Hinge Switches

EMAS hinge safety switches built into the hinge of a protective door monitor its opening. Choose by contacts and mounting.

Filters
Found 8 products
OUR TIP

L5K23BEM621, EMAS, L5, hinge safety switch, plastic body, rotary tubular hinge actuator, 1 NC + 1 NO, slow action, IP65

Cat. no.: L5K23BEM621

L5K23BEM621 EMAS – hinge safety switch, L5, rotary tubular hinge actuator, 1 NC + 1 NO, slow action. Technical parameters, application and compatibility check.

On request
9,87 €
excl. VAT · 11,94 € incl. VAT
OUR TIP

L5K25BEM621, EMAS, L5, hinge safety switch, plastic body, rotary tubular hinge actuator, 2 NC + 1 NO, slow action, IP65

Cat. no.: L5K25BEM621

L5K25BEM621 EMAS – hinge safety switch, L5, rotary tubular hinge actuator, 2 NC + 1 NO, slow action. Technical parameters, application and compatibility check.

On request
11,92 €
excl. VAT · 14,42 € incl. VAT
OUR TIP

L5K27BEM621, EMAS, L5, hinge safety switch, plastic body, rotary tubular hinge actuator, 1 NC + 2 NO, slow action, IP65

Cat. no.: L5K27BEM621

L5K27BEM621 EMAS – hinge safety switch, L5, rotary tubular hinge actuator, 1 NC + 2 NO, slow action. Technical parameters, application and compatibility check.

On request
11,92 €
excl. VAT · 14,42 € incl. VAT

Prices include the recycling fee.

Hinge Switches

A hinge switch monitors the movement of a hinged guard through the rotation of its mechanism. The basis of a correct design is an unambiguous relationship between the door movement and the switch movement. It is not enough that both parts react in some way during a manual test. You need to know how the initial opening is transmitted, what the play in the connection affects and whether the mounting maintains the same behaviour after the hinges are adjusted.

Selection by guard design

The public TECHNOLINE range includes L5K23LEM621. A separate EMAS sheet describes it as a hinge switch with a plastic body and slow-action contacts 1NO + 1NC. The detailed switching sequence must be assessed from the documentation of the specific variant.

Mark the actual door axis, opening direction, method of transmitting rotation and space for the switch on the drawing. When comparing left-hand, right-hand or bidirectional versions, also determine the view relative to which the manufacturer describes the direction. A verbal designation without a drawing can be misleading when viewed from the opposite side. Therefore keep the exact code in the order and attach the assembly orientation.

Play cannot be removed by electrical wiring

To check the mechanics, separate three possible contributions: zero offset during mounting, play in the transmission connection and change of door position under load. Each requires a different solution. An offset setting can be corrected by adjustment, a loose connection needs mechanical work and a flexing guard needs a design or mounting change.

After mounting, note the position of the closed guard and the behaviour during slow opening and closing. Carry out the check under the conditions specified by the design. Photos of marked joints and a record of the settings make future diagnostics easier. When replacing the door, do not automatically rely on the original adjustment, even if the hinge spacing has remained the same.

Author's example: uncertainty of angular setting

In a model design, the monitored change should occur around an angle of 2.0°. For the calculation, consider a mounting uncertainty of ±0.3°, connection play of ±0.4° and further scatter of ±0.2°. With a conservative sum of absolute deviations we get ±0.9°, so the interval is 1.1 to 2.9°.

After a mechanical modification, the model connection play is reduced to ±0.1°. The total deviation is then ±0.6° and the interval 1.4 to 2.6°. All figures are the author's own; they are not the switching angle, tolerance or repeatability of L5K23LEM621. Nor does the result determine the permitted opening of the protective guard.

The example shows how improving one mechanical link affects the whole assembly. Merely resetting the nominal angle shifts the interval but does not narrow it. It is therefore useful to first find the origin of the scatter and only then choose the final setting.

Mistakes and FAQ

Can the switch carry the door instead of a hinge?

Do not assume a load-bearing function without explicit documentation for the specific design. In the design, determine which parts carry the weight and which only sense the position.

Is it enough to check electrical continuity after a repair?

Continuity is only a partial check. Also verify the transmission of movement, reference positions and the required machine response. Safety suitability, PL or SIL do not arise merely from using a hinge component.

For guards with a separate actuating counterpart, compare Key-Operated Safety Switches - without Electrical Locking. A broader context of mounting and choice of protective function is offered by the category Safety Limit Switches.

Cookies on this website