Phone +420 774 723 123 Cart · 0 · empty

Valves

3/2, 5/2 and 5/3 pneumatic directional valves with electrical, pneumatic or manual actuation. Choose by function, rest position, port and coil voltage.

Filters
Found 174 products

SY3160-5LOU-C4-Q, SMC, solenoid valve

Cat. no.: SY3160-5LOU-C4-Q

SY3160-5LOU-C4-Q, SMC, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
63,84 €
excl. VAT · 77,25 € incl. VAT

SY3160-5LOU-C6-Q, SMC, solenoid valve

Cat. no.: SY3160-5LOU-C6-Q

SY3160-5LOU-C6-Q SMC – solenoid valve. When selecting, verify the connection, size and other parameters of the specific variant.

On request
64,45 €
excl. VAT · 77,99 € incl. VAT

VT317-5DZ-02F-Q, SMC, solenoid control valve

Cat. no.: VT317-5DZ-02F-Q

VT317-5DZ-02F-Q, SMC, solenoid control valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
65,11 €
excl. VAT · 78,78 € incl. VAT

SV2100-5FU, solenoid pilot-operated valve, SMC

Cat. no.: SV2100-5FU

SV2100-5FU, solenoid pilot-operated valve, SMC

On request
65,11 €
excl. VAT · 78,78 € incl. VAT

SY5120-5DO-C8F-Q, SMC, solenoid pilot-operated valve

Cat. no.: SY5120-5DO-C8F-Q

SY5120-5DO-C8F-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
66,34 €
excl. VAT · 80,27 € incl. VAT

SY7120-5YOE-02F-Q, SMC, solenoid pilot-operated valve

Cat. no.: SY7120-5YOE-02F-Q

SY7120-5YOE-02F-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
66,54 €
excl. VAT · 80,51 € incl. VAT

VUVS-LK20-M52-AD-G18-1C1-S, Festo, solenoid valve. 8043214

Cat. no.: VUVS-LK20-M52-AD-G18-1C1-S

VUVS-LK20-M52-AD-G18-1C1-S, Festo, solenoid valve. 8043214. A solenoid valve electrically controls the direction of compressed air flow.

On request
68,38 €
excl. VAT · 82,74 € incl. VAT

SY313-5MOU-C6-Q, solenoid pilot-operated valve, SMC

Cat. no.: SY313-5MOU-C6-Q

SY313-5MOU-C6-Q, solenoid pilot-operated valve, SMC

On request
68,38 €
excl. VAT · 82,74 € incl. VAT

SYJ7123-5MOU-01F-Q, SMC, solenoid pilot-operated valve

Cat. no.: SYJ7123-5MOU-01F-Q

SYJ7123-5MOU-01F-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
68,79 €
excl. VAT · 83,24 € incl. VAT

SY3240-5LO-Q, SMC, solenoid pilot-operated valve

Cat. no.: SY3240-5LO-Q

SY3240-5LO-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
68,79 €
excl. VAT · 83,24 € incl. VAT

SY7120-4YO-02F-Q, SMC, solenoid valve

Cat. no.: SY7120-4YO-02F-Q

SY7120-4YO-02F-Q, SMC, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
68,79 €
excl. VAT · 83,24 € incl. VAT

SY7120-3YO-02F-Q, SMC, solenoid pilot-operated valve

Cat. no.: SY7120-3YO-02F-Q

SY7120-3YO-02F-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
69,20 €
excl. VAT · 83,73 € incl. VAT

SY7120-5YO-C10F-Q, SMC, solenoid pilot-operated valve

Cat. no.: SY7120-5YO-C10F-Q

SY7120-5YO-C10F-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
70,02 €
excl. VAT · 84,72 € incl. VAT

SYJ5140-5MOZ-Q, SMC, solenoid pilot-operated valve

Cat. no.: SYJ5140-5MOZ-Q

SYJ5140-5MOZ-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
70,43 €
excl. VAT · 85,22 € incl. VAT

SY5120-5LOU-C4F-Q, SMC, solenoid pilot-operated valve

Cat. no.: SY5120-5LOU-C4F-Q

SY5120-5LOU-C4F-Q, SMC, solenoid pilot-operated valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
70,43 €
excl. VAT · 85,22 € incl. VAT

AD402-N02C-6Z-A, SMC, condensate drain valve

Cat. no.: AD402-N02C-6Z-A

AD402-N02C-6Z-A, SMC, condensate drain valve. The air preparation element filters, regulates or otherwise prepares the compressed air for the pneumatic system.

On request
71,25 €
excl. VAT · 86,21 € incl. VAT

SY5120-5LOU-C6F-Q, solenoid valve, SMC

Cat. no.: SY5120-5LOU-C6F-Q

solenoid 5/2 valve; monostable; voltage: 24V DC; SMC

On request
71,66 €
excl. VAT · 86,71 € incl. VAT

SY9120-5YO-03F-Q, SMC, solenoid valve

Cat. no.: SY9120-5YO-03F-Q

SY9120-5YO-03F-Q, SMC, solenoid valve. A solenoid valve electrically controls the direction of compressed air flow.

On request
71,66 €
excl. VAT · 86,71 € incl. VAT

SY7120-5LOU-C8F-Q, SMC, solenoid 5/2 valve, monostable, 24 V DC, tube Ø 8 mm

Cat. no.: SY7120-5LOU-C8F-Q

SY7120-5LOU-C8F-Q, SMC, solenoid 5/2 valve, monostable, 24 V DC, tube Ø 8 mm. A solenoid valve electrically controls the direction of compressed air flow.

