Process Sensors

Process sensors measure pressure, temperature, flow and level in pipes and tanks. Here you will find pressure sensors in relative and absolute versions with G1/4 and G1/2, thread, Pt100 and Pt1000 temperature sensors including thermowells and compression fittings, flow meters for water, air and aggressive media, and float, capacitive and ultrasonic level sensors. Most models offer an analogue 4–20 mA or 0–10 V output for direct connection to a PLC; on switching versions the limit can be set on the device display. You can choose by measuring range, accuracy, material of the wetted parts, permissible media temperature and degree of protection up to IP69K. We supply sensors from TECHNOLINE, SICK, IFM and other brands. If needed, contact us and we will gladly help you choose the type for your application.

Subcategories

Filters
Found 168 products
OUR TIP

7MB2521-0CB00-1AA1, Siemens, CALOMAT 6 Siemens gas analyser for measuring Ar in O2

Cat. no.: 7MB2521-0CB00-1AA1

7MB2521-0CB00-1AA1 The Siemens CALOMAT 6 gas analyser uses the thermal conductivity measuring principle for accurate determination of argon concentration in oxygen. The 19″ rack unit with 6 mm pipes…

On request
5 550,47 €
excl. VAT · 6 716,07 € incl. VAT
OUR TIP

7MB2521-1AA00-1AA1, Siemens, CALOMAT 6 Siemens gas analyser for measuring H2 in N2

Cat. no.: 7MB2521-1AA00-1AA1

7MB2521-1AA00-1AA1 Siemens CALOMAT 6 is a reliable thermal conductivity analyser designed for measuring hydrogen concentration in nitrogen. Thanks to its wide measuring range (0–1 % to 0–100 %), it…

On request
5 550,47 €
excl. VAT · 6 716,07 € incl. VAT
OUR TIP

7MB2335-0AR06-3AA1, Siemens, ULTRAMAT 23 Siemens multi-component CO analyser with percentage range

Cat. no.: 7MB2335-0AR06-3AA1

7MB2335-0AR06-3AA1 The Siemens ULTRAMAT 23 multi-component analyser for measuring CO in the high percentage range (0–20 % to 0–100 %) is suitable for special process applications requiring detection…

On request
5 845,07 €
excl. VAT · 7 072,53 € incl. VAT
OUR TIP

7MB2335-0AH06-3AA1, Siemens, ULTRAMAT 23 Siemens multi-component CO analyser

Cat. no.: 7MB2335-0AH06-3AA1

7MB2335-0AH06-3AA1 The Siemens ULTRAMAT 23 multi-component gas analyser combines NDIR and UV technology for accurate CO measurement with the option of adding a O2. sensor. The 19″ plug-in unit is…

On request
6 019,65 €
excl. VAT · 7 283,77 € incl. VAT
OUR TIP

7MB2335-0AJ06-3AA1, Siemens, ULTRAMAT 23 Siemens multi-component CO analyser with extended range

Cat. no.: 7MB2335-0AJ06-3AA1

7MB2335-0AJ06-3AA1 Siemens ULTRAMAT 23 offers reliable CO measurement in an extended measuring range of 0–1000 to 0–5000 vpm. The multi-component design with the option of adding a O2 sensor is ideal…

On request
6 019,65 €
excl. VAT · 7 283,77 € incl. VAT
OUR TIP

7MB2335-0AK06-3AA1, Siemens, ULTRAMAT 23 Siemens multi-component CO analyser with high range

Cat. no.: 7MB2335-0AK06-3AA1

7MB2335-0AK06-3AA1 The Siemens ULTRAMAT 23 gas analyser with a high CO measuring range (0–2000 to 0–10 000 vpm) provides accurate data for processes with a higher concentration of carbon monoxide…

On request
6 019,65 €
excl. VAT · 7 283,77 € incl. VAT
OUR TIP

7MB2335-0NH06-3AA1, Siemens, ULTRAMAT 23 Siemens multi-component analyser SO2

Cat. no.: 7MB2335-0NH06-3AA1

7MB2335-0NH06-3AA1 Siemens ULTRAMAT 23 for measuring SO2 uses highly selective UV and NDIR technology and is a key instrument for emission monitoring of combustion and power plants in accordance with…

On request
6 706,71 €
excl. VAT · 8 115,12 € incl. VAT
OUR TIP

7MB2335-0PH06-3AA1, Siemens, ULTRAMAT 23 Siemens multi-component NO analyser

Cat. no.: 7MB2335-0PH06-3AA1

7MB2335-0PH06-3AA1 The Siemens ULTRAMAT 23 gas analyser for NO measurement provides accurate and stable data for emission control in combustion processes, power plants and other industrial…

On request
6 706,71 €
excl. VAT · 8 115,12 € incl. VAT
OUR TIP

7MB2041-0AA10-1AA1, Siemens, OXYMAT 64 Siemens trace oxygen analyser with ZrO2 sensor

