 12mm.
Cambio 24,43 Kč per 1 EUR. I prezzi sono indicativi, la fatturazione avviene in corone ceche.
SMC pneumatic grippers and gripper heads for handling parts in automation – parallel, angular and three-jaw. Choose by gripping force, jaw stroke, part weight and finger length.
MHZL2-16D, SMC – pneumatic long-stroke parallel gripper; Number of fingers: 2; Piston diameter: 16mm; Opening/closing stroke: 12mm.
MHS3-16D, SMC – pneumatic 3-finger gripper; Number of fingers: 3; Piston diameter: 16mm; Total opening/closing stroke: 4mm (measured across the diameter).
MHZL2-25D, SMC – pneumatic long-stroke parallel gripper; Number of fingers: 2; Piston diameter: 25mm; Opening/closing stroke: 22mm.
MHZ2-40C, SMC – pneumatic parallel gripper; Number of fingers: 2; Piston diameter: 40mm; Actuation: single-acting.
MHZ2-40D, SMC – pneumatic parallel gripper; Number of fingers: 2; Piston diameter: 40mm; Actuation: double-acting.
MHW2-40TFD, SMC – pneumatic angular gripper; Number of fingers: 2; Piston size: 40mm; Actuation: double-acting.
MHL2-40D, SMC – pneumatic parallel gripper; Piston diameter: 40mm; Number of fingers: 2; Total opening/closing stroke: 100mm.
MRHQ25D-180S-N, SMC – pneumatic rotary gripper; Number of fingers: 2 parallel; Piston diameter: 25mm; Gripping actuation: double-acting.
I prezzi includono il contributo di riciclaggio.
A pneumatic gripper ensures that a component is gripped in a handling or assembly device. When selecting, it is not enough to know the part weight and the finger spacing. The shape of the contact surfaces, the acceleration of the manipulator, the orientation of the part and the consequences of losing the grip are also important. This category includes SMC products of the MHZ, MHS, MHL, MHW and MRHQ series; do not transfer the parameters of one version to the others.
V SMC MHZ catalogue the effective gripping force in the relevant diagrams is expressed as the force of one finger in full contact with the part. It depends on the pressure and the distance of the gripping point. The diagram for external gripping must therefore not be used for internal gripping without distinction. The order designation MHZ2 distinguishes D for the double-acting version, S for the single-acting normally open version and C for the single-acting normally closed version.
For the design, first describe how the part is to be held: by friction between surfaces, by bearing against a shaped finger, or by a combination of both principles. The required force is not the same as the permitted load of a sensitive product. With thin-walled parts, a higher grip can cause deformation before slipping is reliably resolved.
Acceptance conditions should include the smallest and largest part, normal pressure fluctuations and the actual surface condition. A test with a single clean sample does not confirm the function with oil, burrs or dimensional deviation. Therefore, record the result together with the specific test conditions and machine settings.
Consider a purely model transverse force of 20 N acting at a distance of 30 mm from the selected support point. The moment is M = F·l = 20 × 0.03 = 0.60 N·m. By extending the distance to 60 mm with the same force, the moment increases to 1.20 N·m. The force has not changed, but the load on the arm bearing has doubled.
The calculation is not the permitted moment of any offered gripper. It serves to explain why your own extended fingers cannot be approved based on the size of the body alone. The actual design must compare all forces and moments with the limits of the specific product and take into account dynamic movement.
Before mounting, verify the alignment of the approach and that the fingers do not hit the fixture. Test repeatability with and without the product. If the problem occurs only during fast travel, record the acceleration and orientation, not just the set pressure. When replacing the fingers, repeat the acceptance test.
Supply the assembly with a suitable air preparation a pneumatic valve. For clamping a part in a fixed fixture, also compare pneumatic clamps; this is a different working task from transferring a gripped part.
A position signal alone does not confirm the required force or correct contact with the product. The required checks must correspond to the specific process and its risks.
Not reliably. First verify the contact geometry and the load on the product. The pressure can only be changed within the permitted range of all components and after a new test of the result.
I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.
Scegli quali cookie possiamo utilizzare. Puoi modificare la scelta in qualsiasi momento.
Conservano il contenuto del carrello, l'accesso e la lingua scelta e proteggono i moduli dagli abusi. Senza di essi non è possibile completare l'ordine, per questo sono utilizzati anche senza consenso.
Google Analytics ci mostra in forma aggregata il traffico e il comportamento sul sito. Così capiamo quali pagine non funzionano per gli utenti. In base a questi dati non identifichiamo nessuno.