On request
72,64 €
excl. VAT · 87,89 € incl. VAT

SY7120-5YO-C8F-Q, solenoid pilot-operated valve, SMC

Cat. no.: SY7120-5YO-C8F-Q

SY7120-5YO-C8F-Q, solenoid pilot-operated valve, SMC

On request
72,89 €
excl. VAT · 88,19 € incl. VAT

VQZ215K-5YB1-Q, solenoid pilot-operated valve, SMC

Cat. no.: VQZ215K-5YB1-Q

VQZ215K-5YB1-Q, solenoid pilot-operated valve, SMC

On request
72,89 €
excl. VAT · 88,19 € incl. VAT

SY7120-5YOD-02F-Q, solenoid valve, SMC

Cat. no.: SY7120-5YOD-02F-Q

solenoid valve; voltage: 24VDC; SMC

On request
72,89 €
excl. VAT · 88,19 € incl. VAT

SY513-4YO-C6F-Q, SMC, solenoid pilot-operated valve with threads in body

Cat. no.: SY513-4YO-C6F-Q

SY513-4YO-C6F-Q, SMC, solenoid pilot-operated valve with threads in body. A solenoid valve electrically controls the direction of compressed air flow.

On request
72,89 €
excl. VAT · 88,19 € incl. VAT

VQC2101NR-51, solenoid pilot-operated valve, SMC

Cat. no.: VQC2101NR-51

VQC2101NR-51, solenoid pilot-operated valve, SMC

On request
73,21 €
excl. VAT · 88,59 € incl. VAT

Prices include the recycling fee.

Pneumatic directional valves

A directional valve controls the connection of the supply, working paths and exhaust according to its functional symbol. For selection, you need the required state of the actuator and the behaviour when the command and energy change. The number of ways alone does not describe the rest or centre position.

Selection data Valves

Step What to document
Identification symbol, number of ways and positions
Operating requirements pilot pressure and electrical actuation
Acceptance circuit switching and exhaust

The range here includes TE3V/TE4V, SMC SY, VQ, VX and VDW series as well as Festo valves. For a service replacement, start with the function of the original circuit and the full part code. Similar-looking bodies may represent different circuits.

Number of positions and rest state

At TECHNOLINE, they represent TE3V310-10-NC-DC24V-LD a TE3V310-10-NO-DC24V-LD two rest variants 3/2. NC means the supply path to the working output is closed in the home state, NO means it is open. When selecting, therefore, draw the required media path with the electrical command disconnected.

TE4V310-10-NC-DC24V-LD is 5/2, while TE4V330C-10-NC-DC24V-LD is a 5/3 with a closed centre position. NC or NO alone is not a complete description of all channels of a 5-way valve. For example, Festo VUVS-L25-P53E-MD-G14-F8-1C1 uses an exhaust centre. Read the specific arrangement from the symbol; do not create a replacement simply by counting the coils.

Pilot pressure and medium are separate criteria

Festo datasheet 8042543 explicitly states pilot operation and internal pilot air supply. For your own selection sheet, therefore, record the pressure of the working branch and the requirements of the pilot stage separately. For an external pilot, verify its separate supply according to the diagram. Electrical voltage alone does not confirm that the pneumatic conditions for switching are met.

For 2-way valves, the medium and the pressure differential are further distinguished. SMC manual VQ20/30 requires a minimum differential of 0.01 MPa for opening. Catalogue VX21/22/23 separates the highest system pressure from the highest working pressure differential. Record both input values in the comparison; a high pressure upstream of the valve alone is not enough.

Model calculation: pressure upstream of the valve is insufficient

For our own example, let us assume pressures measured against the same reference: 0.43 MPa upstream of the valve and 0.425 MPa downstream. The difference is Δp = 0.43 − 0.425 = 0.005 MPa, i.e. 5 kPa. With our own design requirement of at least 20 kPa, this model situation does not comply, even though there is significant overpressure at the inlet.

If, in the second model situation, the outlet pressure drops to 0.40 MPa, the difference increases to 30 kPa. This only meets the considered pressure differential condition. The example does not determine the flow rate, opening time or suitability of a specific valve. The actual values must be determined during the working sequence, not taken from the compressor setting.

Mounting and targeted diagnostics

Before disconnecting, ensure a de-energised and depressurised state. The VQ20/30 manual requires a functional test and leak check after mounting. For this series, it also points out that a locked manual override can change the response to switching off the electrical command. Therefore, include the manual override position in the check before start-up.

As our own diagnostic procedure, record the command, voltage and pressure conditions at the same time. Compare a standalone cycle with simultaneous operation of other consumers. If the problem occurs only in the assembly, add to the check Plates for terminals and the connected line. Look up the electrical variant via Accessories, always according to the full code.

FAQ

Is the 5/2 valve a replacement for 5/3?

This cannot be assumed without changing the required function. Also include the behaviour of the third position in the comparison and verify whether the working sequence actually needs it.

Can the permitted medium be determined from the series designation?

Only in combination with the exact variant and its documentation. For orientation in the whole range, use Pneumatic valves; inclusion of a product alone does not confirm its suitability for water, oil or vacuum.

Cookies on this website

We need technical cookies for the cart and checkout to work — these are always used. Analytics cookies show us which pages people look for and where they get lost, and help us improve the shop. We only use them if you allow it. More in the data processing policy.