Sensor Testers

Sensor testers for quickly checking inductive, capacitive and optical sensors off the machine. They show the PNP/NPN output type, NO/NC function and correct connection. They save time when troubleshooting and replacing sensors.

Filters
Found 2 products
OUR TIP IN STOCK

ST-800, SENSOR TESTER, sensor tester, PNP

Cat. no.: ST-800

ST-800 SENSOR TESTER – sensor tester, PNP, PNP and NPN. A tool for quick function checks of industrial sensors.

In stock 3 ks
36,43 €
excl. VAT · 44,09 € incl. VAT
OUR TIP

SENSOR TESTER, BOX-TYPE SENSOR TESTING DEVICE, PNP, NPN, NO and NC, Emas

Cat. no.: SENSOR TESTER

SENSOR TESTER BOX-TYPE SENSOR TESTING DEVICE – sensor tester, PNP, PNP and NPN. A tool for quick function checks of industrial sensors.

On request
27,15 €
excl. VAT · 32,85 € incl. VAT

Prices include the recycling fee.

Sensor Testers

A sensor tester is one of the tools for functional verification of a sensor during service. The category offers ST-800 sold under the Lanbao brand and the SENSOR TESTER product from EMAS. Before choosing, compare the supported sensor design with the instructions of the specific tester. The same designation or a similar housing is not proof of identical electrical wiring or the same permissible load.

Decision: first the output and supply method

Find out the number of wires, the supply requirements of the sensor and the type of output. PNP or NPN describes the electrical behaviour of the output, while NO or NC describes the switching function. Record these two pieces of information separately. For devices with analogue output, communication or unknown wiring, first request explicit confirmation of support; a simple switching indication may not match the purpose of the test.

As technical background for distinguishing outputs, you can use the explanation of three-wire sensors from Pepperl+Fuchs: with PNP the load is between the output and the negative supply potential, with NPN between the output and the positive potential. This principle helps to read the diagram, but does not give the permitted voltage or current of a specific tester.

Principle: monitor the response in both states

SUNS in the manual of its ST-800 describes a function test of three-wire DC sensors with optical and acoustic indication and explicitly excludes two-wire AC and DC sensors. With the NO function it evaluates switching when the target is present, with NC when the target is absent. This is SUNS product documentation; by itself it does not confirm identity with the Lanbao variant or the EMAS tester in this category.

A practical test record should contain the state without a target, the state with a target and repetition of the transition. A single lighting of the indicator says less than a repeatable transition between the two states. Also describe the target used and its position. If you change the material or distance of the target in the next test, the conditions are not directly comparable.

Mounting and connection: a separate assembly under test

Disconnect the sensor from the original circuit and wire it according to its diagram and the tester's instructions. Do not connect a powered PLC circuit in parallel with the tester unless the manufacturer explicitly allows such use. For a sensor with a connector, use a suitable connection cable and check which contacts its cores lead to. Do not consider the wire colour a substitute for checking the pinout.

Author's model example, not a product parameter

Consider a known inductive sensor with NO function and a metal target. During ten slow approaches the indication appears ten times and during ten withdrawals it disappears ten times. The result supports the conclusion that the output switches under these conditions. It does not confirm the rated range, maximum switching frequency, sealing or behaviour with the original PLC input. The numbers are an author's test scenario.

Diagnostics: a negative result is not an immediate verdict

If the sensor does not respond, check the compatibility of the tester, the wiring, the state of its supply and the suitability of the target. Only then evaluate the suspicion of a faulty sensor. Compare the test of the sensor alone with a test through the original cable. For branches routed through a passive distribution box also record the port number; without it the result is difficult to assign back to the installation.

After returning the sensor to the machine, check the expected input state and the control response. A bench test does not cover the mechanical alignment in operation or the entire line to the input module. Therefore close the record only with the result of verification in the original working arrangement.

FAQ

Is a sensor tester an inspection test instrument?

Do not consider a switching function test to be an inspection of the installation or a measurement of insulation resistance or electrical safety.

Can I automatically use the manual of another ST-800?

No. The match of manufacturer, variant and manual must be verified. A common model string alone is not enough.