Cat. no.: 7MB2041-0AA10-1AA1

7MB2041-0AA10-1AA1 Siemens OXYMAT 64 is a specialised trace oxygen analyser with a catalytically active ZrO2 sensor. It enables detection of O2 in the smallest traces and is equipped with internal…

On request
7 160,87 €
excl. VAT · 8 664,65 € incl. VAT
OUR TIP

7MB2021-1EA00-1AA1, Siemens, OXYMAT 6 Siemens oxygen analyser with non-flow compensation branch

Cat. no.: 7MB2021-1EA00-1AA1

7MB2021-1EA00-1AA1 The Siemens OXYMAT 6 oxygen analyser with a stainless steel non-flow compensation branch and FKM hose is designed for accurate measurement of O2 in corrosive and standard process…

On request
7 330,17 €
excl. VAT · 8 869,50 € incl. VAT
OUR TIP

7MB2335-0AM16-3AA1, Siemens, ULTRAMAT 23 Siemens multi-component CO analyser with O2 sensor

Cat. no.: 7MB2335-0AM16-3AA1

7MB2335-0AM16-3AA1 Siemens ULTRAMAT 23 with an integrated O2 sensor enables simultaneous measurement of CO in the percentage range (0–1 % to 0–5 %) and oxygen concentration, providing a comprehensive…

On request
7 607,65 €
excl. VAT · 9 205,26 € incl. VAT
OUR TIP

7MB2021-0CC00-1AA1, Siemens, OXYMAT 6 Siemens oxygen analyser with flow-through compensation branch

Cat. no.: 7MB2021-0CC00-1AA1

7MB2021-0CC00-1AA1 Siemens OXYMAT 6 is a paramagnetic oxygen analyser with high measurement accuracy and linearity, also suitable for corrosive gases. The version with a flow-through compensation…

On request
8 022,47 €
excl. VAT · 9 707,19 € incl. VAT
OUR TIP

7MB2337-0AL06-3PJ1, Siemens, ULTRAMAT 23 Siemens two-component CO/NO analyser with percentage CO range

Cat. no.: 7MB2337-0AL06-3PJ1

7MB2337-0AL06-3PJ1 Siemens ULTRAMAT 23 in a two-channel configuration measures CO in the percentage range together with NO, providing a complete overview of combustion quality and the emission…

On request
9 530,41 €
excl. VAT · 11 531,80 € incl. VAT
OUR TIP

7MB2337-0AH06-3PT1, Siemens, ULTRAMAT 23 Siemens two-component CO/NO analyser

Cat. no.: 7MB2337-0AH06-3PT1

7MB2337-0AH06-3PT1 The Siemens ULTRAMAT 23 two-component analyser measures CO and NO simultaneously in two independent channels, enabling comprehensive emission monitoring of combustion processes…

On request
9 822,55 €
excl. VAT · 11 885,29 € incl. VAT
OUR TIP

7MB2121-0CA00-1AA1, Siemens, ULTRAMAT 6E Siemens rack analyser CO2 with 6 mm pipes

Cat. no.: 7MB2121-0CA00-1AA1

7MB2121-0CA00-1AA1 The Siemens ULTRAMAT 6E rack gas analyser uses NDIR technology for continuous and highly selective measurement of CO2. The 19″ unit with 6 mm pipes is designed for installation in…

On request
11 342,94 €
excl. VAT · 13 724,96 € incl. VAT
OUR TIP

7MB2121-1CA00-1AA1, Siemens, ULTRAMAT 6E Siemens rack analyser CO2 with 1/4″ pipes

Cat. no.: 7MB2121-1CA00-1AA1

7MB2121-1CA00-1AA1 Siemens ULTRAMAT 6E is a single-channel NDIR analyser CO2 in a 19″ rack version with 1/4″ pipes. It offers accurate and stable measurement of infrared-active gases for process…

On request
11 342,94 €
excl. VAT · 13 724,96 € incl. VAT
OUR TIP

7MB2338-4AA06-3NH1, Siemens, ULTRAMAT 23 Siemens three-component analyser CO/NO/SO2 with two channels

Cat. no.: 7MB2338-4AA06-3NH1

7MB2338-4AA06-3NH1 The Siemens ULTRAMAT 23 three-component gas analyser with separate gas paths simultaneously measures CO, NO and SO2, making it a comprehensive solution for strict emission…

On request
12 296,40 €
excl. VAT · 14 878,64 € incl. VAT
OUR TIP

7MB2111-1AB00-1AA1, Siemens, ULTRAMAT 6 Siemens field CO analyser

Cat. no.: 7MB2111-1AB00-1AA1

7MB2111-1AB00-1AA1 The Siemens ULTRAMAT 6 field gas analyser uses NDIR (non-dispersive infrared) technology for accurate and continuous measurement of CO concentration directly in the field. The…

On request
12 343,63 €
excl. VAT · 14 935,80 € incl. VAT

Prices include the recycling fee.

