Z70, EMAS, lift door contact, plug / fork
Z70 EMAS – lift door contact. Technical parameters, application and compatibility check.
Rate 24,43 CZK per 1 EUR. Prices are indicative, invoicing is in Czech crowns.
EMAS Z series lift door switches for monitoring the closing of lift doors. Choose by fork and contacts.
Z70 EMAS – lift door contact. Technical parameters, application and compatibility check.
Z73 EMAS – lift door contact. Technical parameters, application and compatibility check.
Z74 EMAS – lift door contact. Technical parameters, application and compatibility check.
Z71 EMAS – lift door contact. Technical parameters, application and compatibility check.
Z72 EMAS – lift door contact. Technical parameters, application and compatibility check.
Prices include the recycling fee.
When selecting a lift door component, it is important to distinguish an individual part from a complete functional assembly. The fork, base and their fastening method must match the equipment documentation. Similar dimensions or the same colour are no proof of interchangeability. A correct replacement starts with identifying the original designation and the role of the contact in the specific door system.
The public TECHNOLINE listing includes forks Z70 and Z73 as well as bases Z71 and Z72. EMAS product sheet Z71 confirms a single-entry base of a lift door switch. Suitable pairing is decided by the assembly documentation, not by the order of items in the catalogue.
For ordering, prepare the code of both cooperating parts, the mounting drawing, the direction of movement and the required electrical properties. If the marking of the old part is illegible, add photos and dimensions for professional cross-referencing. Treat a photo alone as supporting information: it will not show all contact properties or internal changes between variants.
In the mounting sketch, mark the initial position, the final door position and the insertion axis. During the check, separate lateral misalignment from insufficient insertion depth. These are two different quantities; adjusting one may not remove the problem of the other. Also document which mechanical parts determine the end of movement and what adjustment options remain after tightening.
If the repair affects the fastening, include both parts in the subsequent check. Replacing a worn fork does not by itself prove the correct condition of the original base. For service, it is useful to keep a history of replacements and adjustments for each door, so that recurring problems are not solved each time just with a new electrical component.
For a practice pair, let us design a nominal insertion of 8.0 mm. The model position of the stop may take away 0.4 mm and the bracket position another 0.3 mm. The smallest insertion is therefore 7.3 mm. With the opposite combination of deviations it reaches 8.7 mm. The designer must compare both extreme values with the prescribed operating range of the specific product.
If, in addition, an irreversible outward shift of the bracket by 0.5 mm occurs in the model, the interval changes to 6.8 to 8.2 mm. These are not parameters of Z71 nor instructions for adjusting a lift. The calculation illustrates why the check does not look only at the nominal position of a newly assembled door, but also at possible changes in the mechanics.
For Z71 the manufacturer states 2 A at 230 V AC in category AC‑15 and protection IP20. The data refer to this product under specified conditions. They do not prove the degree of protection of the finished installation or permitted switching of any load. Assess the parameters of another base separately.
Such a function cannot be derived from the name lift switch. The required locking and electrical monitoring must correspond to the documented design of the entire equipment.
No. You need to confirm the correct pair, the working movement and the electrical version, and carry out the prescribed check after the repair.
For orientation in the wider range, see Limit Switches. The context of protective functions is offered by the category Safety Limit Switches; do not regard products from another branch as a lift replacement without documentation.
We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.
Choose which cookies we may use. You can change your choice at any time.
They keep the cart contents, your login and selected language, and protect forms from abuse. An order cannot be completed without them, so they are used even without consent.
Google Analytics shows us traffic and behaviour on the website in aggregated form. This tells us which pages are not working for people. We do not identify anyone from this data.