Accessories

Accessories for pneumatic valves – coils, connectors and mounting parts. Choose by valve type and voltage.

Filtri
Trovati 14 prodotti
DISPONIBILE

TE4V Coil AC230V, TECHNOLINE, valve coil

Cod. cat.: TE4V Coil AC230V

TE4V Coil AC230V TECHNOLINE – valve coil. When selecting, verify the connection, size and other parameters of the specific variant.

Disponibile 5 pz e oltre
6,47 €
IVA esclusa · 7,83 € IVA inclusa

MSSD-EB, Festo, socket for solenoid valves, 151687

Cod. cat.: MSSD-EB

MSSD-EB, Festo, socket for solenoid valves, 151687. A pneumatic valve controls the direction, pressure or flow of the medium in a pneumatic circuit.

Su richiesta
2,66 €
IVA esclusa · 3,22 € IVA inclusa

DXT152-25-1A, SMC, mounting bracket for VT307

Cod. cat.: DXT152-25-1A

DXT152-25-1A SMC – mounting bracket for VT307. The exact variant is determined by the manufacturer's order code.

Su richiesta
3,07 €
IVA esclusa · 3,72 € IVA inclusa

SY7000-26-1A-Q, SMC, blanking plate for SY7000

Cod. cat.: SY7000-26-1A-Q

SY7000-26-1A-Q, SMC, blanking plate for SY7000. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
6,26 €
IVA esclusa · 7,58 € IVA inclusa

X32, TECHNOLINE, DIN connector with status indication and surge suppressor 24V DC, SMC

Cod. cat.: X32

X32 TECHNOLINE – DIN connector with status indication and surge suppressor 24V DC, SMC. The exact variant is determined by the manufacturer's order code.

Su richiesta
12,00 €
IVA esclusa · 14,52 € IVA inclusa

A6-24V-V-R, SMC, connector

Cod. cat.: A6-24V-V-R

A6-24V-V-R, SMC, connector. A cable or connector provides the electrical connection of specific elements of the equipment.

Su richiesta
14,94 €
IVA esclusa · 18,08 € IVA inclusa

MSFG-24/42-50/60-OD, Festo, solenoid coil, 34411

Cod. cat.: MSFG-24/42-50/60-OD

MSFG-24/42-50/60-OD Festo – solenoid coil, 34411. The exact variant is determined by the manufacturer's order code.

Su richiesta
16,79 €
IVA esclusa · 20,31 € IVA inclusa

SY30M-27-1-WO-01F, SMC, base plate for a single SY valve

Cod. cat.: SY30M-27-1-WO-01F

SY30M-27-1-WO-01F, SMC, base plate for a single SY valve. A solenoid valve electrically controls the direction of compressed air flow.

Su richiesta
52,41 €
IVA esclusa · 63,41 € IVA inclusa

VV3P3-41R-041-02F, SMC, multiple sub-plate for solenoid-operated valves

Cod. cat.: VV3P3-41R-041-02F

VV3P3-41R-041-02F SMC – multiple sub-plate for solenoid-operated valves. When selecting, verify the connection, size and other parameters of the specific variant.

Su richiesta
103,17 €
IVA esclusa · 124,84 € IVA inclusa

ZK2A10K5CLA-08, SMC, vacuum unit

Cod. cat.: ZK2A10K5CLA-08

ZK2A10K5CLA-08, SMC, vacuum unit. A vacuum unit or ejector generates vacuum for suction cups and vacuum handling.

Su richiesta
318,53 €
IVA esclusa · 385,43 € IVA inclusa

EX600-AXA, SMC, centralised serial wiring, analogue input unit

Cod. cat.: EX600-AXA

EX600-AXA SMC – centralised serial wiring, analogue input unit. The exact variant is determined by the manufacturer's order code.

Su richiesta
325,90 €
IVA esclusa · 394,33 € IVA inclusa

VBA11A-02, booster, SMC

Cod. cat.: VBA11A-02

VBA11A-02, booster, SMC

Su richiesta
362,78 €
IVA esclusa · 438,96 € IVA inclusa

VBA11A-02GN, SMC, booster

Cod. cat.: VBA11A-02GN

VBA11A-02GN, SMC, booster. The booster regulator increases the available compressed air pressure without a separate electrical drive.