Process Sensors

Process measurement should provide information on which a specific process can be controlled: topping up a tank, verifying cooling, regulating pressure or monitoring the composition of a medium. The first question is therefore not the sensor brand but the decision its signal is to support. To stop filling, detecting that a level has been reached may be enough; to record consumption, you need continuous measurement and correctly configured logging. Confusing these tasks leads to a device that responds but does not provide the data needed.

Which quantity do you need to measure?

Siemens gas analysers include the OXYMAT, ULTRAMAT and CALOMAT series. When choosing, ask not only about the monitored component but also about the rest of the gas mixture. The same oxygen content in different accompanying gases is not automatically the same measuring task.

Level sensors and probes include float switches, submersible pressure probes and radar devices. Decide whether you need a limit state, level height or volume. Height and volume are directly proportional only in a tank with a constant horizontal cross-section.

Category pH measurement contains the Orbipac CPF81D pH sensor and the Smartec CLD134. conductivity device. These are different quantities: the conductivity value alone does not determine the acidity or alkalinity of an unknown mixture.

Flow sensors offer IFM SI flow monitors, SM magnetic-inductive devices and the Prosonic Flow 91W. ultrasonic meter. To confirm flow and to totalise pumped litres, choose according to the different requirements for output and measuring function.

Temperature sensors include TECHNOLINE and ENDA Pt100 probes as well as a ring-lug thermocouple. The resistance input for Pt100 and the millivolt thermocouple input are not interchangeable. Besides the electronics, thermal contact with the measured point is decisive.

Pressure sensors include, for example, devices from IFM, SMC and Ema. Separate the pressure reference from the design of the measuring cell: absolute or relative pressure describes what the measurement is referenced to; ceramic or a metal diaphragm describes the sensor design.

Turbidity measurement are represented in the range by the Turbimax CUE21-A1S. Turbidity is an optical quantity; without a verified correlation for the specific suspension, it does not give the mass of suspended solids or direct proof of the health safety of water.

Choose range and principle together

Write down the normal minimum and maximum, start-up, shutdown and cleaning. The device must handle the actual operating state, but an unnecessarily wide range can reduce the usability of the measurement in the working area. For accuracy, distinguish between percent of measured value and percent of span. The number of decimal places on the display alone says nothing about the uncertainty of the result. Also include sensor location, drift, the transmitter and the control system input in the assessment.

The principle must match the medium. For example IFM datasheet SM6000 specifies a liquid conductivity of at least 20 µS/cm. This requirement belongs to this model, not automatically to all flow meters. When the liquid changes, keeping the same thread or the same current output is therefore not enough.

Process connection and electrical interface

For the material check, make a list of all wetted parts: diaphragm, electrodes, seals, flow chamber, cable sheath and adhesives if they come into contact with the medium. Assess concentration, temperature and exposure time, including cleaning agents. A resistant outer housing does not mean a resistant measuring path. A thread with the same designation does not yet confirm the correct sealing method. For pressure equipment, also check surges, vacuum and the combination of temperature and pressure.

Distinguish between the sensing element itself, the sensor with transmitter and the complete measuring system. Orbipac CPF81D according to the manufacturer uses Memosens; the digital connection of this sensor is not a synonym for an ordinary current loop. The input type, cable and any transmitter must form a compatible assembly.

For analogue transmission, check the supply, active or passive input, permissible load and diagnostic states. For a switching output, verify polarity, load capacity and hysteresis setting. If communication fails, the control program must distinguish an invalid value from a genuinely unchanging process. The last received number without a data-age flag can look plausible long after a measurement failure.

Plan acceptance of the assembly before ordering. Determine how you will verify several working points, the correctness of displayed units and the response to a fault. Also prepare a configuration record, sensor identification and space for service notes. This makes it possible to distinguish a real process change from a change of measurement settings during later replacement.

Model calculation: same milliamps, different reading

Consider only an illustrative linear transmitter with a range of 0–10 bar and a 4–20 mA output. For a current of 12 mA, p = (12 − 4) / (20 − 4) × 10 = 5 bar. If the control system input mistakenly used a range of 0–16 bar, it would display 8 bar. The difference of 3 bar arises from configuration, not from a sensor error. The example does not represent the parameters of any product offered.

Frequently asked questions before ordering

Is it enough to replace the device with another one with the same range?

No. Also compare the reference of the quantity, materials, dynamics, mounting position, supply and output. Replacement is complete only after verifying the entire measuring path, including correct units in the record and the meaning of alarms. Document the configuration of the original device first so that any change in the trend can be explained.

When should calibration and service be planned?

According to the criticality of the measurement, experience with drift and operating load, not by a single universal interval. Prepare access for checking, safe isolation from the process and records of interventions. Calibration compares the indication with a reference; adjusting the device is a separate step. Verifying one point does not prove the correctness of the whole range.

Does process measurement automatically mean a safety function?

No. An ordinary measuring signal alone does not establish suitability for personal protection or for use in explosive atmospheres. Such an application requires an appropriate design and documentation of the exact version of the entire assembly. The general series name or the range of communication functions does not replace this check.

Cookies on this website