Su richiesta
406,59 €
IVA esclusa · 491,97 € IVA inclusa

I prezzi includono il contributo di riciclaggio.

Accessories for pneumatic valves

Accessories for pneumatic valves can be seals, plugs, mounting or electrical parts. First determine their role in the drawing and the full type of the original assembly. Inclusion in accessories alone does not prove compatibility with every valve.

Selection data Accessories

Step What to document
Identification part identification and assembly series
Operating requirements scope of delivery and interface
Acceptance seating and function after replacement

The category combines coils, connectors, mounting parts and more complex units. The listing also includes EX600-AXA, ZK2A10K5CLA-08 and boosters VBA11A-02 and VBA11A-02GN. When selecting, therefore, start by determining the function of the part you are looking for.

The coil and the connector have their own specifications

TE4V Coil AC230V is specified in the TECHNOLINE documentation for 230 V AC power supply and series 300. For another offered coil Festo MSFG-24/42-50/60-OD, number 34411, the manufacturer states 24 V DC or 42 V AC at 50/60 Hz and the connection pattern for MSSD-F. These data belong to the given coil; do not transfer them to neighbouring items in the range.

For your own selection sheet, separate three checks: mechanical fixing of the coil on the valve, electrical power supply and the connector interface. Write down the full code of each part. For a variant with indication or a protective circuit, also request its diagram. The presence of a similarly shaped connector in the range does not by itself confirm a suitable combination.

Distinguishing electronic and vacuum units

SMC EX600-AXA is an analogue input unit with two channels. When adding it, verify the configuration of the whole system, the range of the connected signal and the data allocation in the controller. Do not use the input channel count as the number of outputs for controlling coils.

The offered ZK2A10K5CLA-08 belongs to vacuum units. Documentation of series ZK2 distinguishes various valve and sensor variants. For service, request documentation for the full code and generation. Membership of a series alone is not a basis for assigning communication equipment or the air-saving function.

Model calculation: load on the supply branch

Let us consider purely model DC coils, each with a power consumption of 2.4 W at a voltage of 24 V. For one coil, the current is I = P / U = 2.4 / 24 = 0.10 A. When six coils are switched on simultaneously, their steady-state total is 0.60 A and the power consumption 14.4 W.

If we add the assumed consumption of indication and other electronics of 0.15 A, the total is 0.75 A. With simultaneous operation of eight identical model coils, it is already 0.95 A. The result shows the effect of simultaneity, not a recommended size of power supply or fuse. It does not include pull-in currents, line losses or the permissible load of individual outputs. None of these values is a parameter of the offered accessories.

Preparing the mounting and verifying the repair

Before replacement, prepare the diagram, wire markings and a photo of the original wiring. Work in a secured de-energised state with the equipment depressurised. For the Festo 34411 coil, according to its datasheet the maximum tightening torque of the socket is 0.4 Nm; this value is not a universal torque for other connectors. Choose the mounting procedure together with the specific valve item.

As our own diagnostic sequence, first confirm the correct spare part code, then the wiring and finally the function in the working cycle. For a non-functioning branch, record the voltage under load and the valve response. For a fault after warming up, add the switching time and ambient conditions. Use the indicator light as auxiliary information, not as the only proof of a successful repair.

For mounting and sealing parts, also add the base type to the service record. Compare the offer with the category Plates for terminals; grouping several parts together is not a list of their permitted combinations.

FAQ

Can a coil be selected by voltage alone?

That is not enough. You also need the type of current, the mechanical design and confirmed use on the given valve. For the AC variant, check the prescribed frequency.

Must all accessories be electrical parts?

Not necessarily. Decide according to the function of the specific item and the requirements of the assembly. The wider context of the range is explained in the category Pneumatic valves.

Cookie su questo sito

I cookie tecnici servono per il funzionamento del carrello e dell'ordine — sono sempre utilizzati. I cookie analitici ci mostrano quali pagine le persone cercano e dove si perdono, e ci aiutano a migliorare il negozio. Li utilizziamo solo se ce lo consenti. Maggiori informazioni nella informativa sul trattamento dei dati.